Sun Microsystems, Inc.   Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Firmware

Netra 6000
Netra CT 900
Sun Blade 6000
Sun Blade 6048
Sun Blade Storage Module M2

SPARCstorage Array
StorEdge A5000/A5100/A5200
EXX00 I/O Board
Sun Fire 3800/48x0/6800
Sun Fire 3800/48x0/6800/E4900/E6900
Netra 1280/1290 / Sun Fire V1280/E2900
StorEdge T3
StorEdge T3+
StorEdge 3120 JBOD I/O Module
StorEdge 3310 SCSI RAID
StorEdge 3320 SCSI Array
StorEdge 3510 RAID
StorEdge 3511 SATA RAID
StorEdge 6020/6120 Array

Multi-Fabric Network Express Module
Virtualized Multi-Fabric Network Express Module
Virtualized Multi-Fabric M2 Network Express Module

1Gb/Sec SBus Dual Fibre Channel Host Adapter
1Gb/Sec PCI Single Fibre Channel Network Adapter
1Gb/Sec PCI Dual Fibre Channel Network Adapter+
1Gb/Sec cPCI Dual Fibre Channel Network Adapter
2Gb/Sec PCI Single Fibre Channel Host Adapter
2Gb/Sec Single Fibre Channel Network Adapter (JNI)
2Gb/Sec PCI Dual Fibre Channel Network Adapter
2Gb/Sec Dual Fibre Channel Network Adapter (JNI)
4Gigabit/Sec Single PCI-X Fibre Channel Network Adapter
4Gigabit/Sec Dual PCI-X Fibre Channel Network Adapter
4Gigabit/Sec Single PCIe Fibre Channel Network Adapter
4Gigabit/Sec Dual PCIe Fibre Channel Network Adapter
4Gigabit/Sec Dual PCIe Fibre Channel Network Adapter
8Gigabit/Sec Single PCIe Fibre Channel Network Adapter
8Gigabit/Sec Dual PCIe Fibre Channel Network Adapter

Dual Ultra-320 SCSI Host Bus Adapter
8-Port SAS/SATA Host Bus Adapter

Brocade Silkworm
PCI Express Quad Gigabit Ethernet UTP
RAID Expansion Module
Flash Accelerator F20


Sun Blade 6000 and Netra 6000

Constellation 10 Chassis Management Module 371-1447
with Service Processor 501-7516 or 501-7985

Sun Blade 6000 Chassis SW 4.X Patch Readmes and Downloads
Sun Blade 6000 Chassis SW 1.X and 3.X Patch Readmes and Downloads
Sun Blade 6000 10GbE Switched NEM Patch Readmes and Downloads
Sun Blade 6000 10GbE VMF NEM Patch Readmes and Downloads
Sun Blade 6000 10GbE VMF NEM M2 Patch Readmes and Downloads
Sun Netra 6000 Chassis Patch Readmes and Downloads

525-2390-05 SP Flash R16671 (WO_35394)
Supplement 1.0 SP Flash 1.1.6 (not ECO released)
525-2390-06 SP Flash 1.1.8 (System Supplement 1.0.1) 1 (WO_37712)
525-2390-07 SP Flash 2.0.3.1-R23241 (System Supplement 1.1) (WO_38122)
525-2390-08 SP Flash 2.0.3.1-R26140 (WO_38445)
525-2390-09 SP Flash 2.0.3.2-R30353 (System Supplement 1.2) (WO_38032)
Download 2.0 SP Flash 2.0.3.3-R33795 (not ECO released) (Supplement 2.0)
525-2390-10 ILOM 2.0.3.10-R36968 (System Supplement 2.1) (WO_40208)
Download 3.0 ILOM 3.0.3.32-R43452 (not ECO released) (SW 3.0) 2
525-2390-11 ILOM 3.0.6.11-R47352 (SW 3.0) (WO_40787)
525-2390-12 ILOM 3.0.6.11b R48988 (Software 3.1.2) (WO_42005)
None ILOM 3.0.6.11c R51868 (Software 3.1.3) (WO_42667) 3
525-2390-13 ILOM 3.0.10.15 R55620 (Software 3.2) (WO_42667)
10271353 Software Download 3.2.1
ILOM 3.0.10.15a (not ECO released) (Software 3.2.1) 4
10271345 Software Download 3.2.2
ILOM 3.0.10.15b (not ECO released) (Software 3.2.2) 5
10411087 Software Download 3.3
ILOM 3.0.12.11 (not ECO released)
11879422 Software Download 3.3.2
ILOM 3.0.12.11.a
13485957 Software Download 3.3.4 (AC)
ILOM 3.0.12.11.c
13485960 Software Download 3.3.4 (DC)
ILOM 3.0.12.11.c
13922665 Software Download 3.3.5
ILOM 3.0.12.11.d
1 525-2390-06 was the first version released on 501-7985-01 in October 2007.
2 ECO WO_41017 was cancelled in August 2009.
3 First firmware release to support Netra 6000.
4 Includes the Sun Blade Zone Manager for SAS2 Chassis Environment.
5 Adds support for SGX-SAS6-REM-Z on the Sun Blade X6270 M2 server module.


Sun Blade 6000 and Netra 6000
Constellation 10 Chassis Management Module 501-7379

Sun Blade 6000 Chassis SW 4.X Patch Readmes and Downloads
Sun Blade 6000 Chassis SW 1.X and 3.X Patch Readmes and Downloads
Sun Blade 6000 10GbE Switched NEM Patch Readmes and Downloads
Sun Blade 6000 10GbE VMF NEM Patch Readmes and Downloads
Sun Blade 6000 10GbE VMF NEM M2 Patch Readmes and Downloads
Sun Netra 6000 Chassis Patch Readmes and Downloads

525-2167-04 P87LPC764 I2C Bus Master (4-Eyes) 1 (WO_33050)
525-2167-05 P87LPC764 I2C Bus Master (4-Eyes) 1 2 3 (WO_33050)
1 The P87LPC764 at U19 is not reprogramable.
2 525-2167-05 is on CMM Assembly 371-1447-06. (Refer to Solution 259708, FCO A0304-1)
3 Reduces the risk of ILOM firmware failure due to shared multimaster I2C bus timeouts.


Sun Blade 6000 and Netra 6000
Constellation 10 Chassis Management Module 541-4340
with Service Processor 511-1531

Sun Blade 6000 Chassis SW 4.X Patch Readmes and Downloads
Sun Blade 6000 Chassis SW 1.X and 3.X Patch Readmes and Downloads
Sun Blade 6000 10GbE Switched NEM Patch Readmes and Downloads
Sun Blade 6000 10GbE VMF NEM Patch Readmes and Downloads
Sun Blade 6000 10GbE VMF NEM M2 Patch Readmes and Downloads
Sun Netra 6000 Chassis Patch Readmes and Downloads

525-2962-02 ILOM 3.0.12.1 (SW 4.0) (WO_42714)
525-2962-03 ILOM 3.0.12.10 R58079 (SW 4.0) (WO_43626)
525-2962-04 ILOM 3.0.12.10 R59451 (SW 4.0) (E0000194)
10420264 Software Download 4.0
version unknown 1
11897524 Software Download 4.1
ILOM 3.0.16.14 1
13543725 Software Download 4.1.1 (7100417)
ILOM 3.0.16.14.a
13543748 Software Download 4.1.1 (7100418)
ILOM 3.0.16.14.a
14019601 Software Download 4.2.1 (Sun Blade 6000)
ILOM 3.1.1.10a 1
14692752 Software Download 4.2.1 (7100417) (Netra 6000)
ILOM 3.1.1.10a
14692758 Software Download 4.2.1 (7100418) (Netra 6000)
ILOM 3.1.1.10a
1 A90-D chassis version only.



Netra CT 900

Blade Server Chassis
Shelf Management Controller 370-7762 & 371-3037

Patch Readmes and Downloads

141788-02 Chassis Firmware R3U2P1 (not ECO released)
141788-03 Chassis Firmware R3U2P2 (not ECO released)
141788-06 Chassis Firmware R3U2P3 (not ECO released)
141788-08 Chassis Firmware R3U2P4 (not ECO released)
141788-10 Chassis Firmware R3U2P5 (not ECO released)
141788-11 Chassis Firmware R3U2P6 (not ECO released)
144609-01 Chassis Firmware R3U3P1 (not ECO released)
144609-04 Chassis Firmware R3U3P2 (not ECO released)
144609-06 Chassis Firmware R3U3P3 (not ECO released)
144609-07 Chassis Firmware R3U3P4
144609-08 Chassis Firmware R3U3P5



Sun Blade 6048

Constellation 48 Chassis Management Module 540-7545
with Service Processor 501-7893

Patch Readmes and Downloads

525-2509-07 ILOM R22824 (WO_37453)
525-2509-08 ILOM 2.0.3.1 R24146 (Chassis Download 1.0) (WO_38082)
525-2509-09 ILOM 2.0.3.1 R26138 (Chassis Download 1.0a) (WO_38531)
525-2509-10 ILOM 2.0.3.2 R30353 (Chassis Download 1.1) (WO_39053)
525-2509-11 ILOM 2.0.3.3 R33795 (Chassis Download 2.0) 1 (WO_39571)
525-2509-12 ILOM 2.0.3.10 R36968 (Chassis Download 2.1) 2 (WO_40143)
Unknown ILOM 3.0.3.32 (not ECO released) (Software 3.0)
525-2509-13 ILOM 3.0.6.11 R47352 (Software 3.1) (WO_41067)
525-2509-14 ILOM 3.0.6.11b R48988 (Software 3.1.2) (WO_42005)
525-2509-15 ILOM 3.0.6.11c R51868 (Software 3.1.3) (WO_42667)
10271568 Software Download 3.2.1
ILOM 3.0.10.15a (not ECO released)
10271562 Software Download 3.2.2
ILOM 3.0.10.15b (not ECO released)
10411089 Software Download 3.3
ILOM 3.0.12.11 (not ECO released)
12404576 Software Download 3.3.2
ILOM 3.0.12.11.a (not ECO released)
12908939 Software Download 3.3.3
ILOM 3.0.12.11.b
13946479 Software Download 3.3.5
ILOM 3.0.12.11.d
1 Adds support for the InfiniBand Switched Network Express Module X5196A-Z.
2 Adds support for Sun Blade T6340 and partial support for NEM X4238 (Hydra) .



Sun Blade Storage Module M2

Vela2 Disk Blade Board 511-1399 / 540-7961

Patch Readmes and Downloads

525-2880-04 LSI Expander Firmware 5.03.04.00 (WO_42736)
525-2880-05 LSI Expander Firmware 5.03.05.00 (WO_43315)
525-2880-06 LSI Expander Firmware 5.03.06.00 (SW 1.0.1) (WO_43616)



SPARCstorage Array

SSA Model 100 Array Controller Firmware

PART # U1202
Surface Mount
U1203
Surface Mount
U1204
Surface Mount
U1210
PLCC
Rev.
Not used 525-1367-01 525-1368-01 525-1365-01 525-1366-01
501-2080-05 525-1367-02 525-1368-02 525-1365-02 525-1366-02
501-2080-06 525-1367-03 525-1368-03 525-1365-03 525-1366-03
501-2080-07 525-1367-04 525-1368-04 525-1365-04 525-1366-03 1.3
501-2080-08 525-1367-04 525-1368-04 525-1365-04 525-1366-04 1.3
Not used 525-1367-05 525-1368-05 525-1365-05 525-1366-05 1.9
Not released Not released Not released Not released 525-1366-xx 1.10
Not released Not released Not released Not released 525-1366-xx 1.11
Not released Not released Not released Not released 525-1366-xx 1.12
501-2080-09 525-1367-06 525-1368-06 525-1365-06 525-1366-06 2.0
501-2080-10 525-1367-06 525-1368-06 525-1365-06 525-1366-07 2.0
Not released Not released Not released Not released 525-1366-xx 2.1
Not released Not released Not released Not released 525-1366-xx 2.3
501-2080-11 525-1367-07 525-1368-07 525-1365-07 525-1366-07 2.4
Not released Not released Not released Not released 525-1366-xx 3.3
Not released Not released Not released Not released 525-1366-xx 3.4 1
501-2080-12 525-1437-03 525-1438-03 525-1435-03 525-1366-07 3.4
Not released Not released Not released Not released 525-1366-xx 3.5 2
501-2080-13 525-1437-04 525-1438-04 525-1435-04 525-1366-07 3.6 3
Not released Not released Not released Not released 525-1366-xx 3.9 4
501-2080-14 525-1437-05 525-1438-05 525-1435-05 525-1366-07 3.11
501-2080-15 525-1437-07 525-1438-07 525-1435-07 525-1366-07 3.12
  1. Revision 3.4 was approved for use by DEV WO_08815.
  2. Revision 3.5 is included with Solaris 2.5.1.
  3. Revision 3.6 is included with Patches 103351-01 (Solaris 2.3), 103290-02 (Solaris 2.4), and 103017-04 (Solaris 2.5).
  4. Revision 3.9 is included with Patches 103290-04 (Solaris 2.4), 103017-05 (Solaris 2.5), and 103766-02 (Solaris 2.5.1).

SSA Model 112 Array Controller Firmware

Part # U1202
Surface Mount
U1203
Surface Mount
U1204
Surface Mount
U1210
PLCC
Rev
501-2872-02 525-1437-01 525-1438-01 525-1435-01 525-1436-01
501-2872-02 Not released Not released Not released 525-1436-xx 3.3 1
501-2872-02 Not released Not released Not released 525-1436-xx 3.4 2
501-2872-03 525-1437-03 525-1438-03 525-1435-03 525-1436-02 3.4
Not released Not released Not released Not released 525-1436-xx 3.5 3
501-2872-04 525-1437-04 525-1438-04 525-1435-04 525-1436-02 3.6 4
501-4271-01 525-1437-04 525-1438-04 525-1435-04 525-1436-02 3.6 4
Not released Not released Not released Not released 525-1436-xx 3.9 5
501-2872-05 525-1437-05 525-1438-05 525-1435-05 525-1436-02 3.11
501-4271-02 525-1437-05 525-1438-05 525-1435-05 525-1436-02 3.11
501-2872-06 525-1437-07 525-1438-07 525-1435-07 525-1436-03 3.12
501-4271-03 525-1437-07 525-1438-07 525-1435-07 525-1436-03 3.12
  1. Revision 3.3 was approved for use by DEV WO_08658.
  2. Revision 3.4 was approved for use by DEV WO_08815.
  3. Revision 3.5 is included with Solaris 2.5.1.
  4. Revision 3.6 is included with Patches 103351-01 (Solaris 2.3), 103290-02 (Solaris 2.4), and 103017-04 (Solaris 2.5).
  5. Revision 3.9 is included with Patches 103290-04 (Solaris 2.4), 103017-05 (Solaris 2.5), and 103766-02 (Solaris 2.5.1).

SSA Model 200 Array Controller Firmware

Part # U1202
Surface Mount
U1203
Surface Mount
U1204
Surface Mount
U1210
PLCC
Rev
501-2651-01 525-1401-01 525-1402-01 525-1400-01 525-1405-01 1.9
501-2651-02 525-1367-06 525-1368-06 525-1365-06 525-1405-01 2.0
501-2651-03 525-1367-06 525-1368-06 525-1365-06 525-1405-02 2.0
Not released Not released Not released Not released 525-1405-xx 2.1
Not released Not released Not released Not released 525-1405-xx 2.3
501-2651-04 525-1367-07 525-1368-07 525-1365-07 525-1405-02 2.4
Not released Not released Not released Not released 525-1405-xx 3.3
Not released Not released Not released Not released 525-1405-xx 3.4 1
501-2651-05 525-1437-03 525-1438-03 525-1435-03 525-1405-02 3.4
Not released Not released Not released Not released 525-1405-xx 3.5 2
501-2651-06 525-1437-04 525-1438-04 525-1435-04 525-1405-02 3.6 3
Not released Not released Not released Not released 525-1405-xx 3.9 4
501-2651-07 525-1437-05 525-1438-05 525-1435-05 525-1405-02 3.11
501-2651-08 525-1437-07 525-1438-07 525-1435-07 525-1405-02 3.12
  1. This code was approved for use by DEV WO_08815.
  2. Release 3.5 is included with Solaris 2.5.1.
  3. Revision 3.6 is included with Patches 103351-01 (Solaris 2.3), 103290-02 (Solaris 2.4), and 103017-04 (Solaris 2.5).
  4. Revision 3.9 is included with Patches 103290-04 (Solaris 2.4), 103017-05 (Solaris 2.5), and 103766-02 (Solaris 2.5.1).

SSA Model 210 Array Controller Firmware

Part # U1202
Surface Mount
U1203
Surface Mount
U1204
Surface Mount
U1210
PLCC
Rev
501-3021-02 525-1437-01 525-1438-01 525-1435-01 525-1441-01
501-3021-02 Not released Not released Not released 525-1441-xx 3.3 1
501-3021-02 Not released Not released Not released 525-1441-xx 3.4 2
501-3021-03 525-1437-03 525-1438-03 525-1435-03 525-1441-02 3.4
Not released Not released Not released Not released 525-1441-xx 3.5 3
501-3021-04 525-1437-04 525-1438-04 525-1435-04 525-1441-02 3.6 4
Not released Not released Not released Not released 525-1441-xx 3.9 5
501-3021-05 525-1437-05 525-1438-05 525-1435-05 525-1441-02 3.11
501-3021-06 525-1437-07 525-1438-07 525-1435-07 525-1441-02 3.12
  1. Revision 3.3 was approved for use by DEV WO_08658.
  2. Revision 3.4 was approved for use by DEV WO_08815.
  3. Revision 3.5 is included with Solaris 2.5.1.
  4. Revision 3.6 is included with Patches 103351-01 (Solaris 2.3), 103290-02 (Solaris 2.4), and 103017-04 (Solaris 2.5).
  5. Revision 3.9 is included with Patches 103290-04 (Solaris 2.4), 103017-05 (Solaris 2.5), and 103766-02 (Solaris 2.5.1).




Firmware

Enterprise Network Array A5000
StorEdge A5000 / StorEdge A5100 / StorEdge A5200

FC100/FC-AL SBus Board Firmware
Assy Part # Part # U0202
PLCC Socket
Revision
540-2989-01 501-3060-02 525-1690-01 Pre-release
540-2989-01 501-3060-03 525-1690-01 Pre-release
540-2989-02 501-3060-04 525-1690-02 Unknown
Not used Not used 525-1690-03 Not used
540-2989-03 501-3060-05 525-1690-04 Unknown
540-2989-04 501-5202-01 525-1690-04 Unknown
540-2989-05 501-5266-01 525-1690-04 Unknown
None None None 1.10
540-2989-06 501-5266-02 525-1690-05 1.11
540-2989-06 501-5266-04 525-1690-06 1.13

Interface Board Firmware
Assy Part # Part # U0602
PLCC Socket
Revision
None 501-2951-04 525-1689-04 Pre-release
540-2988-01 501-2951-04 525-1689-05 Pre-release
540-2988-02 501-2951-05 525-1689-06 Unknown
540-2988-03 501-2951-06 525-1689-07 Unknown
Unknown Unknown Unknown 1.01
None None None 1.03 1
540-2988-04 501-2951-09 525-1689-08 1.05
540-2988-04 501-2951-10 525-1689-08 1.05
540-2988-05 501-2951-11 525-1689-09 1.07
540-2988-06 501-2951-12 525-1689-10 1.08
540-4033-01 501-5217-02 525-1689-10 1.08
540-2988-07 501-2951-13 525-1689-11 1.09
540-4033-02 501-5217-03 525-1689-11 1.09

Interconnect Board Firmware
Assy Part # Part # U0704
PLCC Socket
Revision
540-2864-04 501-2948-06 525-1691-02 Pre-release
540-2864-05 501-2948-07 525-1691-03 Unknown
540-2864-06 501-2948-08 525-1691-04 Unknown
540-2864-08 501-2948-09 525-1691-05 1.05
540-2864-09 501-2948-10 525-1691-06 1.07
540-2864-10 501-2948-11 525-1691-07 1.08
540-2864-11 501-2948-12 525-1691-08 1.09





Firmware

EXX00 I/O Board

I/O Type 1 Board - 512K x 8
U2501 Firmware Revision
525-1445-01 Pre-fcs
525-1445-02 Pre-fcs
525-1445-03 Pre-fcs
525-1445-04 Released by WO_09136
525-1445-05 1.7.0 + iPOST 3.2.2
525-1445-06 1.7.0 + iPOST 3.4.1 (adds FFB 501-3129 support)
525-1445-07 1.8.0 + iPOST 3.4.1 (fixes BugID 4011323)
525-1445-08 1.8.1 + iPOST 3.4.2 (fixes BugIDs 4011323 and 4024654)
525-1445-09 1.8.3 + iPOST 3.4.4
Older versions are compatible with AMD AM29F040 but
are not compatible with SGS Thompson AM29F040.
525-1445-10 1.8.3 + iPOST 3.4.6
525-1445-11 1.8.3 + iPOST 3.4.8 1998/10/27
525-1445-12 1.8.3 + iPOST 3.4.8 1999/02/19
None 1.8.22 + iPOST 3.4.22 (Patch 103346-22)
525-1445-13 1.8.23 + iPOST 3.4.23 1999/10/01
525-1445-14 1.8.24 + iPOST 3.4.24 1999/12/23
525-1445-15 1.8.25 + iPOST 3.4.25 2000/03/29 (WO_17418 cancelled)
525-1445-16 1.8.26 + iPOST 3.4.26 2000/05/09
525-1445-17 1.8.27 + iPOST 3.4.27 2000/08/29
525-1445-18 1.8.28 + iPOST 3.4.28 2000/12/12

I/O Type 2 Graphics Board - 512K x 8
U2501 Firmware Revision
525-1446-01 Pre-fcs
525-1446-02 Pre-fcs
525-1446-03 Pre-fcs
525-1446-04 Released by WO_09136
525-1446-05 1.7.0 + iPOST 3.2.2
525-1446-06 1.7.0 + iPOST 3.4.1 (adds FFB 501-3129 support)
525-1446-07 1.8.0 + iPOST 3.4.1 (fixes BugID 4011323)
525-1446-08 1.8.1 + iPOST 3.4.2 (fixes BugIDs 4011323 and 4024654)
525-1446-09 1.8.3 + iPOST 3.4.4
Older versions are compatible with AMD AM29F040 but
are not compatible with SGS Thompson AM29F040.
525-1446-10 1.8.3 + iPOST 3.4.6
525-1446-11 1.8.3 + iPOST 3.4.8 1998/10/27
525-1446-12 1.8.3 + iPOST 3.4.8 1999/02/19
None 1.8.22 + iPOST 3.4.22 (Patch 103346-22)
525-1446-13 1.8.23 + iPOST 3.4.23 1999/10/01
525-1446-14 1.8.24 + iPOST 3.4.24 1999/12/23
525-1446-15 1.8.25 + iPOST 3.4.25 2000/03/29 (WO_17418 cancelled)
525-1446-16 1.8.26 + iPOST 3.4.26 2000/05/09
525-1446-17 1.8.27 + iPOST 3.4.27 2000/08/29
525-1446-18 1.8.28 + iPOST 3.4.28 2000/12/12

PCI I/O Type 3 Board - 512K x 8
U2501 Firmware Revision
525-1680-01 1.8.7 + iPOST 3.0.2
525-1680-02 1.8.7 + iPOST 3.0.3
None 1.8.22 + iPOST 3.0.23 (Patch 103346-22)
525-1680-03 1.8.23 + iPOST 3.0.23 1999/10/01
525-1680-04 1.8.24 + iPOST 3.0.24 1999/12/23
525-1680-05 1.8.25 + iPOST 3.0.25 2000/03/29 (WO_17418 cancelled)
525-1680-06 1.8.26 + iPOST 3.0.26 2000/05/09
525-1680-07 1.8.27 + iPOST 3.0.27 2000/08/29
525-1680-08 1.8.28 + iPOST 3.0.28 2000/12/12

I/O Type 4 Board - 512K x 8
U2501 Firmware Revision
525-1757-01 1.8.6 + iPOST 3.4.4
525-1757-02 1.8.7 + iPOST unknown
525-1757-03 1.8.7 + iPOST 3.4.6
525-1757-04 1.8.7 + iPOST 3.4.8 1998/10/27
525-1757-05 1.8.7 + iPOST 3.4.8 1999/02/19
None 1.8.22 + iPOST 3.4.22 (Patch 103346-22)
525-1757-06 1.8.23 + iPOST 3.4.23 1999/10/01
525-1757-07 1.8.24 + iPOST 3.4.24 1999/12/23
525-1757-09 1.8.26 + iPOST 3.4.26 2000/05/09
525-1757-10 1.8.27 + iPOST 3.4.27 2000/08/29
525-1757-11 1.8.28 + iPOST 3.4.28 2000/12/12

I/O Graphics Type 5 Board - 512K x 8
U2501 Firmware Revision
525-1760-03 1.8.7 + iPOST 3.4.6
525-1760-04 1.8.7 + iPOST 3.4.8 1998/10/27
525-1760-05 1.8.7 + iPOST 3.4.8 1999/02/19
None 1.8.22 + iPOST 3.4.22 (Patch 103346-22)
525-1760-06 1.8.23 + iPOST 3.4.23 1999/10/01
525-1760-07 1.8.24 + iPOST 3.4.24 1999/12/23
525-1760-08 1.8.25 + iPOST 3.4.25 2000/03/29 (WO_17418 cancelled)
525-1760-09 1.8.26 + iPOST 3.4.26 2000/05/09
525-1760-10 1.8.27 + iPOST 3.4.27 2000/08/29
525-1760-11 1.8.28 + iPOST 3.4.28 2000/12/12





Firmware

Sun Fire 3800/4800/4810/6800

CPU/Memory Uniboard   cPCI I/O   PCI I/O
sgcpu.flash Unprogrammed Flash PROM 100-6321 with OBP + POST + Info
sgpci.flash Unprogrammed Flash PROM 100-5431 with iPOST + Info

System Controller
sgrtos.flash 525-1833
sgsc.flash 525-1881 / 525-1882 / 525-1883 / 525-1884
No Patch ScApp 5.11.3 + Info 5.11.3 + rtos V17A (WO_20260)
800054-01 ScApp 5.11.4 + Info 5.11.4 + rtos V17 (not ECO released) /TD>
111346-01 ScApp 5.11.6 + Info 5.11.6 + rtos V17 (not ECO released) /TD>
111346-02 ScApp 5.11.7 + Info 5.11.7 + rtos V17B (WO_21240)
111346-03 ScApp 5.11.8 + Info 5.11.7 + rtos V18 (not ECO released) /TD>
111346-04 ScApp 5.11.9 + Info 5.11.9 + rtos V18 (not ECO released) /TD>
112127-01 ScApp 5.12.5 + Info 5.12.5 + rtos V19 (called V19A in WO_22135)
112127-02 ScApp 5.12.6 + Info 5.12.6 + rtos V19 (called V20 in WO_23049)
112127-03 ScApp 5.12.7 + Info 5.12.7 + rtos V19 (not ECO released) /TD>
112494-04 ScApp 5.13.2 + Info 5.13.2 + rtos V23 (WO_24427)
112494-05 ScApp 5.13.3 + Info 5.13.3 + rtos V25 (not ECO released)
112494-06 ScApp 5.13.3 + Info 5.13.3 + rtos V26 (not ECO released)
112494-07 ScApp 5.13.4 + Info 5.13.4 + rtos V25 (not ECO released)
112494-08 ScApp 5.13.5 + Info 5.13.5 + rtos V25 (not ECO released) *
112883-01 ScApp 5.14.0 + Info 5.14.0 + rtos V26 (WO_25308)
112883-02 ScApp 5.14.1 + Info 5.14.1 + rtos V26 (WO_25664)
112883-03 ScApp 5.14.2 + Info 5.14.2 + rtos V26 (not ECO released)
112883-04 ScApp 5.14.3 + Info 5.14.3 + rtos V26 (WO_25792/WO_25977)
112883-05 ScApp 5.14.4 + Info 5.14.4 + rtos V26 (WO_25926/WO_26023)
112883-06 ScApp 5.14.5 + Info 5.14.5 + rtos V29 (not ECO released)
112883-07 ScApp 5.14.6 + Info 5.14.6 + rtos V31 (not ECO released)
112884-01 ScApp 5.15.0 + Info 5.15.0 + rtos V31 (WO_26563) **
112884-02 ScApp 5.15.1 + Info 5.15.1 + rtos V31 (WO_27048) **
112884-03 ScApp 5.15.2 + Info 5.15.2 + rtos V31 (WO_27389)
112884-04 ScApp 5.15.3 + Info 5.15.3 + rtos V32 (WO_27770)
112884-05 ScApp 5.15.4 + Info 5.15.3 + rtos V32 (not ECO released)
112884-06 ScApp 5.15.5 + Info 5.15.5 + rtos V39 (not ECO released)
* Adds support for UltraSPARC III (Cheetah++) 1.1. Refer to BugID 4808241.
** UltraSPARC III (Cheetah+) 2.2 and 2.3 pre-fetch is disabled. Refer to BugID 4889087.
Adds support for UltraSPARC IV (Jaguar) 3.x.





Firmware

Sun Fire 3800/4800/4810/6800
Sun Fire E4900/E6900

CPU/Memory Uniboard   cPCI I/O   PCI I/O
sgcpu.flash Unprogrammed Flash PROM 100-6321 with OBP + POST + Info
sgpci.flash Unprogrammed Flash PROM 100-5431 with iPOST + Info

System Controller
sgrtos.flash 525-1833
sgsc.flash 501-5563 / 501-5407:
  525-1881 / 525-1882 / 525-1883 / 525-1884

501-6631:
  100-7633 / 100-7633 / 100-7633 / 100-7633
114523-01 ScApp 5.16.0 + Info 5.16.0 + rtos V38 (WO_28770)
114523-02 ScApp 5.16.1 + Info 5.16.1 + rtos V40 (not ECO released)
114524-01 ScApp 5.17.0 + Info 5.17.0 + rtos V38 (WO_28982)
114524-02 ScApp 5.17.1 + Info 5.17.1 + rtos V39 (WO_29563)
114524-03 ScApp 5.17.2 + Info 5.17.2 + rtos V40 (not ECO released)
114524-04 ScApp 5.17.3 + Info 5.17.3 + rtos V41 (not ECO released)
114524-05 ScApp 5.17.4 + Info 5.17.4 + rtos V41 (not ECO released)
114524-06 ScApp 5.17.5 + Info 5.17.5 + rtos V41 (not ECO released)
114525-01 ScApp 5.18.0 + Info 5.18.0 + rtos V41 (WO_30158)
114525-02 ScApp 5.18.1 + Info 5.18.1 + rtos V41 (WO_30607)
114525-03 ScApp 5.18.2 + Info 5.18.2 + rtos V41 (WO_31112)
114525-04 ScApp 5.18.3 + Info 5.18.3 + rtos V41 (WO_31274)
114525-05 ScApp 5.18.4 + Info 5.18.4 + rtos V43 (not ECO released)
114525-06 ScApp 5.18.5 + Info 5.18.5 + rtos V45 (not ECO released)
114525-07 ScApp 5.18.6 + Info 5.18.6 + rtos V45 (not ECO released)
114526-01 ScApp 5.19.0 + Info 5.19.0 + rtos V43 (not ECO released)
114526-02 ScApp 5.19.1 + Info 5.19.1 + rtos V43 (WO_31463, WO_31777)
114526-03 ScApp 5.19.2 + Info 5.19.2 + rtos V43 (not ECO released) 1
114526-04 ScApp 5.19.3 + Info 5.19.3 + rtos V45 (not ECO released)
114526-05 ScApp 5.19.4 + Info 5.19.4 + rtos V45 (not ECO released)
114526-06 ScApp 5.19.5 + Info 5.19.5 + rtos V45 (not ECO released)
114526-07 ScApp 5.19.6 + Info 5.19.6 + rtos V45 (not ECO released)
114527-01 ScApp 5.20.0 + Info 5.20.0 + rtos V45 (not ECO released)
114527-02 ScApp 5.20.1 + Info 5.20.1 + rtos V45 (not ECO released)
114527-03 ScApp 5.20.2 + Info 5.20.2 + rtos V45 (not ECO released)
unknown ScApp 5.20.2 + Info 5.20.2 + rtos V46 (WO_33970)
114527-04 ScApp 5.20.3 + Info 5.20.3 + rtos V46 (WO_34720)
114527-05 ScApp 5.20.4 + Info 5.20.4 + rtos V46 (not ECO released)
114527-06 ScApp 5.20.5 + Info 5.20.5 + rtos V46 (WO_35393)
114527-07 ScApp 5.20.6 + Info 5.20.6 + rtos V46 (WO_37113)
114527-08 ScApp 5.20.7 + Info 5.20.7 + rtos V47
114527-09 ScApp 5.20.8 + Info 5.20.8 + rtos V47
114527-10 ScApp 5.20.9 + Info 5.20.9 + rtos V47 (not ECO released)
114527-11 ScApp 5.20.10 + Info 5.20.10 + rtos V47 (WO_39539)
114527-12 ScApp 5.20.11 + Info 5.20.11 + rtos V48 (WO_40157)
114527-13 ScApp 5.20.12 + Info 5.20.12 + rtos V48 (not ECO released)
114527-14 ScApp 5.20.13 + Info 5.20.13 + rtos V48 (not ECO released)
114527-15 ScApp 5.20.14 + Info 5.20.14 + rtos V49 (not ECO released)
114527-16 ScApp 5.20.15 + Info 5.20.15 + rtos V49 (not ECO released)
114527-17 ScApp 5.20.16 + Info 5.20.15 + rtos V49 (not ECO released)
114528-01 ScApp 5.21.0 + Info 5.21.0 + rtos V48 (not ECO released) 2
114528-02 ScApp 5.21.1 + Info 5.21.1 + rtos V48 (not ECO released) 2
1 Fixes 5.19.1 BugID 6319704.
2 Adds support for USBRDT 5240.
Obsoleted when USBRDT 5240 was announced as EOL .




Firmware

Netra 1280/1290 / Sun Fire V1280/E2900

CPU/Memory Uniboard   cPCI I/O   PCI I/O
sgcpu.flash Unprogrammed Flash PROM 100-6321 with OBP + POST + Info
sgpci.flash Unprogrammed Flash PROM 100-5431 with iPOST + Info

System Controller
sgrtos.flash 525-1833
2MB sgsc.flash 525-1881 / 525-1882 / 525-1883 / 525-1884
4MB sgsc.flash 525-2051 / 525-2052 / 525-2053 / 525-2054
254-0149-10 Binary Code V0.7
254-0170-10 Binary Code V0.9 (Patch 113751-01 ScApp:5.13.0009,RTOS:23)
254-0217-10 Binary Code V0.12 (Patch 113751-02 ScApp:5.13.0012,RTOS:23)
254-0217-11 Binary Code V0.13 (Patch 113751-03 ScApp:5.13.0013,RTOS:23)
254-0217-12 Binary Code V0.14 (Patch 113751-04 ScApp:5.13.0014,RTOS:32)
113751-05 ScApp 5.13.0015 + rtos V32 (not ECO released)
254-0331-10 ScApp 5.17.0 + rtos V38 (Patch 114524-01) (WO_28949)
254-0331-11 ScApp 5.17.1 + Info 5.17.1 + rtos V39 (Patch 114524-02) (WO_29490)
114524-03 ScApp 5.17.2 + Info 5.17.2 + rtos V40 (not ECO released)
114524-04 ScApp 5.17.3 + Info 5.17.3 + rtos V41 (not ECO released)
114524-05 ScApp 5.17.4 + Info 5.17.4 + rtos V41 (not ECO released)
114524-06 ScApp 5.17.5 + Info 5.17.5 + rtos V41 (not ECO released)
254-0365-10 ScApp 5.18.0 + Info 5.18.0 + rtos V41 (Patch 114525-01) (WO_30141)
254-0365-11 ScApp 5.18.1 + Info 5.18.1 + rtos V41 (Patch 114525-02) (WO_30560)
114525-03 ScApp 5.18.2 + Info 5.18.2 + rtos V41 (not ECO released)
254-0365-12 ScApp 5.18.3 + Info 5.18.3 + rtos V43 (Patch 114525-04) (WO_31241)
114525-05 ScApp 5.18.4 + Info 5.18.4 + rtos V43 (not ECO released)
114525-06 ScApp 5.18.5 + Info 5.18.5 + rtos V45 (not ECO released)
114525-07 ScApp 5.18.6 + Info 5.18.6 + rtos V45 (not ECO released)
254-0429-10 ScApp 5.19.0 + Info 5.19.0 + rtos V43 (Patch 114526-01) (WO_31446)
254-0429-11 ScApp 5.19.1 + Info 5.19.1 + rtos V43 (Patch 114526-02) (WO_31776)
254-0429-12 ScApp 5.19.2 + Info 5.19.2 + rtos V43 (Patch 114526-02) (WO_31852)
254-0429-13 ScApp 5.19.3 + Info 5.19.3 + rtos V45 (Patch 114526-03) (WO_31992) 1
254-0429-14 ScApp 5.19.4 + Info 5.19.4 + rtos V45 (Patch 114526-04) (WO_32425)
254-0429-15 ScApp 5.19.5 + Info 5.19.5 + rtos V45 (Patch 114526-05) (WO_32568)
114526-07 ScApp 5.19.6 + Info 5.19.6 + rtos V45 (not ECO released)
114526-08 ScApp 5.19.7 + Info 5.19.7 + rtos V45 (not ECO released)
114526-09 ScApp 5.19.8 + Info 5.19.8 + rtos V46 (not ECO released)
114527-01 ScApp 5.20.0 + Info 5.20.0 + rtos V45 (not ECO released) 2
114527-02 ScApp 5.20.1 + Info 5.20.1 + rtos V45 (not ECO released)
114527-03 ScApp 5.20.2 + Info 5.20.2 + rtos V45 (not ECO released)
unknown ScApp 5.20.2 + Info 5.20.2 + rtos V46 (WO_33970)
114527-04 ScApp 5.20.3 + Info 5.20.3 + rtos V46 (WO_34720)
114527-05 ScApp 5.20.4 + Info 5.20.4 + rtos V46 (not ECO released)
114527-06 ScApp 5.20.5 + Info 5.20.5 + rtos V46 (WO_35393) (WO_35650)
114527-07 ScApp 5.20.6 + Info 5.20.6 + rtos V46 (WO_37113)
114527-08 ScApp 5.20.7 + Info 5.20.7 + rtos V47 (WO_37660) (WO_37784)
114527-09 ScApp 5.20.8 + Info 5.20.8 + rtos V47 (WO_38395) (E2900)
114527-10 ScApp 5.20.9 + Info 5.20.9 + rtos V47 (not ECO released)
114527-11 ScApp 5.20.10 + Info 5.20.10 + rtos V47 (WO_39540) (E2900)
114527-11 ScApp 5.20.10 + Info 5.20.10 + rtos V47 (WO_39743) (Netra 1290)
114527-12 ScApp 5.20.11 + Info 5.20.11 + rtos V48 (not ECO released)
114527-13 ScApp 5.20.12 + Info 5.20.12 + rtos V48 (E2900) (WO_40763)
114527-13 ScApp 5.20.12 + Info 5.20.12 + rtos V48 (N1290) (WO_40844)
114527-14 ScApp 5.20.13 + Info 5.20.13 + rtos V48 (not ECO released)
114527-15 ScApp 5.20.14 + Info 5.20.14 + rtos V49 (not ECO released)
114527-16 ScApp 5.20.15 + Info 5.20.15 + rtos V49 (not ECO released)
114527-17 ScApp 5.20.16 + Info 5.20.15 + rtos V49 (not ECO released)
1 Fixes 5.19.1 BugID 6319704.
2 This was the first Netra 1290 firmware patch.




Firmware

StorEdge T3

StorEdge T3 Array Controller 375-0084
Options T3WG / T3ES / T3AES
Controller
Firmware
Interconnect
Firmware
EPROM
Flash
Patch Date
101a (1.01a) lpc_04.11 ep2_10 109115-01 03/00
114 (1.14) lpc_05.01 ep2_10 109115-02 07/00
114 (1.14) lpc_05.01 ep2_10 109115-03 09/00
116 (1.16) lpc_05.02 ep2_10 109115-04 11/00
116c (1.16c) lpc_05.02 ep2_10 109115-05 03/01
116c (1.16c) lpc_05.02 ep2_10 109115-06 04/01
117a (1.17a) lpc_05.02 ep2_10 109115-07 06/01
117a (1.17a) lpc_05.02 ep2_10 109115-08 06/01
117b (1.17b) lpc_05.02 ep2_10 109115-09 06/01
118 (1.18.00) lpc_05.02 ep2_10 109115-10 12/01
118 (1.18.00) lpc_05.02 ep2_10 109115-11 04/02
1181 (1.18.01) lpc_05.02 ep2_10 109115-12 12/02
1182 (1.18.02) lpc_05.02 ep2_10 109115-13 03/03
1182 (1.18.02) lpc_05.02 ep2_10 109115-14 10/03
1183 (1.18.03) lpc_05.02 ep2_10 109115-15 01/04
1183 (1.18.03) lpc_05.02 ep2_10 109115-16 02/04
1184 (1.18.04) lpc_05.02 ep2_10 109115-17 09/04
Firmware changes to 375-0084 were made without an ECO.


StorEdge T3+

StorEdge T3+ Array Controller 501-5710
Options T3BWG / T3BES / T3CWG / T3CES
Controller
Firmware
Interconnect
Firmware
EPROM
Flash
Patch Date
201 (2.00.01) lpc_05.02 ep2_10 112276-01 12/01
201 (2.00.01) lpc_05.02 ep2_10 112276-02 04/02
210 (2.01.00) lpc_05.02 ep2_10 112276-03 04/02
211 (2.01.01) lpc_05.02 ep2_10 112276-04 09/02
213 (2.01.03) lpc_05.02 ep2_10 112276-06 12/02
214 (2.01.04) lpc_05.02 ep2_10 112276-07 05/03
215 (2.01.05) lpc_05.02 ep2_10 112276-08 10/03
216 (2.01.06) lpc_05.02 ep2_10 112276-09 11/03
216 (2.01.06) lpc_05.02 ep2_10 112276-10 02/04
216 (2.01.06) lpc_05.02 ep2_10 112276-11 04/04
216 (2.01.06) lpc_05.02 ep2_10 112276-12 08/04
216 (2.01.06) lpc_05.02 ep2_10 112276-13 10/04
312 (3.01.02) lpc_05.02 ep2_10 115180-03 12/03
313 (3.01.03) lpc_05.02 ep2_10 115180-04 04/04
314 (3.01.04) lpc_05.02 ep2_10 115180-05 05/04
314 (3.01.04) lpc_05.02 ep2_10 115180-06 08/04
315 (3.01.05) lpc_05.02 ep2_10 115180-07 11/04
316 (3.01.06) lpc_05.02 ep2_10 115180-08 03/05
322 (3.02.02) lpc_05.02 ep2_10 116930-03 09/05
Firmware changes to 501-5710 were made without an ECO.




Firmware

StorEdge 3120

StorEdge 3120 JBOD I/O Module Firmware
Chassis Part Number SAF-TE ECO Patch
370-6195-01 1159 WO_28537 None
Not ECO released
1167 None 113728-01
370-6195-02 1170 WO_30806 113728-02
Not ECO released
1180 None 113728-03
Not ECO released
1190 None 113728-04

StorEdge 3310

StorEdge 3310 SCSI RAID Controller Firmware
Part Number RAID SAF-TE ECO Patch
370-5403-01 3.25N Unknown WO_24900 None
None 3.25O Unknown None 113722-01
370-5403-02 3.25Q Unknown WO_26787 113722-02
370-5403-03 3.25S Unknown WO_27822 113722-03
370-5403-03 3.25S 1159 WO_27822 113722-05 1 2
Not ECO Released
3.25W 1159 None 113722-06 1 2
Not ECO Released
3.25W 1169 None 113722-07 1 2
Not ECO Released
3.25W 1170 None 113722-09 2
370-5403-04 3.66
WO_30684 None
370-5403-05 3.66
WO_31084 None
Not ECO Released
411K 1170 None 113722-10
Not ECO Released
413B 1170 None 113722-11
Not ECO Released
413B 1180 None 113722-12
Not ECO Released
415F 1180 None 113722-15
Not ECO Released
415G 1180 None 113722-16
Not ECO Released
421E 1180 None 113722-17
Not ECO Released
423C 1180 None 113722-18
1 Version 1.5 of the sccli utility in the SUNWsccli package is required before patch installation.
2 Dual Ultra-3 SCSI Host Adapter 375-3057, Option 6758, requires
qus device driver Patch 112697-04 for Solaris 8 or Patch 112706-03 for Solaris 9.

StorEdge 3320

StorEdge 3320 Firmware
RAID SAF-TE ECO Patch
415G 1180 None 113730-01
415H 1180 None 113730-02
421D 1180 None 113730-03
421E 1185 None 113730-04

StorEdge 3510

StorEdge 3510 SCSI RAID I/O Module Firmware
Part Number RAID PLD SES ECO Patch
370-5537-01 327I Unknown Unknown WO_25829 None
370-5537-02 327K Unknown Unknown WO_26152 113723-01
Not ECO Released
327K Unknown 1000 None 113723-02
370-5537-03 327M 1000 1000 WO_26800 113723-03
Not ECO Released
327N 1000 1000 None 113723-04
370-5537-04 327P 1000 1000 WO_27359 113723-05
370-5537-05 327Q 1000 1030 WO_27900 113723-06
370-5537-06 327R 1000 1040 WO_28720 113723-07
Not ECO Released
327R 1000 1046 None 113723-09
370-5537-07 411G 1000 1046 WO_30684 None
370-5537-08 411I 1000 1046 WO_31075 113723-10
Not ECO Released
413C 1000 1046 None 113723-11
370-5537-08 Rev 52 413C 1000 1080 WO_35254 113723-14
Not ECO Released
415F 1000 1080 None 113723-15
Not ECO Released
415G 1000 1102 None 113723-17
Not ECO Released
421F 1000 1102 None 113723-18
Not ECO Released
415G 1000 1103 None 113723-19
Not ECO Released
421F 1000 1103 None 113723-20
Not ECO Released
423A 1000 1106 None 113723-21

StorEdge 3511

StorEdge 3511 SATA RAID I/O Module Firmware
Part Number RAID PLD SES ECO Patch
370-6773-01 327R 1000 403 WO_29091 None
Not ECO Released
327R 1000 412 None 113724-01
Not ECO Released
327R 1000 413 None 113724-03
370-6773-02 411G 1000 413 WO_30684 None
370-6773-03 411I 1000 413 WO_31075 113724-04
Not ECO Released
413C 1100 420 None 113724-05
370-6773-03 Rev 52 413C 1100 420 WO_32524 113724-08
Not ECO Released
415F 1100 430 None 113724-09
Not ECO Released
415G 1100 430 None 113724-10
Not ECO Released
421F 1100 430 None 113724-11
Not ECO Released
423A 1100 440 None 113724-12


StorEdge 6020 / 6120

StorEdge 6020 / 6120 RAID Controller Firmware
Part Number Firmware ECO Patch Patch Date
540-5559-03 3.0.3 WO_25897 None None
Not ECO Released
3.0.6 None 114285-07 08/21/03
540-5559-03 3.0.7 WO_27879 1 114285-08 10/21/03
540-5559-04 3.0.7 WO_27780 2 114285-08 10/21/03
Not ECO Released
3.1.0 None 115179-01 11/26/03
Not ECO Released
3.1.1 None 115179-03 12/03/03
Not ECO Released
3.1.2 None 115179-04 01/16/04
Not ECO Released
3.1.3 None 115179-06 04/30/04
Not ECO Released
3.1.4 None 115179-11 05/28/04
Not ECO Released
3.1.5 None 115179-12 11/28/04
Not ECO Released
3.1.6 None 115179-13 03/16/05
Not ECO Released
3.2.0 None None None
Not ECO Released
3.2.1 None None None
Not ECO Released
3.2.2 None 116931-18 09/06/05
Not ECO Released
3.2.3 None 116931-19 01/30/06
Not ECO Released
3.2.4 None 116931-20 3 06/30/06
Not ECO Released
3.2.5 None 116931-21 09/12/06
Not ECO Released
3.2.6 None 116931-22 03/12/07
Not ECO Released
3.2.7 None 116931-23 08/31/07
1 Deviation wo_27879 shipped 2000 boards with firmware 3.0.7 in October 2003.
2 The last firmware change to FRU F540-5559 was WO_27780 in December 2003.
3 Patch 116931-20 was withdrawn from distribution.




Firmware

Multi-Fabric Network Express Module

NEM + Board 501-7845

525-2884-01 LSI Expander Firmware 5.02.14 (WO_41529)
525-2884-02 LSI Expander Firmware 5.04.03 (SW2.1) (WO_42875)

Virtualized Multi-Fabric Network Express Module

Hydra NEM Board 501-7995

525-2539-04 LSI Expander Firmware 2.0.2 (WO_38599)
525-2539-05 LSI Expander Firmware 5.02.10 (WO_39734)
525-2539-06 LSI Expander Firmware 5.02.14 (WO_40521)
525-2539-07 LSI Expander Firmware 5.04.03 (SW2.1) (WO_42875)

Virtualized Multi-Fabric M2 Network Express Module

Hydra2 NEM Board 511-1365 / 540-7963

525-2808-04 LSI Expander Firmware 5.03.05.00 (WO_42457)
525-2808-05 LSI Expander Firmware 5.03.06.00 (SW 1.0.1) (WO_43616)
525-2808-06 LSI Expander Firmware 5.03.07.00 (SW 1.1) (E0000076))




Firmware

1Gb/Sec SBus Dual Fibre Channel Host Adapter

375-3048-01 Rev 50
375-3048-01 Rev 51
375-3048-02 Rev 50
375-3048-02 Rev 51
375-3048-02 Rev 52
Dual Channel Adapter w Firmware 1.13.04
Dual Channel Adapter w Firmware 1.13.06 (Patch 112244-01)
Dual Channel Adapter w Firmware 1.13.07 (Patch 112244-02)
Dual Channel Adapter w Firmware 1.14.00 (Patch 112244-03)
Dual Channel Adapter w Firmware 1.14.05 (Patch 112244-04)

1Gb/Sec PCI Single Fibre Channel Network Adapter

375-3019-01 Rev 50
375-3019-01 Rev 51
375-3019-01 Rev 52
375-3019-01 Rev 53
375-3019-01 Rev 54
Single Channel Adapter w Firmware x.x
Single Channel Adapter w Firmware 1.13 (Patch 111853-01)
Single Channel Adapter w Firmware 1.14.02 (Patch 111853-02)
Single Channel Adapter w Firmware 1.14.09 (Patch 111853-03)
Single Channel Adapter w Firmware 1.14.10 ((Patch 111853-04)

1Gb/Sec PCI Dual Fibre Channel Network Adapter+

375-3030-01 Rev 50
375-3030-01 Rev 51
375-3030-01 Rev 52
375-3030-01 Rev 53
375-3030-01 Rev 54
Dual Channel Adapter w Firmware x.x
Dual Channel Adapter w Firmware 1.13 (Patch 111853-01)
Dual Channel Adapter w Firmware 1.14.02 (Patch 111853-02)
Dual Channel Adapter w Firmware 1.14.09 (Patch 111853-03)
Dual Channel Adapter w Firmware 1.14.10 (Patch 111853-04)

1Gb/Sec cPCI Dual Fibre Channel Network Adapter

375-0118-01 Rev 50
375-0118-01 Rev 51
375-0118-01 Rev 52
375-0118-01 Rev 53
375-0118-01 Rev 54
Dual Channel Adapter w Firmware x.x
Dual Channel Adapter w Firmware 1.13 (Patch 111853-01)
Dual Channel Adapter w Firmware 1.14.09 (Patch 111853-02)
Dual Channel Adapter w Firmware 1.14.09 (Patch 111853-03)
Dual Channel Adapter w Firmware 1.14.10 (Patch 111853-04)

2Gb/Sec PCI Single Fibre Channel Host Adapter

375-3102-01 Rev 50
375-3102-01 Rev 51
375-3102-01 Rev 52
375-3102-01 Rev 53
375-3102-01 Rev 54
Not ECO Released
Single Channel Adapter w Firmware x.x
Single Channel Adapter w Firmware 1.14.01 (Patch 114873-01)
Single Channel Adapter w Firmware 1.14.09 (Patch 114873-02)
Single Channel Adapter w Firmware 1.14.11 (Patch 114873-03)
Single Channel Adapter w Firmware 1.14.15 (Patch 114873-04)
Single Channel Adapter w Firmware 1.16 (Patch 114873-05)

2Gb/Sec PCI-X Single Fibre Channel Host Adapter

375-3383-01 Rev 50
375-3383-01 Rev 51
375-3383-01 Rev 52
375-3383-01 Rev 54
Single Channel Adapter w Firmware 1.14.09
Single Channel Adapter w Firmware 1.14.11 (Patch 114874-03)
Single Channel Adapter w Firmware 1.14.15 (Patch 114874-04)
Single Channel Adapter w Firmware 1.16 (Patch 114874-05)

2Gb/Sec Single Fibre Channel Network Adapter (JNI)

375-3156-01 Rev 51
375-3156-01 Rev 52
375-3156-01 Rev 53
Single Channel Adapter w Firmware 1.1 (Patch 116423-01) 1
Single Channel Adapter w Firmware 1.2 (Patch 116423-02) 2
Single Channel Adapter w Firmware 1.5.2 (Patch 116423-03) 3
1 Fixes BugIDs 4883616, 4896819, 4894526, 4897505.
2 Fixes BugIDs 4938847 and 4894952. Adds SAN 4.4 support.
3Fixes BugIDs 4988988, 5026034, 5048398, and 5051259. Adds SAN 4.4.2 support.

2Gb/Sec PCI-X Single Fibre Channel Network Adapter (LP10000)

375-3305-01 Rev 50
375-3305-01 Rev 51
375-3305-01 Rev 52
375-3305-01 Rev 53
Not ECO Released
Not ECO Released
Dual Channel Adapter w Firmware 5.01a4
Dual Channel Adapter w Firmware 5.01a4
Dual Channel Adapter w Firmware 5.01a8 (Patch 121773-01) 1
Single Channel Adapter w Firmware 5.02a1 (Patch 121773-02)
Single Channel Adapter w Firmware 5.02a1 (Patch 121773-03)
Single Channel Adapter w Firmware 5.03a0 (Patch 121773-04)
1 Fixes BugIDs 6281250, 6315282, 6333168, 6235226, 6254142, 6262395, 6313785.

2Gb/Sec PCI Dual Fibre Channel Network Adapter

375-3108-01 Rev 50
375-3108-01 Rev 51
375-3108-01 Rev 52
375-3108-02 Rev 51
375-3108-02 Rev 52
Dual Channel Adapter w Firmware x.x
Dual Channel Adapter w Firmware 1.14.01 (Patch 114874-01)
Dual Channel Adapter w Firmware 1.14.09 (Patch 114874-02)
Dual Channel Adapter w Firmware 1.14.11 (Patch 114874-03)
Dual Channel Adapter w Firmware 1.14.15 (Patch 114874-04)

2Gb/Sec PCI Dual Fibre Channel Network Adapter

375-3363-01 Rev 50
375-3363-01 Rev 51
375-3363-01 Rev 52
375-3363-01 Rev 54
Dual Channel Adapter w Firmware 1.14.09
Dual Channel Adapter w Firmware 1.14.11 (Patch 114874-03)
Dual Channel Adapter w Firmware 1.14.15 (Patch 114874-04)
Dual Channel Adapter w Firmware 1.16 (Patch 114874-05)

2Gb/Sec Dual Fibre Channel Network Adapter (JNI)

375-3157-01 Rev 51
375-3157-01 Rev 52
375-3157-01 Rev 53
Dual Channel Adapter w Firmware 1.1 (Patch 116423-01) 1
Dual Channel Adapter w Firmware 1.2 (Patch 116423-02) 1
Dual Channel Adapter w Firmware 1.5.2 (Patch 116423-03) 2
1 Adds SAN 4.4 support.
2 Adds SAN 4.4.2 support.

2Gb/Sec PCI-X Dual Fibre Channel Network Adapter (LP10000)

375-3304-01 Rev 50
375-3304-01 Rev 51
375-3304-01 Rev 52
Not ECO Released
Not ECO Released
Not ECO Released
Dual Channel Adapter w Firmware 5.01a4
Dual Channel Adapter w Firmware 5.01a4
Dual Channel Adapter w Firmware 5.01a8 (Patch 121773-01)
Dual Channel Adapter w Firmware 5.02a1 (Patch 121773-02)
Dual Channel Adapter w Firmware 5.02a1 (Patch 121773-03)
Dual Channel Adapter w Firmware 5.03a0 (Patch 121773-04)

4Gigabit/Sec Single PCI-X Fibre Channel Network Adapter

375-3354-01
123305-01
375-3354-01 Rev 52
123305-03
375-3354-01 Rev 53
QLA2460 w FCode x.x/BIOS x.x
QLA2460 w FCode 1.17/BIOS 1.15 (not ECO released)
QLA2460 w FCode 1.24/BIOS 1.24 (Patch 123305-02) (WO_35327)
QLA2460 w FCode 1.26/BIOS 1.24 (not ECO released)
QLA2460 w FCode 2.01/BIOS 2.02 (Patch 123305-04) (WO_40184)

4Gigabit/Sec Dual PCI-X Fibre Channel Network Adapter

375-3294-01
123305-01
375-3294-01 Rev 52
123305-03
375-3294-01 Rev 53
QLA2462 w FCode x.x/BIOS x.x
QLA2462 w FCode 1.17/BIOS 1.15 (not ECO released)
QLA2462 w FCode 1.24/BIOS 1.24 (Patch 123305-02) (WO_35327)
QLA2462 w FCode 1.26/BIOS 1.24 (not ECO released)
QLA2462 w FCode 2.01/BIOS 2.02 (Patch 123305-04) (WO_40184)

4Gigabit/Sec Single PCIe Fibre Channel Network Adapter

375-3355-01
123305-01
375-3355-01 Rev 51
123305-03
375-3355-02 Rev 51
QLE2460 w FCode x.x/BIOS x.x
QLE2460 w FCode 1.17/BIOS 1.15 (not ECO released)
QLE2460 w FCode 1.24/BIOS 1.24 (Patch 123305-02) (WO_35327)
QLE2460 w FCode 1.26/BIOS 1.24 (not ECO released)
QLA2460 w FCode 2.01/BIOS 2.02 (Patch 123305-04) (WO_40184)

4Gigabit/Sec Dual PCIe Fibre Channel Network Adapter

375-3356-01
123305-01
375-3356-01 Rev 51
123305-03
375-3356-02 Rev 51
QLE2462 w FCode x.x/BIOS x.x
QLE2462 w FCode 1.17/BIOS 1.15 (not ECO released)
QLE2462 w FCode 1.24/BIOS 1.24 (Patch 123305-02) (WO_35327)
QLE2462 w FCode 1.26/BIOS 1.24 (not ECO released)
QLE2462 w FCode 2.01/BIOS 2.02 (Patch 123305-04) (WO_40184)

4Gigabit/Sec Dual PCIe Fibre Channel Network Adapter

375-3384-01
375-3384-02 Rev 51
123305-03
375-3384-03 Rev 51
QLE2462 w FCode x.x/BIOS x.x (WO_32436)
QLE2462 w FCode 1.24/BIOS 1.24 (Patch 123305-02) (WO_35327)
QLE2462 w FCode 1.26/BIOS 1.24 (not ECO released)
QLE2462 w FCode 2.01/BIOS 2.02 (Patch 123305-04) (WO_40184)

8Gigabit/Sec Single PCIe Fibre Channel Network Adapter

371-4295-01
143247-02
LPE12000-S Firmware unknown (WO_39701)
LPE12000-S FCode 3.10a3/BIOS 2.11a2 (not ECO released)

8Gigabit/Sec Dual PCIe Fibre Channel Network Adapter

371-4306-01
143247-02
LPE12002-S Firmware unknown (WO_39701)
LPE12002-S FCode 3.10a3/BIOS 2.11a2 (not ECO released)




Dual Ultra-320 SCSI Host Bus Adapter

375-3191-01 Rev 50
375-3191-01 Rev 51
126323-01
126323-03
Dual Ultra-320 Adapter w Firmware x.x
Dual Ultra-320 Adapter w Firmware 1.03.27
FCode 1.13 (not ECO released)
FCode 1.14 (not ECO released)

8-Port SAS/SATA Host Bus Adapter

375-3487-03
375-3487-04
Update to NVDATA 2B.03 (WO_38935)
Update to Firmware 14 (WO_39974)




Firmware

Brocade Silkworm

119552-01
119552-02
119552-03
119552-04
122185-01
122185-02
124898-01
140810-01
140810-02
140810-03
140810-04
140810-05
140810-06
142801-01
FOS 5.0.1a for 12000
FOS 5.0.3a for 12000
FOS 5.0.4a for 12000
FOS 5.0.5b for 12000
FOS 5.1.0a for 200E/3250/3850/3900/4100/24000/48000
FOS 5.1.0d for 200E/3250/3850/3900/4100/7500/24000/48000
FOS 5.2.0a for 200E/3250/3850/3900/4100/7500/24000/48000
FOS 6.2.0a for 200E/300/4100/4900/5000/5100/5300/7500/7500E/48000/DCX/DCX-4S
FOS 6.2.0c for 200E/300/4100/4900/5000/5100/5300/7500/7500E/48000/DCX/DCX-4S
FOS 6.2.0e for 200E/300/4100/4900/5000/5100/5300/7500/7500E/48000/DCX/DCX-4S
FOS 6.2.0g for 200E/300/4100/4900/5000/5100/5300/7500/7500E/48000/DCX/DCX-4S
FOS 6.2.1 for 200E/300/4100/4900/5000/5100/5300/7500/7500E/48000/DCX/DCX-4S
FOS 6.2.1b for 200E/300/4100/4900/5000/5100/5300/7500/7500E/48000/DCX/DCX-4S
FOS 6.3.0a for 300/4100/4900/5000/5100/5300/7500/7500E/7500E/7800/8000/48000/DCX/DCX-4S

PCI Express Quad Gigabit Ethernet UTP

501-7606-03
501-7606-04
QGE w Firmware 2.x 520-3799-02
QGE w Firmware 2.8 520-3799-03

RAID Expansion Module

511-1098-01
511-1098-02
Firmware 1.25.00.00 525-2616-02
Firmware 1.24.94.00 525-2616-03 1 2
1 Adds support for Sun Blade 6000 Disk Module and NEM option X4212A.
2 Adds support for NEM option X4236A with VNP.

Flash Accelerator F20

Aura FMod 371-4415
371-4415-01
371-4415-02
371-4415-03
Firmware DP0I (WO_42074)
Firmware DP0N (WO_42230)
Firmware D20R (WO_42283)

  Copyright � 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback