Sun Microsystems, Inc.   Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Netra SPARC[tm] T4-2 Server: Hardware Specifications

Processor
Number Two SPARC T4 8-Core 2.85GHz processors
Architecture SPARC V9 architecture, ECC Protected
CPUs
  • 2.85GHz 8-Core
  • 64 threads per CPU, 128 threads max
  • Up to eight floating-point units
  • Dual integrated multithreaded 10 GbE XAUI channels per processor
  • On-chip Encryption Instruction Accelerators with direct non-privileged support for
    16 industry-standard cryptographic algorithms plus random number generation in
    each of the eight cores: AES, Camellia, CRC32c, DES, 3DES, DH, DSA, ECC, Kasumi, MD5, RSA, SHA-1, SHA-224, SHA-256, SHA-384, SHA-512
Cache memory
  • Shared L3, 4MB cache
  • Dedicated128KB level 2 cache per core
Main Memory
Capacities
  • Total DIMM slots: 32 - 8 slots per memory riser, 2 memory risers per CPU
  • DIMM type: DDR3
  • DIMM size: 4GB, 8GB or 16GB
  • Minimum Configuation: 64GB. (16 × 4GB). 16 slots is minimum slot configuration.
  • Maximum capacity: 512GB (32 × 16GB)
Standard Integrated Interfaces
Network 4 × 10/100/1000 Base-T Ethernet ports
Network Management One dedicated 10/100Base-T RJ-45 port Ethernet port
Serial Management One dedicated RJ-45 port
Remote Management Onboard service processor, running Integrated Lights Out Manager (ILOM)
Graphics One DB-15 VGA connector
USB Front: 2 USB 2.0 Ports
Expansion Slots
  • Ten low-profile PCI-Express 2.0 slots
    • Slots 0-7 requiring low-height brackets
    • Slots 8-9 requiring full-height bracket
    • Four x16 mechanical slots operating at x8
    • Four x8 mechanical slots operating at x8
    • Two x8 mechanical slots operating at x4
    • Cards with a low height bracket will not fit in slots 8 and 9
  • One XAUI network module slot
Internal Mass Storage
Disks
  • Up to eight 2.5-inch internal SAS drives
  • 300GB & 600GB 2.5-inch SAS disk drives
  • RAID 0 and RAID 1 support
DVD-ROM 1 slimline SATA DVD +/-RW
Power Supplies
Four 2N redundant AC or DC hot-swappable power supplies
Environment
Power Consumption Online power calculator
DC Power -48 V DC or -60 V DC
AC Power 100-240 V AC, 50-60 Hz
Temperature

Operating: 5° C to 45° C (41° F to 113° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)

Humidity Relative Humidity: 5% - 90%, non condensing, but not to exceed 0.024 Kg water/kg dry air (0.053 lb. water/2.205 lbs dry air)
Operating: 5% to 85% relative humidity noncondensing, but not to exceed 0.024 kg water/kg dry air (0.053 lb. water/2.205 lbs dry air)
Nonoperating: Up to 93% relative humidity noncondensing, 40° C (104° F) maximum wet bulb
Altitude

Operating: Meets NEBS 4000m (13,123 ft.) requirement
Nonoperating: Up to 12,000m (39,370 ft.)

Acoustic Noise Operating/Idling: 7.2B (LwAd: 1 B=10 db)
Regulations
Meets or exceeds the following requirements:
NEBS NEBS level 3 certified by Telecordia
Seismic GR-63-CORE requirements for Earthquake Zone 4
ETSI EN 300019-2-1,2,3, Class 1.2, 2.3, 3.1E (Except condensing humidity and rain)
Safety UL/CSA 60950-1, EN 60950-I, IEC 60950-I, IEC 60950-I CB Scheme with all national differences, IEC 825-1, 2, and CFR 21 Part 1040
RFI/EMC EN 55022/CISPR 22 Class A, FCC CFR 47 Part 15 Class A
Telecommunications EN 300 386
Immunity EN 55022/CISPR 24, EN 61000-3-2, EN 61000-3-3
Regulatory Markings CE, FCC, ICES-003, C-Tick, VCCI, GOST-R, MIC, UL/cUL, S-Mark, BSMI, CCC
Dimensions and Weight
Height 172.2 mm (6.86 in.)
Width 445 mm (17.18 in.)
Depth 530 mm (20.87 in.) max to PSU handles
505 mm (19.88 in.) max, to rear I/O
Weight Max: 33 kg (72.6 lbs) fully configured without PCI Express Cards
Clearance and Service Access
Front 910 mm (36 in.)
Rear 910 mm (36 in.)

  Copyright � 2012 Sun Microsystems, Inc.  All rights reserved.