Processor |
Number |
Two Intel 8-core |
Architecture |
Type: 8-Core Intel Xeon E5-2658 (20MB Cache, 8 GT/s QPI, 2.1 GHz, 95W)
|
Cache memory |
32KB instruction and 32KB data L1 cache per core
256KB unified (data and instruction) L2 cache per core
20MB shared inclusive L3 cache per processor
|
Main Memory |
Capacities |
DIMM slots per CPU socket: 8
Total DIMM slots (when 2 CPU's are installed): 16
DIMM type: DDR3-1600 Registered DIMMs
DIMM size: 8GB, 16GB
Maximum capacity: 256 GB (when configured with 16GB DIMMs)
|
Standard
Integrated Interfaces |
Network |
Four 10/100/1000Base-T Ethernet ports |
Network Management |
One 10/100Base-T Ethernet port |
Serial Management |
One TIA/EIA-232-F asynchronous RJ45 port |
SAS |
Four-channel SAS Interface (with SFF-8088 connector), internal access only |
USB (2.0)
|
Front: 2
Rear: 2
Internal: 2
|
Video
|
One VGA Video port (HD-15)
|
Alarms
|
Four fail-safe DB-15 dry contact (critical, major, minor and user)
|
Expansion Bus |
Six PCIe 3.0 LP slots - six (6) x8-lane slots
Note: Slot 1, the lower slot of Riser 1 is reserved for the Sun Storage 6 Gb SAS PCIe
RAID HBA, Internal card. This is a configuration requirement.
|
Internal Mass Storage |
Option 1
|
DVD-R/W, six 300GB or 600GB 2.5in 10K
RPM SAS disks. |
Option 2
|
No DVD-R/W, Up to eight 300GB or 600GB 2.5in 10K RPM
SAS disks.
|
DVD-ROM |
One 8x SATA DVD-Writer/24x CD-Writer
|
Power Supplies |
Two 660W (1+1)
hot-swappable DC or Two 760W hot-swappable AC
Note: To ensure redundant
operation of the power supplies, the two power inputs should be
connected to separate power sources.
|
DC Power
|
-48V DC or -60V DC
|
AC Power
|
100-240V AC, 50-60 Hz
|
Environment |
Temperature |
Operating: 5° C to 45° C (41° F to
113° F)/Short term: 5° C to 55° C (23° F to 131° F)
Nonoperating: -40° C to 70° C (-40° F to
158° F)
|
Humidity |
Operating: 5% to 85% relative humidity noncondensing,
max wet bulb. Short term: 5% to 90% relative humidity
noncondensing, but not to exceed 0.024kg water/kg dry air (0.053 lbs.
water 2.205 lb. dry air)
Nonoperating: up to 93% relative humidity noncondensing,
40° C (104° F) max wet bulb
|
Altitude |
Operating: Meets NEBS 4,000m (13,123 ft.)
Nonoperating: up to 12,000m (39,370 ft.) |
Acoustic noise |
Operating/Idling Acoustic Noise less than 7.2B @ 25° C (LwAd, 1B=10dB) |
Regulations
Meets or exceeds the following
requirements: |
Safety |
UL 60950-1, EN60950-1, IEC60950-1 (Evaluated to all CB countries), CSA C22.2 No. 60950-1-07, IEC825-1, 2, and CFR21 part 1040 |
NEBS |
NEBS Level 3 certified by Telcordia |
EMI |
EN55022 Class A, CISPR22 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ CISPR22 Class A, CNS 13438 Class A, EN300386 for Telecommunications Centers and for Other Than Telecommunications Centers
|
EMC (immunity) |
EN55024, EN61000-3-2, EN61000-3-3, EN300386:2010 for Telecommunications Centers and for Other Than Telecommunications Centers. |
Regulatory Markings
|
CE, FCC, ICES-003, C-tick, VCCI,
GOST-R, BSMI, KCC, UL/cUL, S-mark, CCC
|
Seismic
|
GR-63-CORE requirements for earthquake zone 4
|
Other
|
Restriction of Hazardous Substances (RoHS) Directive and Waste Electrical and Electronics Equipment (WEEE) Directive
|
Dimensions and Weight |
Height |
87 mm (3.43 in.) 2 RU
|
Width |
445 mm (17.52 in.) including mounting ears |
Depth |
maximum to PSU handles: 527.8 mm (20.78 in.)
maximum of rear I/O: 501.4 mm (19.74 in.)
|
Weight |
Approximate (without PCI cards)
18.5 kg (40.8 lb.)
|
Rack Mounting |
Rack Units
|
2
|
Rack Kits Available |
- 19-inch 2-post
- 19-inch 2-post (slide rail)
- 23-inch 2-post
- 600mm x 600mm and
- 19-inch 4-post slide adjustable1
|
1 The slide kit includes hardware that
enables mounting to any of the following types of rack rails:
- 6 mm threaded holes
- #10-32 threaded holes
- #10 threaded holes
These must be compliant racks which have mounting
depths of 27-30 inches. |