Processor |
Number |
One SPARC T4 8-Core 2.85GHz processor |
Architecture |
SPARC V9 architecture, ECC Protected |
CPUs |
- 2.85GHz 8-Core
- 64 threads max
- Eight floating-point units
- On-chip Encryption Instruction Accelerators with direct non-privileged
support for
16 industry-standard cryptographic algorithms plus random number generation
in
each of the eight cores: AES, Camellia, CRC32c, DES, 3DES, DH, DSA,
ECC,
Kasumi, MD5, RSA, SHA-1, SHA-224, SHA-256, SHA-384, SHA-512
|
Cache memory |
Shared L3, 4MB cache and eight cores with private L2 128K cache |
Main Memory |
Capacities |
- Total DIMM slots: 16 on system board
- DIMM type: DDR3
- DIMM size: 4GB, 8GB or 16GB
- Minimum Configuation: 16GB (4 × 4GB)
- Maximum capacity: 256GB (16 × 16GB)
|
Standard Integrated Interfaces
|
Network |
4 × 10/100/1000 Mbps autonegotiating ports
Up to 2 .× optional 10 GbE XAUI connections |
Network Management |
One dedicated 10/100Base-T RJ-45 port Ethernet port |
Serial Management |
One dedicated RJ-45 port |
Remote Management |
Onboard system processor, running Integrated Lights
Out Manager (ILOM) 3.0 |
Graphics |
One DB-15 VGA connector |
USB |
Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports
|
PCI Expansion Slots |
- 6 low-profile PCI-Express 2.0 slots.
- Slots 0 and 3 support PCI-Express or 10Gbit Ethernet (XAUI) cards.
Slot # |
Physical |
Electrical |
0 |
x16 |
x8 |
1 |
x16 |
x8 |
2 |
x16 |
x8 |
3 |
x8 |
x8 |
4 |
x8 |
x8 |
5 |
x8 |
x8 |
|
Internal Mass Storage |
Disks |
- Up to eight 2.5-inch SAS drives
- 300GB or 600GB 2.5-inch SAS disk drives
- RAID 0, RAID 1, and RAID 1E support
|
DVD-ROM |
1 slimline SATA DVD +/-RW including two USB ports |
Solid State Drives |
Up to eight 100GB or 300GB solid state drives |
Power Supplies |
2 × 1200 Watt, hot-swappable, N+1
redundant power supply units (PSU) |
Environment |
Input Voltage |
100 - 120 VAC, 50-60Hz
200 - 240 VAC, 50-60Hz |
Input Current |
8.57 A @ 100 VAC max
4.2 A @ 200 VAC max
|
Input Power |
771 W @ 100 VAC max
762 W @ 200 VAC max |
Heat Output |
2317 BTU/hr, 145 cfm max |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)
Note: Above 900m (3000 ft), decrease maximum temperature as altitude
increase, 1° C/300m (1.6° F/1000ft)
|
Humidity |
Operating: 10% to 90% relative humidity noncondensing, 27°
C (80.6° F) maximum wet bulb
Nonoperating: 93% relative humidity noncondensing, 38° C (104°
F) maximum wet bulb |
Altitude |
Operating: up to 3000m (10000 ft.)
Nonoperating: up to 12000m (40000 ft.) |
Vibration |
Operating: 0.15 G (vertical), 0.10 G (horizontal), 5 ? 500 Hz,
swept-sine
Nonoperating: 0.5 G (vertical), 0.25 G (horizontal), 5 ? 500 Hz,
swept-sine
|
Shock |
Operating: 3Gs, 11ms half-sine
Nonoperating: 1-inch roll-off free fall, front-to-back rolling direction,
25mm threshold height at 0.75 m/s impact velocity |
Acoustic Noise |
Operating/Idling: 61.2 dBA (LwAd, 1B = 10dB)
Operating/Idling: 61.5 dBA (LpAm, bystander positions) |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations,
IEC825-1, 2, CFR21 part 1040, CNS14336 |
RFI/EMI |
EN55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ3548
Class A, CNS 13438 Class A, KSC 5858 Class A, EN61000-3-2, EN61000-3-3 |
Immunity |
EN55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5,
IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 |
Regulatory Markings |
CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL,
UL/Smark |
European Union Directives |
2006/95/EC (73/23/EEC) Low Voltage Directive, 2004/108/EC (89/336/EEC)
EMC Directive, 2002/96/EC Waste Electrical and Electronic Equipment (WEEE)
Directive, 2002/95/EC Restriction of Hazardous Substances (RoHS) Directive
|
Dimensions and Weight |
Height |
88.6 mm (3.49 in.) |
Width |
425.5 mm (16.75 in.) |
Depth |
714.5 mm (28.13 in.) |
Weight |
Appx 27.2 kg (60 lbs), without rackmount hardware |
Clearance
and Service Access |
Front |
910 mm (36 in.) |
Rear |
910 mm (36 in.) |