Sun Microsystems, Inc.   Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Pillar Axiom 600 Storage System: Hardware Specifications

Disks
50GB SSD, SATA
73GB 15K, FC
200GB SSD, SATA
300GB 15K, FC
500GB 7200K, SATA
600GB 15K, FC
1TB 7200K, SATA
2TB 5400K, SATA
2TB 7200K, SATA
Brick Specifications
  SATA Brick Fibre Channel Brick SSD Brick
Storage Enclosure
  • Interface to Pillar Axiom Slammer or Cascaded Bricks
  • Four FC interfaces per controller
  • Interface to Pillar Axiom Slammer or Cascaded Bricks
  • Four FC interfaces per controller
  • Interface to Pillar Axiom Slammer or Cascaded Bricks
  • Four FC interfaces per controller
  • Features
  • Automatic, transport failover
  • Two RAID 5 (5+P Arrays)
  • Pooled RAID 10
  • Automatic, transport failover
  • One RAID 5 (10+P+S array)
  • Pooled RAID 10
  • Automatic, transport failover
  • Two RAID 5 (5+P Arrays)
  • Pooled RAID 10
  • Redundant and Hot-Swappable Components
  • 13 drives (one hot spare)
  • Two RAID controllers (active/active)
  • Two load-balancing power supplies
  • Enclosure Services Module
  • 12 drives (one hot spare)
  • Two RAID controllers (active/active)
  • Two load-balancing power supplies
  • Enclosure Services Module
  • 13 drives (one hot spare)
  • Two RAID controllers (active/active)
  • Two load-balancing power supplies
  • Enclosure Services Module
  • Pilot and Slammer Interfaces and Components
      Pilot Slammer
    External Interfaces
  • Four 10/100Base-T Ethernet private management interfaces (PMIs)
  • Two 10/100Base-T Ethernet interfaces for management LAN connectivity
  • SAN Slammer:
  • Four 4 Gbps or 8 Gbps FC interfaces
  • iSCSI Slammer:
  • Four 1 GbE interfaces for iSCSI host attachments
  • NAS Slammer:
  • Eight 1 Gb or four 10 GbE interfaces for client network connectivity
  • Optional FC card for tape connectivity
  • iSCSI Combo Slammer:
  • Four 1 GbE interfaces
  • Four 4 Gbps or 8 Gbps FC interfaces
  • Internal Interfaces  
  • Six 10/100Base-T Ethernet interfaces for Pillar Axiom Slammer/Pilot connectivity
  • Twenty-six 2 Gb or 4 Gb FC interfaces for Pillar Axiom Brick/Slammer connectivity
  • Storage Controller Components (Redundant)  
  • Quad-core processors, 48 GB cache
  • Components
  • Two policy controllers per Pillar Axiom Pilot with active/standby failover Intel Celeron processor per storage controller
  • 2 GB or 4 GB RAM per control unit
  • Two power supplies and fans per control unit
  • Two active/active storage controllers per Pillar Axiom Slammer
  • Supported Protocols
  • FTP, HTTP, NDMP, NTP, SNMP, SMTP, SSH
  • SAN:
  • FC protocol, fabric-attached and direct-attached
  • iSCSI protocol, network-attached or direct-attached
  • NAS:
  • NFS V2/V3 over UDP or TCP, CIFS, NDMP
  • Environment
      Pilot Slammer (Series 3) SATA Brick Fibre Channel Brick SSD Brick
    AC Power 100-240 VAC 100-240 VAC 100-240 VAC 100-240 VAC 100-240 VAC
    Frequency 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz
    Max Power Consumption 124 VA HEPS (2 CUs): 552 VA
    PCIe NIM (2 CUs): 533 VA
    PCIX Only NIM (2 CUs): 568 VA
    1TB (7200 RPM): 285 VA
    2TB (5400 RPM): 284 VA
    2TB (7200 RPM): 296 VA
    300GB (15K RPM): 372 VA
    600GB (15K RPM): 351 VA
    50GB: 224 VA
    200GB: 251 VA
    Max Heat Dissipation 375 BTU/hr 1862 BTU/hr 798 BTU/hr 1173 BTU/hr 498 BTU/hr
    AC Plug Type Two IEC C13 320 connection Four IEC 320 C13 connection Two IEC 320 C13 connections Two IEC 320 C13 connections Two IEC 320 C13 connections
     
    Altitude

    Operating: -61 to 3048 m (-200 to 10,000 ft.)
    Non-Operating: -61 to 12,192 m (-200 to 40,000 ft.)

    Ambient Temperature

    Operating: (Up to 7000 ft. elevation) 5° C to 40° C (41° F to 104° F)
    (Up to 10,000 ft. elevation) 5° C to 35° C (41° F to 95° F)
    Non-Operating: -30° C to 70° C (-22° F to 158° F)

    Temperature Gradient

    Operating: 20° C/hr (36° F/hr)
    Non-Operating: 30° C/hr (54° F/hr)

    Non-Condensing Humidity

    Operating: 10% - 85%, noncondensing, 10%/hr gradient, 30° C (86° F) max wet bulb
    Non-Operating: 5% - 95% noncondensing, 10%/hr gradient, 40° C (104° F) max wet bulb

    Vibration

    Operating: 0.1 G RMS, 3-100 (X,Y and Z Axis), 15 Minutes
    Non-Operating: Administered using the Telcordia GR-63 CORE test specifications. Tested with the rack inside a shipping crate.

    Regulations
    Meets or exceeds the following requirements:
    Electromagnetic Emissions and Immunity
    • CISPR 22-A
    • EN55022 Class A radiated and conducted emissions (110V/220V)
    • EN55024 Immunity:
      • EN 61000-3-2
      • EN 61000-3-3
      • EN 61000-4-2 ESD:±4 kV contact, ±8 kV air
      • EN 61000-4-3 Radiated immunity (within the limits that are listed in Pillar technical specifications)
      • EN 61000-4-4 Electrical fast transients/burst:±1 kV AC, ±0.5 kV I/O
      • EN 61000-4-5 Surges ±1 kV differential mode, ±2 kV common mode
      • EN 61000-4-6 Conducted immunity: 3V
      • EN 61000-4-8 PFMF
      • EN 61000-4-11 Supply dips and interruptions: 30% and 100%
    Dimensions and Weights
      Pilot Slammer SATA Brick Fibre Channel Brick SSD Brick
    Height 8.89 cm (3.5 in) 2U 17.78 cm (7 in) 4U 8.89 cm (3.5 in) 2U 8.9 cm (3.5 in) 2U 8.9 cm (3.5 in) 2U
    Width 45 cm (17.7 in) 45 cm (17.7 in) 45 cm (17.7 in) 45 cm (17.7 in) 45 cm (17.7 in)
    Depth 66 cm max (26 in) 66 cm (26 in) 55.88 cm (22 in) 55.5 cm (22 in) 55.5 cm (22 in)
    Weight 18.2 kg (40 lb) 41 kg (91 lb) 26 kg (59 lb) 32 kg (70 lb) 23.13 kg (51 lb)
    Rack
    Height (Inside)

    Pillar Rack: 186.7 cm (73.5 in) 42U
    Non-Pillar Rack (Minimum Requirements): 42U to hold one Pilot, one to four Slammers, or up to 16 Bricks

    Height (Outside)

    Pillar Rack: 199.9 cm (78.7 in)
    Non-Pillar Rack (Minimum Requirements): N/A

    Width (Inside)

    Pillar Rack: 45 cm (17.7 in)
    Non-Pillar Rack (Minimum Requirements): 48.26 cm (19 in) Panel
    45 cm (17.7 in) Rail-to-rail

    Width (Outside)

    Pillar Rack: 60.48 cm (23.8 in) Overall
    45 cm ((17.7 in) Rail-to-rail
    48.26 cm (19 in) Panel
    Non-Pillar Rack (Minimum Requirements): N/A

    Depth (Inside)

    Pillar Rack: 88.9 cm (35 in)
    66-76.2 cm (26-30 in) Rail-to-rail
    Non-Pillar Rack (Minimum Requirements): 88.9 cm (35 in) Overall
    66-76.2 cm (26-30 in) Rail-to-rail

    Depth (Outside)

    Pillar Rack: 100.3 cm (39.5 in)
    Non-Pillar Rack (Minimum Requirements): 109.2 cm (43 in) Maximum

    A Pillar Axiom 42U rack can contain any combination of:
    • One Pilot
    • One to four Slammers, which can be a mix of network attached storage and storage area network Slammers.
    • One to 16 Bricks
    • One to four power distribution units (PDUs).
    Notes:
    • A second cabinet can hold up to 19 Bricks (no Slammers or Pilot).

    • The center of gravity of a populated Pillar 42U rack is toward the front.
      The threshold tilt angle depends on whether the front or back of the rack faces down
      the slope:
      • Front faces downward: 12° maximum slope.
      • Back faces downward: 24° maximum slope.

      Copyright � 2012 Sun Microsystems, Inc.  All rights reserved.