Sun ZFS Storage 7320: Hardware Specifications

Processor
Number 1 to 2 Quad-Core
Architecture Type: Intel Xeon Quad-Core Processor
CPUs Intel 2.40GHz Quad-Core Xeon E5620 (12MB L3, 80W)
Main Memory
Capacities Total DIMM slots: 18
DIMM type: DDR3 1333MHz Registered DIMMs
DIMM size: 4-GB 1333MHz
Maximum capacity: 72GB (when fully populated with 4-GB DIMMs)
Standard Integrated Interfaces
Network Four 10/100/1000 Base-T Ethernet Ports
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated TIA/EIA-232-F asynchronous RJ45 port
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port (for a USB thumb drive)
PCI Expansion Slots Three low profile PCI Express 2.0 slots (1 x16 electrical/mechanical, 2 x8 electrical/mechanical)
Internal Mass Storage
Disks SAS: Up to eight 2.5" SATA Disks with add-on SAS Host Bus Adapter
SATA-2: Up to six 2.5" Solid State Drives
Drive Type
Density
Speed
Form Factor
SAS
300GB, 600GB
15,000 RPM
3.5"
SAS
1TB, 2TB
7,200 RPM
3.5"
SATA
500GB
7,200 RPM
2.5"
SSD (Solid State Drives) SAS
18GB
NA
3.5"
SSD (Solid State Drives) SATA
18GB
NA
2.5"
Power Supplies
Dual redundant, hot swappable power supplies
(Power supply rating output = 760W)
(UL Maximum AC input = 760W x 1.33 efficiency = 1010W)
(9.0 Amps RMS at 100 VAC)
Environment
AC power 100-120 / 200-240 VAC (50-60 Hz)
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
Altitude Single, non-rack system:
Operating: up to 3000 m (9,843 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.)
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety UL 60950-1 2nd Ed, EN60950-1:2006 2nd Ed, CB Scheme with all country differences
RFI/EMI FCC CFR 47 Part 15 Subpart B Class A, EN55022:2006+A1:2007 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386
Immunity EN55024, EN300-386
Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
Dimensions and Weight
Height 43.43 mm (1.71 in.)
Width 425.5 mm (16.75 in.)
Depth 685.8 mm (27.0 in.)
Weight 16.36 kg (36 lb.) maximum assuming PCI-Express card weighs 0.12 kg
(0.25 lb) each, and without the rack mounting slide rail kit installed.
Rack Mounting
Sun ZFS Storage 7320 Racks Racks are as follows:
  • Sun Rack II 1042
  • Sun Rack II 1242

  Copyright � 2012 Sun Microsystems, Inc.  All rights reserved.