Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|||
FDK PEX733/PEX794
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Servers: | Enterprise 150 Netra i 150, nfs 150 |
| Disk Arrays: | SPARCstorage MultiPack StorEdge MultiPack |
| 300-1330 | 300-1531 |
|---|---|
|
Type A104 AC Input Power Supply FDK PEX733 |
Type A156 AC Input Power Supply FDK PEX794 |
| PIN | DESCRIPTION | PIN | DESCRIPTION |
|---|---|---|---|
| 1 | +5Vdc | 10 | +5Vdc |
| 2 | +5Vdc | 11 | +5Vdc |
| 3 | Gnd | 12 | Gnd |
| 4 | Gnd | 13 | Gnd |
| 5 | +5V pre-charge | 14 | +12V pre-charge |
| 6 | Gnd | 15 | Gnd |
| 7 | Gnd | 16 | Gnd |
| 8 | +12Vdc | 17 | +12Vdc |
| 9 | +12Vdc | 18 | +12Vdc |
| 100-240V | 47-63Hz | 3.0A |
| +5V | +12V |
| 15.0A | 12.0A |
|