| Processor |
| Number |
1 to 2 Quad-Core |
| Architecture |
Type: Intel Xeon Quad-Core Processor |
| CPUs |
Intel 2.40GHz Quad-Core Xeon E5620 (12MB L3, 80W)
|
| Main Memory |
| Capacities |
Total DIMM slots: 18
DIMM type: DDR3 1333MHz Registered DIMMs
DIMM size: 4-GB 1333MHz
Maximum capacity: 72GB (when fully populated with 4-GB DIMMs)
|
| Standard
Integrated Interfaces |
| Network |
Four 10/100/1000 Base-T Ethernet Ports
|
| Network Management |
One dedicated 10/100Base-T Ethernet port |
| Serial Management |
One dedicated TIA/EIA-232-F asynchronous RJ45 port |
| USB |
Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port (for a USB thumb drive) |
| PCI Expansion Slots |
Three low profile PCI Express 2.0 slots
(1 x16 electrical/mechanical, 2 x8 electrical/mechanical) |
| Internal Mass Storage |
| Disks |
SAS: Up to eight 2.5" SATA Disks with add-on SAS Host Bus Adapter
SATA-2: Up to six 2.5" Solid State Drives
Drive Type
|
Density
|
Speed
|
Form Factor
|
SAS
|
300GB, 600GB
|
15,000 RPM
|
3.5"
|
SAS
|
1TB, 2TB
|
7,200 RPM
|
3.5"
|
SATA
|
500GB
|
7,200 RPM
|
2.5"
|
SSD (Solid State Drives) SAS
|
18GB
|
NA
|
3.5"
|
SSD (Solid State Drives) SATA
|
18GB
|
NA
|
2.5"
|
|
| Power Supplies |
Dual redundant, hot swappable power supplies
(Power supply rating output = 760W)
(UL Maximum AC input = 760W x 1.33 efficiency = 1010W)
(9.0 Amps RMS at 100 VAC)
|
| Environment |
| AC power |
100-120 / 200-240 VAC (50-60 Hz) |
| Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to
158° F)
|
| Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing,
27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing,
38° C (100.4° F) max wet bulb |
| Altitude |
Single, non-rack system:
Operating: up to 3000 m (9,843 ft.), maximum ambient
temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.) |
Regulations
Meets or exceeds the following
requirements: |
| RoHS Compliance Level |
RoHS:YL |
| Safety |
UL 60950-1 2nd Ed, EN60950-1:2006 2nd Ed, CB Scheme with all country
differences |
| RFI/EMI |
FCC CFR 47 Part 15 Subpart B Class A, EN55022:2006+A1:2007 Class A, EN 61000-3-2,
EN61000-3-3, EN 300-386 |
| Immunity |
EN55024, EN300-386 |
| Certifications |
Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
|
| Dimensions and Weight |
| Height |
43.43 mm (1.71 in.) |
| Width |
425.5 mm (16.75 in.) |
| Depth |
685.8 mm (27.0 in.) |
| Weight |
16.36 kg (36 lb.) maximum assuming PCI-Express card weighs 0.12 kg
(0.25 lb) each, and without the rack mounting slide rail kit installed.
|
| Rack Mounting |
| Sun ZFS Storage 7320 Racks |
Racks are as follows:
- Sun Rack II 1042
- Sun Rack II 1242
|