Processor |
Number |
Two SPARC T4 8-Core 2.85GHz processors |
Architecture |
SPARC V9 architecture, ECC Protected |
CPUs |
- 2.85GHz 8-Core
- 64 threads per CPU, 128 threads max
- Up to eight floating-point units
- Dual integrated multithreaded 10 GbE XAUI channels per processor
- On-chip Encryption Instruction Accelerators with direct non-privileged
support for
16 industry-standard cryptographic algorithms plus random number generation
in
each of the eight cores: AES, Camellia, CRC32c, DES, 3DES, DH, DSA, ECC, Kasumi, MD5, RSA, SHA-1, SHA-224, SHA-256, SHA-384, SHA-512
|
Cache memory |
- Shared L3, 4MB cache
- Dedicated128KB level 2 cache per core
|
Main Memory |
Capacities |
- Total DIMM slots: 32 - 8 slots per memory riser, 2 memory risers per CPU
- DIMM type: DDR3
- DIMM size: 4GB, 8GB or 16GB
- Minimum Configuation: 64GB. (16 ×
4GB). 16 slots is minimum slot configuration.
- Maximum capacity: 512GB (32 × 16GB)
|
Standard Integrated Interfaces
|
Network |
4 × 10/100/1000 Base-T Ethernet ports |
Network Management |
One dedicated 10/100Base-T RJ-45 port
Ethernet port |
Serial Management |
One dedicated RJ-45 port |
Remote Management |
Onboard service processor, running Integrated
Lights Out Manager (ILOM) |
Graphics |
One DB-15 VGA connector |
USB |
Front: 2 USB 2.0 Ports
|
Expansion Slots |
- Ten low-profile PCI-Express 2.0 slots
- Slots 0-7 requiring low-height brackets
- Slots 8-9 requiring full-height bracket
- Four x16 mechanical slots operating at x8
- Four x8 mechanical slots operating at x8
- Two x8 mechanical slots operating at x4
- Cards with a low height bracket will not fit in slots 8 and 9
- One XAUI network module slot
|
Internal Mass Storage |
Disks |
- Up to eight 2.5-inch internal SAS drives
- 300GB & 600GB 2.5-inch SAS disk drives
- RAID 0 and RAID 1 support
|
DVD-ROM |
1 slimline SATA DVD +/-RW |
Power Supplies |
Four 2N redundant AC or DC hot-swappable power supplies
|
Environment |
Power Consumption |
Online power calculator |
DC Power |
-48 V DC or -60 V DC
|
AC Power |
100-240 V AC, 50-60 Hz
|
Temperature |
Operating: 5° C to 45° C (41° F to 113° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
|
Humidity |
Relative Humidity: 5% - 90%, non condensing, but not to exceed 0.024 Kg water/kg dry air (0.053 lb. water/2.205 lbs dry air)
Operating: 5% to 85% relative humidity noncondensing,
but not to exceed 0.024 kg water/kg dry air (0.053 lb. water/2.205 lbs dry air)
Nonoperating: Up to 93% relative humidity noncondensing, 40°
C (104° F) maximum wet bulb |
Altitude |
Operating: Meets NEBS 4000m (13,123 ft.) requirement
Nonoperating: Up to 12,000m (39,370 ft.)
|
Acoustic Noise |
Operating/Idling: 7.2B (LwAd: 1 B=10 db)
|
Regulations
Meets or exceeds the following requirements: |
NEBS |
NEBS level 3 certified by Telecordia |
Seismic |
GR-63-CORE requirements for Earthquake Zone 4 |
ETSI |
EN 300019-2-1,2,3, Class 1.2, 2.3, 3.1E (Except condensing humidity and rain) |
Safety |
UL/CSA 60950-1, EN 60950-I, IEC 60950-I, IEC 60950-I CB Scheme with all national differences, IEC 825-1, 2, and CFR 21 Part 1040
|
RFI/EMC |
EN 55022/CISPR 22 Class A, FCC CFR 47 Part 15 Class A
|
Telecommunications |
EN 300 386
|
Immunity |
EN 55022/CISPR 24, EN 61000-3-2, EN 61000-3-3
|
Regulatory Markings |
CE, FCC, ICES-003, C-Tick, VCCI, GOST-R, MIC, UL/cUL, S-Mark, BSMI, CCC
|
Dimensions and Weight |
Height |
172.2 mm (6.86 in.) |
Width |
445 mm (17.18 in.) |
Depth |
530 mm (20.87 in.) max to PSU handles
505 mm (19.88 in.) max, to rear I/O |
Weight |
Max: 33 kg (72.6 lbs) fully configured without PCI Express Cards |
Clearance
and Service Access |
Front |
910 mm (36 in.) |
Rear |
910 mm (36 in.) |