Processor
Number Two Intel 8-core
Architecture Type: 8-Core Intel Xeon E5-2658 (20MB Cache, 8 GT/s QPI, 2.1 GHz, 95W)
Cache memory 32KB instruction and 32KB data L1 cache per core
256KB unified (data and instruction) L2 cache per core
20MB shared inclusive L3 cache per processor
Main Memory
Capacities DIMM slots per CPU socket: 8
Total DIMM slots (when 2 CPU's are installed): 16
DIMM type: DDR3-1600 Registered DIMMs
DIMM size: 8GB, 16GB
Maximum capacity: 256 GB (when configured with 16GB DIMMs)
Standard Integrated Interfaces
Network Four 10/100/1000Base-T Ethernet ports
Network Management One 10/100Base-T Ethernet port
Serial Management One TIA/EIA-232-F asynchronous RJ45 port
SAS Four-channel SAS Interface (with SFF-8088 connector), internal access only
USB (2.0)
Front: 2
Rear: 2
Internal: 2
Video
One VGA Video port (HD-15)
Alarms
Four fail-safe  DB-15 dry contact  (critical, major, minor and user)
Expansion Bus Six PCIe 3.0 LP slots - six (6) x8-lane slots
Note: Slot 1, the lower slot of Riser 1 is reserved for the Sun Storage 6 Gb SAS PCIe RAID HBA, Internal card. This is a configuration requirement.
Internal Mass Storage
Option 1
DVD-R/W, six 300GB or 600GB 2.5in 10K RPM SAS disks.
Option 2
No DVD-R/W, Up to eight 300GB or 600GB 2.5in 10K RPM SAS disks.
DVD-ROM One 8x SATA DVD-Writer/24x CD-Writer
Power Supplies
Two 660W (1+1) hot-swappable DC or Two 760W hot-swappable AC
Note: To ensure redundant operation of the power supplies, the two power inputs should be connected to separate power sources. 
DC Power
-48V DC or -60V DC
AC Power
100-240V AC, 50-60 Hz
Environment
Temperature Operating: 5° C to 45° C (41° F to 113° F)/Short term: 5° C to 55° C (23° F to 131° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 5% to 85% relative humidity noncondensing, max wet bulb.  Short term: 5% to 90% relative humidity noncondensing, but not to exceed 0.024kg water/kg dry air (0.053 lbs. water 2.205 lb. dry air)
Nonoperating: up to 93% relative humidity noncondensing, 40° C (104° F) max wet bulb
Altitude Operating: Meets NEBS 4,000m (13,123 ft.)
Nonoperating: up to 12,000m (39,370 ft.)
Acoustic noise Operating/Idling Acoustic Noise less than 7.2B @ 25° C (LwAd, 1B=10dB)
Regulations
Meets or exceeds the following requirements:
Safety UL 60950-1, EN60950-1, IEC60950-1 (Evaluated to all CB countries), CSA C22.2 No. 60950-1-07, IEC825-1, 2, and CFR21 part 1040
NEBS NEBS Level 3 certified by Telcordia
EMI EN55022 Class A, CISPR22 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ CISPR22 Class A, CNS 13438 Class A, EN300386 for Telecommunications Centers and for Other Than Telecommunications Centers
EMC (immunity) EN55024, EN61000-3-2, EN61000-3-3, EN300386:2010 for Telecommunications Centers and for Other Than Telecommunications Centers.
Regulatory Markings
CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, KCC, UL/cUL, S-mark, CCC
Seismic
GR-63-CORE requirements for earthquake zone 4
Other
Restriction of Hazardous Substances (RoHS) Directive and Waste Electrical and Electronics Equipment (WEEE) Directive
Dimensions and Weight
Height 87 mm (3.43 in.) 2 RU
Width 445 mm (17.52 in.) including mounting ears
Depth maximum to PSU handles: 527.8 mm (20.78 in.)
maximum of rear I/O: 501.4 mm (19.74 in.)
Weight Approximate (without PCI cards)
18.5 kg (40.8 lb.)
Rack Mounting
Rack Units
2
Rack Kits Available
  • 19-inch 2-post
  • 19-inch 2-post (slide rail)
  • 23-inch 2-post
  • 600mm x 600mm and
  • 19-inch 4-post slide adjustable1
1 The slide kit includes hardware that enables mounting to any of the following types of rack rails:
  • 6 mm threaded holes
  • #10-32 threaded holes
  • #10 threaded holes
These must be compliant racks which have mounting depths of 27-30 inches.