Sun Microsystems, Inc.   Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

 

Sun Blade X6440 Server Module LEDs

 

External Status Indicator LEDs

External Status Indicator LEDs

LED Name / Color Status Description
Locate Button and
Locate LED / White
On or Blinking
This LED helps you to identify which system in the rack you are working on in a rack full of servers.
  • Push and release this button to make the Locate LED blink for 30 minutes.
  • Hold down the button for 5 seconds to initiate a "push-to-test" mode that illuminates all other LEDs both inside and outside the chassis for 15 seconds.

Off
Normal operating state. The Locate LED can be turned off by pushing the Locate button.
Ready-to-Remove LED / Blue
On
The server module is ready to be removed from the chassis. This LED is switched on by the service processor when the server module main power is off.
Off
Normal operation.
Service Action Required LED / Amber
Off
Normal operation.
Slow Blinking
A new (unacknowledged) event requiring a service action has been detected.
On
The event has been acknowledged, but the problem still requires attention.
Power/OK LED / Green
Off
Server main power and standby power are off.
Standby Blinking
Standby power is on, but main power is off.
Slow Blinking
POST or diagnostics are running.
On
Server is in main power mode with power supplied to all components.
Button Name Description
Power Button
Turns the host system on and off. Use a stylus or other small tipped object to completely press this button.
NMI Button
For Service only.

 

  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.