Exalytics In-Memory Machine X2-4: Hardware Specifications

Processor
Number 4 CPUs, each 10-Core
Architecture Type: Intel Xeon E7-4800 Processor Series
CPUs Intel 2.40GHz 10-Core Xeon E7-4870
Cache memory 256KB unified (data and instruction) Level 2 cache
12MB, 18MB or 24MB shared inclusive Level 3 cache
Main Memory
Capacities DIMM slots: 64 DIMM slots, 16 DIMMs per CPU
DIMM type: Registered DDR3-1333 DIMMs
Registered DDR3-1066 DIMMs
DIMM size: 16GB
Maximum capacity: 1TB
Standard Integrated Interfaces
Network Four Integrated 10/100/1000 Base-T Gigabit Ethernet
Network Management One 10/100 Base-T Ethernet management port
Serial Management One TIA/EIA-232-F asynchronous RJ45 serial port
USB Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports
Internal: 1 USB 2.0 Port
PCI Express 10 PCI Express 2.0 Slots
  • 2 slots (3 and 5) are either x8 or x16 electrical interface (x16 connector)
  • 6 slots are x8 PCI-E slots
  • 2 slots are x4 PCI-E slots
Note: Slots 3 and 5 operate as x16 interfaces only when an x16 capable card is
installed and the adjacent slot (4 or 6) is unpopulated.
Video One Rear and One Front HD15 VGA port
Graphics controller VGA 2D graphics controller embedded in Optional Service Processor
Support remote console at a resolution up to 1600x1200x16bits@60Hz
(1024x678 when viewed remotely via ILOM RKVMS)
Note: The rear VGA port supports VESA Device Data Channel for monitor identification.
Internal Mass Storage
Disks Up to 6 hot-swappable disks

Drive Type
Density
Speed
Form Factor
SAS
600GB
10,000 RPM
2.5"

Power Supplies
Dual redundant, hot swappable power supplies
2060W Capacity (From 200 Volts to 240 Volts)
Environment
AC power 100-127 VAC for 2 CPU's
200-240 VAC for 2 or 4 CPU's
50/60 Hz Nominal frequencies
Maximum Input Current 12A @ 100VAC / 12A @ 200VAC
Maximum Power Consumption 1800W
Maximum Heat Output 6143 BTU/hr
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Operating: 5° C to 32° C (41° F to 89.6° F) with HBA (SGX-SAS6-R-INT-Z) installed
Nonoperating: -40° C to 68° C (-40° F to 154°F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing
Nonoperating: up to 93% relative humidity noncondensing
Altitude Single, non-rack system:
Operating: Up to 3048 m (10,000 ft.), maximum operating temperature is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft).
Nonoperating: Up to 12,000 m (39,370 ft.)
Acoustic Noise Emissions LwAd (1B= 10dB) at max ambient: 8.9 B (idle and operating room temperature)
LpAm bystander at max ambient: 75 dBA
Regulations
Meets or exceeds the following requirements:
Safety IEC 60950, UL/CSA60950, EN60950, CB scheme with all country differences
RFI/EMI FCC CFR 47 Part 15 Class A, EN55022 Class A, EN300-386, EN 61000-3-2, EN 61000-3-3
Immunity EN 55024 ,EN 300 386
Certifications Safety: UL/cUL, UL DEMKO, CCC, CE, BSMI, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
Other: Compiles with WEEE (Waste Electrical and Electronic Equipment) Directive (2002/96/EC) and RoHS Directive (2002/95/EC)
Dimensions and Weight
Height 129.85 mm (5.1 in.)
Width 436.5 mm (17.2 in.)
Depth 732 mm (28.8 in.)
Weight Maximum: 38.5 kg (85 lb.)
Rack Mounting
Exalytics In-Memory Machine X2-4 Racks
( Using the Tooless Slide Rail Rackmount Kit PN#371-4791 )
Racks are as follows:
  • Sun Rack 1242
  • Sun Rack 1042

  Copyright � 2012 Sun Microsystems, Inc.  All rights reserved.