Sun Microsystems, Inc.   Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun SPARC® Enterprise M3000 Server: Hardware Specifications

 

Processor
Number One CPU
Architecture SPARC64 VII: 2.52GHz or 2.75GHz Dual or Quad Core processor, SPARC V9, ECC Protected
SPARC64 VII+: 2.86GHz Dual or Quad Core processor, SPARC V9, ECC Protected
Cache memory SPARC64 VII: 5MB Shared Level 2 on Chip Cache, 64KB I-Cache and 64KB D-Cache Level
SPARC64 VII+: 5.5MB Shared Level 2 on Chip Cache, 64KB I-Cache and 64KB D-Cache Level
Main Memory
Capacities

8GB (using 1GB DDR2 DIMMS) to 64GB (using 8GB DDR2 DIMMs), 8 slots per system. DIMM sizes: 1GB, 2GB, 4GB and 8GB.

Standard Interfaces
Ethernet 4 × integrated Gigabit Ethernet ports also 2 × 10/100 ethernet ports for accessing CLI and browser based interface on Extended System Control Facility (XSCF)
PCI-X / PCI-Express 4 × X8 PCI-E Slots
Serial One RJ45
USB One port on XSCF that field engineer can use to download hardware information
SAS One external SAS port (two-lane)
Internal Mass Storage
Disks Up to 4 internal 146GB SAS Disk Drives
DVD-ROM 1 DVD-RW
Tape None
Power Supplies
Type 1 or 2 × 100-240 VAC, 565W, (50 Hz/60 Hz)
Output 600 Watts (2 power cords)
Environment
AC Power 100-240 VAC
DC Power ~48V/~60V
Input power 100 VAC to 120 VAC
200 VAC to 240 VAC
Power Draw 470W to 505W (depending on CPU's and system configuration)
Maximum Current 24.0A at 100 127 VAC, 12A / cord
12.0A at 200 240 VAC, 12A / cord
Heat output 2150 BTU/hr
Temperature Operating: 5° C to 35° C (41° F to 95° F) *
Nonoperating: -20° C to 60° C (-4° F to 140° F) *
Optimal: 21° C to 23° C (70° F to 74° F)
Humidity Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 8% to 80% relative humidity, noncondensing
Optimal: 45% to 50% relative humidity, noncondensing
Altitude Operating: Up to 3048m (10000 ft)
Nonoperating: 12000m (40000 ft)
* - derated 2° C for every 1km up to 3km
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL, WEEE and Chinese RoHS
Safety CSA60950-1-03, UL60950-1, IEC60950-1, 1(2001), GB4943-2001 Scheme with all national deviations
Ergonomics N/A
RFI/EMI FCC part-15, EN55022/CISPR22, VCCI, AS/NZS CISPR 22, EN 300 386, EN61000-3-2, EN61000-3-3, JISC61000-3-2, KN22, GB9254, GB17625
Immunity EN55024, EN 300 386, KN24
Regulatory Markings CE, FCC, VCCI, CSA C/US
Dimensions and Weights
Height 8.7 cm (3.43 in)
Width 44 cm (17.33 in)
Depth 65.7 cm (25.87 in)
Weight 22kg (48.50 lbs)
Power Cord 1 - 2, 4m (13 ft) *
Americas, Japan, & Taiwan: NEMA L5-15 125V 15A, NEMA L6-20 250V 20A
All other locations except Japan & Taiwan: IEC 60309 16A 250V, 3PIN with IEC60309 C20
* - 2 power cords required for redundancy
Clearance and Service Access
Front 91.4cm (36 in)
Rear 91.4cm (36 in)
Right none - front to back cooling
Left none - front to back cooling
Top 91.4cm (36 in)
Airflow Front to back - 8.5 cubic meters per minute (300 cfm) in normal operating conditions
Rack Mounting
Sun Rack 1000-38, Sun Rack 1000-42, Sun Rack 900

  Copyright � 2012 Sun Microsystems, Inc.  All rights reserved.