50GB SSD, SATA |
73GB 15K, FC |
200GB SSD, SATA |
300GB 15K, FC |
500GB 7200K, SATA |
600GB 15K, FC |
1TB 7200K, SATA |
2TB 5400K, SATA |
2TB 7200K, SATA |
Brick
Specifications |
|
SATA Brick |
Fibre Channel Brick |
SSD Brick |
Storage Enclosure |
Interface to Pillar Axiom Slammer or Cascaded Bricks
Four FC interfaces per controller
|
Interface to Pillar Axiom Slammer or Cascaded Bricks
Four FC interfaces per controller
|
Interface to Pillar Axiom Slammer or Cascaded Bricks
Four FC interfaces per controller
|
Features |
Automatic, transport failover
Two RAID 5 (5+P Arrays)
Pooled RAID 10
|
Automatic, transport failover
One RAID 5 (10+P+S array)
Pooled RAID 10
|
Automatic, transport failover
Two RAID 5 (5+P Arrays)
Pooled RAID 10
|
Redundant and Hot-Swappable Components |
13 drives (one hot spare)
Two RAID controllers (active/active)
Two load-balancing power supplies
Enclosure Services Module
|
12 drives (one hot spare)
Two RAID controllers (active/active)
Two load-balancing power supplies
Enclosure Services Module
|
13 drives (one hot spare)
Two RAID controllers (active/active)
Two load-balancing power supplies
Enclosure Services Module
|
Pilot
and Slammer Interfaces and Components |
|
Pilot |
Slammer |
External Interfaces |
Four 10/100Base-T Ethernet private management interfaces (PMIs)
Two 10/100Base-T Ethernet interfaces for management LAN connectivity
|
SAN Slammer:
Four 4 Gbps or 8 Gbps FC interfaces
iSCSI Slammer:
Four 1 GbE interfaces for iSCSI host attachments
NAS Slammer:
Eight 1 Gb or four 10 GbE interfaces for client network connectivity
Optional FC card for tape connectivity
iSCSI Combo Slammer:
Four 1 GbE interfaces
Four 4 Gbps or 8 Gbps FC interfaces
|
Internal Interfaces |
|
Six 10/100Base-T Ethernet interfaces for Pillar Axiom Slammer/Pilot
connectivity
Twenty-six 2 Gb or 4 Gb FC interfaces for Pillar Axiom Brick/Slammer
connectivity
|
Storage Controller Components (Redundant) |
|
Quad-core processors, 48 GB cache
|
Components |
Two policy controllers per Pillar Axiom Pilot with active/standby
failover Intel Celeron processor per storage controller
2 GB or 4 GB RAM per control unit
|
Two power supplies and fans per control unit
Two active/active storage controllers per Pillar Axiom Slammer
|
Supported Protocols |
FTP, HTTP, NDMP, NTP, SNMP, SMTP,
SSH
|
SAN:
FC protocol, fabric-attached and direct-attached
iSCSI protocol, network-attached or direct-attached
NAS:
NFS V2/V3 over UDP or TCP, CIFS, NDMP
|
|
|
Pilot |
Slammer (Series 3) |
SATA Brick |
Fibre Channel Brick |
SSD Brick |
AC Power |
100-240 VAC |
100-240 VAC |
100-240 VAC |
100-240 VAC |
100-240 VAC |
Frequency |
50-60 Hz |
50-60 Hz |
50-60 Hz |
50-60 Hz |
50-60 Hz |
Max Power Consumption |
124 VA |
HEPS (2 CUs): 552 VA
PCIe NIM (2 CUs): 533 VA
PCIX Only NIM (2 CUs): 568 VA
|
1TB (7200 RPM): 285 VA
2TB (5400 RPM): 284 VA
2TB (7200 RPM): 296 VA |
300GB (15K RPM): 372 VA
600GB (15K RPM): 351 VA |
50GB: 224 VA
200GB: 251 VA |
Max Heat Dissipation |
375 BTU/hr |
1862 BTU/hr |
798 BTU/hr |
1173 BTU/hr |
498 BTU/hr |
AC Plug Type |
Two IEC C13 320 connection |
Four IEC 320 C13 connection |
Two IEC 320 C13 connections |
Two IEC 320 C13 connections |
Two IEC 320 C13 connections |
|
Altitude |
Operating: -61 to 3048 m (-200 to 10,000 ft.)
Non-Operating: -61 to 12,192 m (-200 to 40,000 ft.)
|
Ambient Temperature |
Operating: (Up to 7000 ft. elevation) 5° C to 40° C (41° F to 104°
F)
(Up to 10,000 ft. elevation) 5° C to 35° C (41° F to 95° F)
Non-Operating: -30° C to 70° C (-22° F to 158°
F)
|
Temperature Gradient |
Operating: 20° C/hr (36° F/hr)
Non-Operating: 30° C/hr (54° F/hr)
|
Non-Condensing Humidity |
Operating: 10% - 85%, noncondensing, 10%/hr gradient, 30° C (86° F) max wet bulb
Non-Operating: 5% - 95% noncondensing, 10%/hr gradient, 40° C (104° F) max wet bulb
|
Vibration |
Operating: 0.1 G RMS, 3-100 (X,Y and Z Axis), 15 Minutes
Non-Operating: Administered using the Telcordia GR-63 CORE
test specifications. Tested with the rack inside a shipping crate.
|
Regulations
Meets or exceeds the following requirements:
|
Electromagnetic Emissions and Immunity |
- CISPR 22-A
- EN55022 Class A radiated and conducted emissions (110V/220V)
- EN55024 Immunity:
- EN 61000-3-2
- EN 61000-3-3
- EN 61000-4-2 ESD:±4 kV contact, ±8 kV air
- EN 61000-4-3 Radiated immunity (within the limits that are listed in Pillar technical specifications)
- EN 61000-4-4 Electrical fast transients/burst:±1 kV AC, ±0.5 kV I/O
- EN 61000-4-5 Surges ±1 kV differential mode, ±2 kV common mode
- EN 61000-4-6 Conducted immunity: 3V
- EN 61000-4-8 PFMF
- EN 61000-4-11 Supply dips and interruptions: 30% and 100%
|
|
|
Pilot |
Slammer |
SATA Brick |
Fibre Channel Brick |
SSD Brick |
Height |
8.89 cm (3.5 in) 2U |
17.78 cm (7 in) 4U |
8.89 cm (3.5 in) 2U |
8.9 cm (3.5 in) 2U |
8.9 cm (3.5 in) 2U |
Width |
45 cm (17.7 in) |
45 cm (17.7 in) |
45 cm (17.7 in) |
45 cm (17.7 in) |
45 cm (17.7 in) |
Depth |
66 cm max (26 in) |
66 cm (26 in) |
55.88 cm (22 in) |
55.5 cm (22 in) |
55.5 cm (22 in) |
Weight |
18.2 kg (40 lb) |
41 kg (91 lb) |
26 kg (59 lb) |
32 kg (70 lb) |
23.13 kg (51 lb) |
|
Height (Inside) |
Pillar Rack: 186.7 cm (73.5 in) 42U
Non-Pillar Rack (Minimum Requirements): 42U to hold one Pilot,
one to four Slammers, or up to 16 Bricks
|
Height (Outside) |
Pillar Rack: 199.9 cm (78.7 in)
Non-Pillar Rack (Minimum Requirements): N/A
|
Width (Inside) |
Pillar Rack: 45 cm (17.7 in)
Non-Pillar Rack (Minimum Requirements): 48.26 cm (19 in)
Panel
45 cm (17.7 in) Rail-to-rail
|
Width (Outside) |
Pillar Rack: 60.48 cm (23.8 in) Overall
45 cm ((17.7 in) Rail-to-rail
48.26 cm (19 in) Panel
Non-Pillar Rack (Minimum Requirements): N/A
|
Depth (Inside) |
Pillar Rack: 88.9 cm (35 in)
66-76.2 cm (26-30 in) Rail-to-rail
Non-Pillar Rack (Minimum Requirements): 88.9 cm (35 in) Overall
66-76.2 cm (26-30 in) Rail-to-rail
|
Depth (Outside) |
Pillar Rack: 100.3 cm (39.5 in)
Non-Pillar Rack (Minimum Requirements): 109.2 cm (43 in)
Maximum
|
A Pillar Axiom 42U rack can contain
any combination of:
- One Pilot
- One to four Slammers, which can be a mix of network attached
storage and storage area network Slammers.
- One to 16 Bricks
- One to four power distribution units (PDUs).
Notes:
- A second cabinet can hold up to 19 Bricks (no Slammers or Pilot).
- The center of gravity of a populated Pillar 42U rack is toward
the front.
The threshold tilt angle depends on whether the front or back
of the rack faces down
the slope:
- Front faces downward: 12° maximum slope.
- Back faces downward: 24° maximum slope.
|