Sun Microsystems, Inc.   Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



cPCI I/O Board

Sun Fire 3800

Option 4040

501-5531 540-4591
cPCI Assembly FRU Assembly

6-Slot cPCI Riser 501-5532

PCI Device Mapping

PHYSICAL SLOT # DEVICE PATH SCHIZO LEAF
5 IB9 /[email protected],0/[email protected],700000/<device>@2 1 B
IB8 /[email protected],0/[email protected],700000/<device>@2
IB7 /[email protected],0/[email protected],700000/<device>@2
IB6 /[email protected],0/[email protected],700000/<device>@2
4 IB9 /[email protected],0/[email protected],700000/<device>@1
IB8 /[email protected],0/[email protected],700000/<device>@1
IB7 /[email protected],0/[email protected],700000/<device>@1
IB6 /[email protected],0/[email protected],700000/<device>@1
3 IB9 /[email protected],0/[email protected],700000/<device>@2 0
IB8 /[email protected],0/[email protected],700000/<device>@2
IB7 /[email protected],0/[email protected],700000/<device>@2
IB6 /[email protected],0/[email protected],700000/<device>@2
2 IB9 /[email protected],0/[email protected],700000/<device>@1
IB8 /[email protected],0/[email protected],700000/<device>@1
IB7 /[email protected],0/[email protected],700000/<device>@1
IB6 /[email protected],0/[email protected],700000/<device>@1
1 IB9 /[email protected],0/[email protected],600000/<device>@1 1 A
IB8 /[email protected],0/[email protected],600000/<device>@1
IB7 /[email protected],0/[email protected],600000/<device>@1
IB6 /[email protected],0/[email protected],600000/<device>@1
0 IB9 /[email protected],0/[email protected],600000/<device>@1 0
IB8 /[email protected],0/[email protected],600000/<device>@1
IB7 /[email protected],0/[email protected],600000/<device>@1
IB6 /[email protected],0/[email protected],600000/<device>@1

Sun Fire 3800-6800 Codename: Serengeti

Notes

  1. The minimum operating system is Solaris 8 4/01.
  2. The 6-Slot cPCI I/O Board is not hot pluggable.
  3. I/O Board slots are labeled IB6 and IB8.
  4. The I/O Board includes an I/O Board, cPCI Riser, and Cardcage.
  5. Chassis labels include the abbreviated name and number.
  6. The right to left system installation sequence is IB8 then IB6.
  7. Install Filler Board 540-4446 in all empty cPCI board slots.
  8. Install Filler Panel 330-3155 when servicing a cPCI I/O board slot.
  9. How To article 1005873.1 provides a "ftp-only" shortcut for updating the flashprom firmware.
  10. Refer to the Install.info file of any Firmware patch for information on firmware verification and compatibility.

References

  1. Sun Fire 3800 Server Documentation.

  Copyright 2012 Sun Microsystems, Inc.  All rights reserved.