Processor |
Number |
One 4-Core SPARC T4 2.85GHz
or
One 8-Core SPARC T4 2.85GHz |
Architecture |
SPARC V9 architecture, ECC protected |
CPUs |
- 2.85GHz 4-core or 8-core SPARC T4
- 4-core 32 threads
- 8-core 64 threads
- up to 8 floating-point units
- On-chip encryption instruction accelerators with direct non-privileged
support for 16 industry standard cryptographic algorithms plus random
number generation in each of the 8-cores: AES, Camellia, CRC32c, DES,
3DES, DH, DSA, ECC, Kasumi, MD5, RSA, SHA-1,
SHA-224, SHA-256, SHA-384, SHA-512
|
Cache memory |
- Level 1: 16KB instruction cache and 16K data cache per core
- Level 2: 128KB cache per core
- Level 3: Shared 4MB cache
|
Main Memory |
Capacities |
- Total DIMM slots: 16 on system board
- DIMM type: DDR3
- DIMM size: 4GB, 8GB, and 16GB
- Maximum capacity: 256GB (16 × 16GB)
|
Standard Integrated Interfaces
|
Network |
4 × 10/100/1000 Mbps auto negotiating ports
Up to 2 optional 10 GbE XAUI connections |
Network Management |
One dedicated 10/100Base-T RJ-45 port
Ethernet port |
Serial Management |
One dedicated RJ-45 port |
Remote Management |
Onboard system processor, running Integrated
Lights Out Manager (ILOM) |
Graphics |
One HD-15 VGA connector |
USB |
Front:
2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports |
PCI Expansion Slots |
- Five PCIe Gen2 x8 slots (including support of
two full height half length PCIe cards slots and three low profile cards
slots or two XAUI)
- Slots 0 and 1 support PCI-Express or XAUI cards.
Slot # |
Physical |
Electrical |
0 |
x8 |
x8 |
1 |
x8 |
x8 |
2 |
x8 |
x8 |
3 |
x16 |
x8 |
4 |
x16 |
x8 |
|
Internal Mass Storage |
Disks |
- Up to four 2.5-inch SAS-2 disk drives
- 300GB or 600GB 2.5-inch SAS disk drives
- RAID 0 and RAID 1 support
|
DVD-ROM |
1 slimline SATA DVD Drive |
Power Supplies |
2 × 1200 Watt (Type A249A AC or
Type D204A DC), hot-swappable, N+1 redundant power supply units (PSU) |
Environment |
Input Voltage |
(AC) 100 - 240 VAC, 50-60Hz
(DC) -48 VDC or -60 VDC |
Temperature |
Operating: 5° C to 45° C (41° F to 113° F)
Short Term Operating: -5° C to 55° C (23° F to 131°
F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
|
Humidity |
Operating: 5% to 85% relative humidity noncondensing
Short Term Operating: 5% to 90% relative humidity noncondensing,
but not to exceed 0.024 kg water/kg dry air (0.053 lb. water/2.205 lbs.
dry air)
Nonoperating: 93% relative humidity noncondensing, 40° C, 104°
F) maximum wet bulb |
Altitude |
Operating: Meeets NEBS 4000m (13,123 ft) requirement
Nonoperating: up to 12000m (39,370 ft.) |
Seismic |
GR-63-CORE requirements for Earthquake Zone 4 |
Acoustic Noise |
Operating/Idling: 7.2 B (LwAd, 1B = 10dB) |
NEBS |
NEBS Level3 certified by Telecordia |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA C22.2 60950-1, 2nd Edition EN 60950-1, 2nd Edition,
IEC 60950-1 :2005 2nd Edition CB Scheme with all national differences, IEC
825-1,2 and CFR21 part 1040 |
RFI/EMI |
EN55022:2006+A1:2007/CISPR22:2005+A1:2005+A2:2006 EN300 386
V1.4.1 Class A, FCC CFR 47 Part 15 Class A |
Immunity |
EN55024/CISPR 24, EN 61000-3-2, EN 61000-3-3 |
Regulatory Markings |
CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL,
S-mark, CCC |
Other |
Restriction of Hazardous Substances (RoHS) labeled,
per WEEE (Waste Electrical and Electronics Equipment) Directive (2002/95/EC) |
Telecommunications |
EN 300 386 |
Dimensions and Weight |
Height |
87.1 mm (3.43 in.) |
Width |
445 mm (17.52 in.) including bezel |
Depth |
526 mm (20.71 in.) max to PSU handles |
Depth |
501 mm (19.72 in.) max to rear I/O |
Weight |