73GB 15000 RPM, FC |
146GB 15000 RPM, FC |
300GB 15000 RPM, FC |
450GB 15000 RPM, FC |
160GB 7200 RPM, SATA |
250GB 7200 RPM, SATA |
400GB 7200 RPM, SATA |
500GB 7200 RPM, SATA |
750GB 7200 RPM, SATA |
1TB 7200 RPM, SATA |
2TB 5400 RPM, SATA |
Brick
Specifications |
|
SATA Brick |
Fibre Channel Brick |
Storage Enclosure |
Interface to Slammer or Cascaded Bricks
Four FC interfaces per controller, 200 Mb/s (2Gb) with port bypass
Disk Drive Interface
Dual-ported Serial ATA
Performance
350 Mb/s, in excess of 1000 random IOPS
RAID Controller Specifications
400MHz XScale ARM
128MB ECC memory per controller
4MB flash memory
Features
Two RAID controllers per Brick (active/active)
Automatic transparent failover
Two RAID 5 5+P arrays
|
Interface to Slammer or Cascaded Bricks
Four FC interfaces per controller, 200 Mb/s (2Gb) with port bypass
Disk Drive Interface
Fibre Channel
Performance
400 Mb/s, 2500 random IOPS
RAID Controller Specifications
600 Mhz XScale ARM
256 MB ECC memory per controller
4MB flash memory
RAID Controller Features
Two RAID controllers per Brick
Automatic transparent failover
One RAID 5 10+P array
Distributed RAID 10
|
Features and Specifications |
13-Drive enclosure
Redundant and Hot-Swappable Components
Two RAID controlllers
13 disk drives (one hot spare)
Two load-balancing power supplies
Enclosure Services Module
|
12-Drive enclosure
Redundant and Hot-Swappable Components
Two RAID controlllers (if specified)
12 disk drives (one hot spare)
Two load-balancing power supplies
Enclosure Services Module
|
Pilot
and Slammer Interfaces and Components |
|
Pilot |
Slammer |
External Interfaces |
Four 10/100Base-T Ethernet private management interfaces (PMIs)
Two 10/100Base-T Ethernet interfaces for management LAN connectivity
|
Four 1Gb Ethernet interfaces for host-to-LAN connectivity on
NAS Slammers or SAN connectivity on iSCSI Slammers
Four 4Gb Fibre Channel ports for host-to-SAN connectivity on
SAN Slammers
|
Internal Interfaces |
|
Six 10/100Base-T Ethernet interfaces for Slammer/Pilot connectivity
Twelve 2Gb Fibre Channel interfaces for Brick/Slammer connectivity
|
Control Unit Components (Two per Slammer) |
Two control units per Pilot with active/passive failover
Intel Celeron 2.5GHz processor per control unit
2Gb of RAM per control unit
|
One Intel Xeon 2.4GHz processor
Up to 3Gb of RAM
Optional Fibre Channel or Ultra SCSI card for tape attachment
|
Redundant and Hot-Swappable Components |
|
Two load-balancing power supplies and fans per Slammer
Two active/active control units per Slammer
Fibre Channel interface modules
Motherboards
|
Supported Protocols |
FTP, HTTP, NDMP, NTP, SNMP, SMTP, SSH
|
Network Protocol Support:
NFS V2/V3 over UDP or TCP, CIFS, NDMP
SAN Protocol Support:
Fibre Channel Protocol (FCP) for SCSI; fabric-attached and direct
attached iSCSI
|
|
|
Pilot |
Slammer |
SATA Brick |
Fibre Channel Brick |
AC Power |
90-264 VAC |
90-264 VAC |
90-264 VAC |
90-264 VAC |
Frequency |
50-60 Hz |
50-60 Hz |
50-60 Hz |
50-60 Hz |
Max Power Consumption |
280 VA |
685 VA |
255 VA |
400 VA |
Max Heat Dissipation |
989 BTU/hr |
2,336 BTU/hr |
870 BTU/hr |
1,370 BTU/hr |
AC Plug Type |
IEC 320 C13 connection |
IEC 320 C13 connection |
Two IEC 320 C13 connections |
Two IEC 320 C13 connections |
Temperature |
Operating: 10 to 40° C
Non-Operating: -40 to 70 ° C |
Operating: 10 to 40° C
Non-Operating: -40 to 70 ° C |
Operating: 10 to 40° C
Non-Operating: -40 to 70 ° C |
Operating: 10 to 40° C
Non-Operating: -40 to 70 ° C |
Temperature Gradient |
Operating: 10° C/hr
Non-Operating: 30° C/hr |
Operating: 10° C/hr
Non-Operating: 30° C/hr |
Operating: 10° C/hr
Non-Operating: 30° C/hr |
Operating: 20° C/hr
Non-Operating: 30° C/hr |
Relative Humidity |
Operating: 10 - 85%, non-condensing
Non-Operating: 5 - 95%, non-condensing |
Operating: 10 - 85%, non-condensing
Non-Operating: 5 - 95%, non-condensing |
Operating: 10 - 85%, non-condensing
Non-Operating: 5 - 95%, non-condensing |
Operating: 10 - 85%, non-condensing
Non-Operating: 5 - 95%, non-condensing |
Humidity Gradient |
Operating: 10%/hr, non-condensing
Non-Operating: 10%/hr, non-condensing |
Operating: 10%/hr, non-condensing
Non-Operating: 10%/hr, non-condensing |
Operating: 10%/hr, non-condensing
Non-Operating: 10%/hr, non-condensing |
Operating: 10%/hr, non-condensing
Non-Operating: 10%/hr, non-condensing |
Regulations
Meets or exceeds the following requirements:
|
Electromagnetic Emissions and Immunity |
- CISPR 22-A
- EN55022 Class A radiated and conducted emissions (110V/220V)
- EN55024 Immunity:
- EN 61000-3-2
- EN 61000-3-3
- EN 61000-4-2 ESD:±4 kV contact, ±8 kV air touch
- EN 61000-4-3 Radiated immunity (within the limits that are listed in Pillar technical specifications)
- EN 61000-4-4 Electrical fast transients/burst:±1 kV AC, ±0.5 kV I/O
- EN 61000-4-5 Surges ±1 kV differential mode, ±2 kV common mode
- EN 61000-4-6 Conducted immunity: 3V
- EN 61000-4-8
- EN 61000-4-11 Supply dips and interruptions: 30% and 100%
- VCCI (Japan)
|
|
|
Pilot |
Slammer |
SATA Brick |
Fibre Channel Brick |
Height |
8.89 cm (3.5 in) 2U |
17.78 cm (7 in) 4U |
8.89 cm (3.5 in) 2U |
8.9 cm (3.5 in) 2U |
Width |
45 cm (17.7 in) |
45 cm (17.7 in) |
45 cm (17.7 in) |
45 cm (17.7 in) |
Depth |
66 cm max (26 in) |
66 cm (26 in) |
55.5 cm (22 in) |
55.5 cm (22 in) |
Weight |
18.2 kg (40 lb) |
41 kg (91 lb) |
26 kg (59 lb) |
32 kg (70 lb) |
|
Height (Inside) |
Pillar Rack: 186.7 cm (73.5 in) 42U
Non-Pillar Rack (Minimum Requirements): 18U to hold one Pilot,
one Slammer, or up to four Bricks
|
Height (Outside) |
Pillar Rack: 199.9 cm (78.7 in)
Non-Pillar Rack (Minimum Requirements): N/A
|
Width (Inside) |
Pillar Rack: 45 cm (17.7 in)
Non-Pillar Rack (Minimum Requirements): 48.26 cm (19 in)
Panel
45 cm (17.7 in) Rail-to-rail
|
Width (Outside) |
Pillar Rack: 60.48 cm (23.8 in) Overall
45 cm ((17.7 in) Rail-to-rail
48.26 cm (19 in) Panel
Non-Pillar Rack (Minimum Requirements): N/A
|
Depth (Inside) |
Pillar Rack: 88.9 cm (35 in)
66-76.2 cm (26-30 in) Rail-to-rail
Non-Pillar Rack (Minimum Requirements): 88.9 cm (35 in) Overall
66-76.2 cm (26-30 in) Rail-to-rail
|
Depth (Outside) |
Pillar Rack: 100.3 cm (39.5 in)
Non-Pillar Rack (Minimum Requirements): 109.2 cm (43 in)
Maximum
|
Front Door |
Pillar Rack:
- Vented
- Light-tint Plexiglas
- 3.81 cm (1.5 in) deep
- Lockable
- Open left/right
- 2.54 cm (1in) clearance between front vertical channel and inside of frame
Non-Pillar Rack (Minimum Requirements):
- Vented
- 2.54 cm (1in) deep minimum
- 2.54 cm (1in) clearance between front vertical channel and inside of frame
|
Rear Door |
Pillar Rack:
- Vented
- Lockable
- Open left/right
Non-Pillar Rack (Minimum Requirements):
|
Sides |
Pillar Rack:
- Solid
- Removable
- Lockable
- 2.54 cm (1in) between side and frame
Non-Pillar Rack (Minimum Requirements):
|
A Pillar rack contains:
- One Pilot
- One network attached storage or storage area network Slammer.
- One to four Bricks
- One to four power distribution units (PDUs).
|