Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|||
Sun Blade X6440 Server Module LEDsExternal Status Indicator LEDs | |||||||||||||||||||||||||||||||||||
| LED Name / Color | Status | Description |
|---|---|---|
| Locate Button and Locate LED / White |
On or Blinking
|
This LED helps you to identify which system in the rack you
are working on in a rack full of servers.
|
|
Off
|
Normal operating state. The Locate LED can be turned off by pushing the Locate button. | |
| Ready-to-Remove LED / Blue |
On
|
The server module is ready to be removed from the chassis. This LED is switched on by the service processor when the server module main power is off. |
|
Off
|
Normal operation. | |
| Service Action Required LED / Amber |
Off
|
Normal operation. |
|
Slow Blinking
|
A new (unacknowledged) event requiring a service action has been detected. | |
|
On
|
The event has been acknowledged, but the problem still requires attention. | |
| Power/OK LED / Green |
Off
|
Server main power and standby power are off. |
|
Standby Blinking
|
Standby power is on, but main power is off. | |
|
Slow Blinking
|
POST or diagnostics are running. | |
|
On
|
Server is in main power mode with power supplied to all components. |
| Button Name | Description |
|---|---|
| Power Button |
Turns the host system on and off. Use a stylus or other small tipped object to completely press this button.
|
| NMI Button |
For Service only.
|
|
Copyright © 2012 Sun Microsystems, Inc. All rights reserved. Feedback | |||