Sun Storage 2530-M2 Array |
Up to twelve disk drives as follows:
- 300GB 15000 RPM, 6 Gb/sec SAS-2
- 600GB 15000 RPM, 6 Gb/sec SAS-2
|
|
300GB Disk drives |
12 x 300GB = 3.6TB |
600GB Disk drives |
12 x 600GB = 7.2TB |
Drive Specifications |
Form factor: 3.5
in., low-profile
Interface: Dual-ported SAS-2 |
Note 1: Dynamic capacity expansion
of 5 to 48 drives - 600 GB to 28.8 TB
Note 2: Up to three expansion trays are supported.
Note 3: Drive depopulation scales from
5 to 12 disk drives per tray.
Note 4: RAID Levels: 0, 1, 10, 3, 5, 6, (P+Q)
Note 5: Cache Battery Backup: Up to 72 hours (depending on cache size) |
Interfaces |
Host interfaces/link speeds |
4 × 6Gbps auto-negotiating SAS-2 host ports, up
to 2GB cache per controller |
Other interfaces |
Up to two 10/100 Base-T Ethernet |
Serial |
Up to two nine-pin RS-232 ports per dual controller
tray |
|
Heat Output
|
1366 BTU/hr |
AC Power |
100-240V ~, 7.0-2.9A,
50/60Hz |
DC Power |
-42 to -60Vdc, 21.7-15.3A |
Temperature |
Operating: 10°
C to 40° C (50° F to 104° F)
Maximum rate of change: 15° C (59° F) per hour
Storage: -10° C to 50° C (14° F to 122° F).
Maximum rate of change: 10° C (50° F) per hour
Transit: -40° C to 140° C (-40° F to 140°
F)
Maximum rate of change: 20° C (68° F) per hour |
Relative Humidity |
Operating: 20%
to 80% relative humidity, noncondensing. 10° C (50° F) per
hour gradient (max)
Storage: 10% to 90% relative humidity. 15° C (59°
F) per hour gradient (max)
Transit: 5% to 90% relative humidity. 20° C (68°
F) per hour gradient (max)
Dewpoint: 26° C (79° F) max |
Altitude |
Operating: 30.5
m (100 ft) below sea level to 3000 m (9840 ft) above sea level
Storage: 30.5 m (100 ft) below sea level to 3000 m (9840 ft)
above sea level
Tranist: 30.5 m (100 ft) below sea level to 12000 m (40000
ft) above sea level |
Acoustic |
Sound Power: 6.2
bels (max - standy operation)
Sound Pressure: 6.2 bels (max - standy operation)
|
Shock |
Operating: 10-g
peak acceleration, 5 ms duration, 1/2 sine pulse
Non-Operating: 20-g peak acceleration, 8ms duration, trapezoidal
pulse
|
Vibration |
Operating: 5-500-5
Hz, sinusoidal
Non-Operating: 5-500-5 Hz, sinusoidal, 1 octave per minute,
flat profile .50 G
|
|
Height |
86.4 mm (3.4 in) |
Width |
482.6 mm (19 in) |
Depth |
552.5 mm (21.75 in) |
Weight (maximum) |
27 kg (59.52 lb) |
|
Note: Meets or exceeds the following
requirements. |
Safety |
UL, C-UL, CE, BSMI (DoC),
GOST |
Emmissions/Immunity |
FCC Class A, ICES-003
Class A, VCCI Class A, EN55022 Class A/EN55024 (CE), CNS13438 (BSMI
DoC), AS/NZS CISPR22 (C-Tick), KN22/KN24 (KC) |
Environmental |
RoHS, WEEE |
NEBs Level 3 |
GR-63 CORE requirements,
GR-1089 CORE requirements |
|
Rack mountable in 19 inch-wide rack
|
Clearance
and Service Access
|
Front |
76 cm (30 in) |
Rear |
61 cm (24 in) |
Airflow for cooling is from front
to rear. |