Sun Microsystems, Inc.   Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Boot PROM
UltraSPARC I / II / IIe / IIi

Ultra 1 Model 140 (A11)
Ultra 1 Model 170 (A11)
Ultra 1 Model 140E (A12)
Ultra 1 Model 170E (A12)
Ultra 1 Model 200E (A12)
Ultra 2 (A14)
Ultra 5 (A21) / Ultra 10 (A22)
Ultra 30 (A16) (Netra t 1100)
Ultra 60 (A23) (Enterprise 220R / Netra t 1120/1125)
Ultra 80 (A27) (Enterprise 420R / Netra t 1400/1405)
Enterprise 250 (A26)
Ultra 450 (A20) / Ultra Enterprise 450 (A25)
Enterprise 3000/4000/5000/6000
Enterprise 3500/4500/5500/6500
Sun Blade 100 (A36)
Sun Blade 150 (A41)
Sun Fire V100
Netra 120 / Sun Fire V120
Netra t1 Model 100/105
Netra T1 AC200/DC200
Netra ct 400/800
Netra X1


Ultra 1 Model 140

512K × 8 (Patch 104881)

Patch Readmes and Downloads

U2003 Flash PROM Revision
525-1410-01 OBP 3.0 Version 2 + POST 2.0.4
525-1410-02 OBP 3.0 Version 4 + POST 2.0.4
525-1410-03 OBP 3.1 Version 1 + POST 3.10.2 (128MB SIMM support)
525-1410-04 OBP 3.1 Version 2 + POST 3.10.6 (not released)
525-1410-05 OBP 3.5 Version 0 + POST 3.10.6 (1229983 & 4018056)
525-1410-06 OBP 3.11 Version 1 + POST 3.10.6
Required for Solaris 7 64-bit operating system
104881-07 OBP 3.25 Version 0 + POST 3.10.6 (Flash Update 2.2)

Ultra 1 Model 170

512K × 8 (Patch 104881)

Patch Readmes and Downloads

U2003 Flash PROM Revision
525-1448-01 OBP 3.0 Version 0 + POST 2.0.4
525-1448-02 OBP 3.0 Version 2 + POST 2.0.4
525-1448-03 OBP 3.1 Version 1 + POST 3.10.2 (128MB SIMM support)
525-1448-04 OBP 3.1 Version 2 + POST 3.10.6 (not released)
525-1448-05 OBP 3.5 Version 0 + POST 3.10.6 (1229983 & 4018056)
525-1448-06 OBP 3.11 Version 1 + POST 3.10.6
Required for Solaris 7 64-bit operating system
104881-07 OBP 3.25 Version 0 + POST 3.10.6 (Flash Update 2.2)

Ultra 1 Model 140E

512K × 8 (Patch 104288)

Patch Readmes and Downloads

U2003 Flash PROM Revision
525-1681-01
525-1681-02 OBP 3.3 Version 3 + POST 3.10.6
525-1681-03 Not released
525-1681-04 OBP 3.5 Version 1 + POST 3.10.6 (not released)
525-1681-05 OBP 3.7 Version 1 + POST 3.11.4 (supports Rev3 PHY)
525-1681-06 OBP 3.11 Version 1 + POST 3.11.4
Required for Solaris 7 64-bit operating system
104288-07 OBP 3.25 Version 0 + POST 3.11.4 (Flash Update 2.2)

Ultra 1 Model 170E

512K × 8 (Patch 104288)

Patch Readmes and Downloads

U2003 Flash PROM Revision
525-1411-01 OBP 3.0 Beta3 Version 3
525-1411-01 OBP 3.0 Beta4 Version 0
525-1411-02 OBP 3.0 Version 4 + POST 2.0.6
525-1411-03 OBP 3.1 Version 2 + POST 3.10.2
525-1411-04 Not released
525-1411-05 OBP 3.5 Version 1 + POST 3.10.6 (not released)
None OBP 3.5 Version 2 + POST 3.10.6 (on Flash Update 1.5)
525-1411-06 OBP 3.7 Version 1 + POST 3.11.4 (supports Rev3 PHY)
525-1411-07 OBP 3.11 Version 1 + POST 3.11.4
Required for Solaris 7 64-bit operating system
104288-07 OBP 3.25 Version 0 + POST 3.11.4 (Flash Update 2.2)

Ultra 1 Model 200E

512K × 8 (Patch 104288)

Patch Readmes and Downloads

U2003 Flash PROM Revision
525-1662-01 OBP 3.3 Alpha1 Version 0 + POST 3.10.2 (P0 build)
525-1662-02 OBP 3.3 Alpha2 Version 2 + POST 3.10.3 (P2 build)
525-1662-03 OBP 3.3 Version 2 + POST 3.10.3 (FCS build)
525-1662-04 Not released
525-1662-05 OBP 3.5 Version 1 + POST 3.10.6 (not released)
525-1662-06 OBP 3.7 Version 1 + POST 3.11.4 (supports Rev3 PHY)
525-1662-07 OBP 3.11 Version 1 + POST 3.11.4
Required for Solaris 7 64-bit operating system
104288-07 OBP 3.25 Version 0 + POST 3.11.4 (Flash Update 2.2)


Ultra 2

512K × 8 (Patch 104169)

Patch Readmes and Downloads

U2003 Flash PROM Revision
525-1414-01 OBP 3.0 Beta4 Version 4 (P1.2 build)
525-1414-01 OBP 3.0 Alpha1 Version 1 (P1.3 build)
525-1414-01 OBP 3.1 Alpha1 Version 2 + POST 1.1.9 (P1.4 /P2.0 build)
525-1414-02 OBP 3.1 Beta1 Version 0 + POST 2.1.1 (200MHz support)
525-1414-03 OBP 3.1 Version 2 + POST 3.1.3 or 3.1.4
525-1414-04 OBP 3.1.3 Version 3 + POST 3.1.4
525-1414-05 OBP 3.1.3 Version 3 + POST 3.1.5 (not released)
525-1414-06 OBP 3.1.4 Version 4 + POST 3.1.5 (not released)
525-1414-07 OBP 3.1.5 Version 5 + POST 3.1.5 (Flash Update 1.3)
None OBP 3.1 Version 6 + POST 3.1.5
525-1414-08 OBP 3.5 Version 2 + POST 3.1.5 (not released)
525-1414-09 OBP 3.7 Version 0 + POST 3.2.1
525-1414-10 OBP 3.11 Version 2 + POST 3.3.5 (not structured)
525-1414-11 OBP 3.11 Version 2 + POST 3.3.7
525-1414-12 OBP 3.11 Version 2 + POST 3.3.8
525-1414-13 OBP 3.19 Version 0 + POST 3.3.8
104169-08 OBP 3.25 Version 0 + POST 3.3.8 (Flash Update 2.2)

Ultra 2 PROM Changes
DASH DESCRIPTION
-02 Adds support for 200MHz UltraSPARC
-04 Previous OBP versions set the UPA speed to 148MHz when
2.2 and 4.0 UltraSPARC processors are mixed.
-07 Fixes wrong SIMM pair error reporting BugID 1262941.
Reports memory errors as a single SIMM.
Available in Flash Update 1.3 and Patch 104169-03.
-09 Fixes BugIDs 1229983 and 4018056.
Adds support for 300MHz UltraSPARC II.
Power down if mixed modules are installed.
-10 Not structured because of POST external cache ram crosstalk
test BugIDs 4115766 and 4116867. Included on Flash Update
1.7. Required for Solaris 2.7 64-bit operating system.
-11 Removed external cache ram crosstalk test.
-12 Adds support for 400MHz UltraSPARC II.
-13 Fixes BugIDs 4004140, 4129194, 4145990, and 4203848.
Adds tape drive boot support and UXFL support.


Ultra 5 / Ultra 10

1M × 8

System Board 375-0009 (Patch 106121)

Sun Ultra 5 Workstation Patch Readmes and Downloads
Sun Ultra 10 Workstation Patch Readmes and Downloads

U2703 Flash Boot PROM Revision
370-3202-01 OBP 3.11 Version 2 + POST 2.2.2 + OBDIAG 2.2
370-3202-02 OBP 3.11 Version 5 + POST 2.2.2 + OBDIAG 2.2
370-3202-03 OBP 3.11 Version 6 + POST 2.2.8 + OBDIAG 2.5
370-3202-04 OBP 3.11 Version 7 + POST 2.2.8 + OBDIAG 2.6
370-3202-05 OBP 3.11 Version 9 + POST 2.2.9 + OBDIAG 2.6
370-3202-06 OBP 3.11 Version 12 + POST 2.2.9 + OBDIAG 2.6
370-3886-03 OBP 3.19 Version 4 + POST 3.0.7 + OBDIAG 2.8
370-3886-08 OBP 3.31 Version 0 + POST 3.1.0 + OBDIAG 2.8 (WO_29074)

Ultra 5 / Ultra 10 - 1M × 8
System Board 375-0066
(Patch 106121)

Sun Ultra 5 Workstation Patch Readmes and Downloads
Sun Ultra 10 Workstation Patch Readmes and Downloads

U2703 Flash Boot PROM Revision
370-3697-02 OBP 3.15 Version 2
370-3886-03 OBP 3.19 Version 4 + POST 3.0.7 + OBDIAG 2.8
370-3886-04 OBP 3.25 Version 1 + POST 3.0.8 + OBDIAG 2.8
370-3886-06 OBP 3.25 Version 3 + POST 3.0.9 + OBDIAG 2.8
370-3886-07 OBP 3.29 Version 3 + POST 3.1.0 + OBDIAG 2.8
370-3886-08 OBP 3.31 Version 0 + POST 3.1.0 + OBDIAG 2.8 (WO_22830)

Ultra 5 / Ultra 10 - 1M × 8
System Board 375-0079
(Patch 106121)

Sun Ultra 5 Workstation Patch Readmes and Downloads
Sun Ultra 10 Workstation Patch Readmes and Downloads

U2703 Flash Boot PROM Revision
370-3886-01 OBP 3.19 Version 0
370-3886-02 OBP 3.19 Version 2 + POST 3.0.5
370-3886-03 OBP 3.19 Version 4 + POST 3.0.7 + OBDIAG 2.8
370-3886-04 OBP 3.25 Version 1 + POST 3.0.8 + OBDIAG 2.8
370-3886-05 OBP 3.25 Version 2 + POST 3.0.9 + OBDIAG 2.8
370-3886-06 OBP 3.25 Version 3 + POST 3.0.9 + OBDIAG 2.8
370-3886-07 OBP 3.29 Version 3 + POST 3.1.0 + OBDIAG 2.8
370-3886-08 OBP 3.31 Version 0 + POST 3.1.0 + OBDIAG 2.8 (WO_22830)

Ultra 5 / Ultra 10 - 1M × 8
System Board 375-0115
(Patch 106121)

Sun Ultra 5 Workstation Patch Readmes and Downloads
Sun Ultra 10 Workstation Patch Readmes and Downloads

U2703 Flash Boot PROM Revision
370-3886-04 OBP 3.25 Version 1 + POST 3.0.8 + OBDIAG 2.8
370-3886-05 OBP 3.25 Version 2 + POST 3.0.9 + OBDIAG 2.8
370-3886-06 OBP 3.25 Version 3 + POST 3.0.9 + OBDIAG 2.8
106121-13 OBP 3.27 Version 0 + POST 3.1.0 + OBDIAG 2.8
370-3886-07 OBP 3.29 Version 0 + POST 3.1.0 + OBDIAG 2.8
370-3886-08 OBP 3.31 Version 0 + POST 3.1.0 + OBDIAG 2.8 (WO_22830)

Ultra 5 / Ultra 10 - 1M × 8
System Board 375-3060
(Patch 106121)

Sun Ultra 5 Workstation Patch Readmes and Downloads
Sun Ultra 10 Workstation Patch Readmes and Downloads

U2703 Flash Boot PROM Revision
370-3886-08 OBP 3.31 Version 0 + POST 3.1.0 + OBDIAG 2.8 (WO_22830)

Ultra 5 and Ultra 10 PROM Changes
DASH DESCRIPTION
3886-03 DRAM timing change for 333/360/440MHz Sapphire Red
3886-04 DRAM timing change for 400MHz Sapphire Red
3886-05 DRAM timing change for 440MHz Sapphire Red
3886-06 Micron MTxLDxx72FG-5 EDO timing change for 360-440MHz
3886-07 Supports MAC address 00:03:BA:xx:xx:xx


Ultra 30 / Netra t 1100

1M × 8 (Patch 105930)

Ultra 30 Patch Readmes and Downloads

U2003 Flash Boot PROM Revision
525-1669-01 Pre-FCS
525-1669-02 OBP 3.5.3 Pre-FCS
525-1669-03 OBP 3.5.0 Pre-FCS
525-1669-04 OBP 3.5.5 Pre-FCS
525-1669-05 OBP 3.5.10 Pre-FCS
525-1669-06 OBP 3.5.0 Pre-FCS
525-1669-07 OBP 3.5 P2.0 Version 16 1
525-1669-08 OBP 3.5 Version 17
525-1669-09 OBP 3.5 Version 17
525-1669-10 OBP 3.9 Version 4 + POST 1.1.1 + OBDIAG 2.1.1
525-1669-11 OBP 3.9 Version 5 + POST 1.1.1 + OBDIAG 2.1.1
525-1669-12 OBP 3.11 Version 1 + POST 1.1.1 + OBDIAG 2.1.1 2
525-1669-13 OBP 3.11 Version 1 + POST 1.1.1 + OBDIAG 2.2 3
525-1669-14 OBP 3.11 Version 2 + POST 1.1.1 + OBDIAG 2.2
105930-05 OBP 3.25 Version 0 + POST 1.1.1 + OBDIAG 2.2
105930-06 OBP 3.27 Version 0 + POST 1.1.1 + OBDIAG 2.2

Ultra 30 PROM Changes
DASH DESCRIPTION
-14 Fixes Symbios SCSI controller booting BugID 4114784
-14 Changed pci-page mask from 4K to 8K BugID 4119734
-14 Fixes hex parsing of IP address BugID 4129194
1 Add the following lines to nvramrc if a serial console is used with OBP 3.5 P2.0.
Refer to BugIDs 4023405 and 4030675.
' false f0036644 f003a5e0 (patch
' false f0036650 f003a5e0 (patch
2 Checksum A2B2FAO. Not released. On Flash Update 1.8.
3 Checksum A2B2CA3. WO_12833 cancelled. Shipped by WO_12559.


Ultra 60 / E220R / Netra t 1120/1125

1M × 8 (Patch 106455)

Sun Ultra 60 Workstation Patch Readmes and Downloads
Sun Enterprise 220R Server Patch Readmes and Downloads
Sun Netra T1120 Server Patch Readmes and Downloads
Sun Netra T1125 Server Patch Readmes and Downloads

U2703 Flash PROM Revision
525-1701-01 P 1.0
525-1701-02 P 1.0B
525-1701-03 OBP 3.11 Version 15
525-1701-04 OBP 3.11 Version 18
525-1701-05 OBP 3.11 Version 18
525-1701-06 OBP 3.11 Version 19
525-1701-07 OBP 3.11 Version 24
525-1701-08 OBP 3.11 Version 25 + POST 1.0.8 1
525-1701-09 OBP 3.11 Version 26 + POST 2.0.0 + OBDIAG 1.3
525-1701-10 OBP 3.11 Version 27 3
525-1701-11 OBP 3.13 Version 1 + POST 2.0.1 + OBDIAG 1.3 2
525-1701-12 OBP 3.17 Version 0 + POST 2.0.2 + OBDIAG 1.3
525-1701-13 OBP 3.23 Version 1 + POST 2.0.2 + OBDIAG 1.3
106455-06 OBP 3.25 Version 0 + POST 2.0.2 + OBDIAG 1.3 (not ECO released)
106455-09 OBP 3.27 Version 0 + POST 2.0.3 + OBDIAG 1.3 (not ECO released)
525-1701-15 OBP 3.29 Version 0 + POST 2.0.3 + OBDIAG 1.3
106455-11 OBP 3.31 Version 0 + POST 2.0.3 + OBDIAG 1.3 (not ECO released)
Update 2.5 OBP 3.31 Version 0 + POST 2.0.3 + OBDIAG 1.3 (not ECO released)
1 Parts labeled 525-1701-08 with an arrow symbol are not write enabled.
    Trying to flash update a 525-1701-08 with an arrow symbol will fail.
2 Not ECO released. Not structured to the board. On Flash Update 1.10.
3 Not used. not ECO released. Not structured.

Ultra 60 PROM Changes
DASH DESCRIPTION
-09 Fixes Symbios SCSI controller booting BugID 4114784
-09 Adds 400:100, 440:110, 480:120, and 500:125 ÷4 modes
-09 Supports mixing 360MHz UltraSPARC mask# <80 and >=80
-09 Changed pci-page mask from 4K to 8K BugID 4119734
-09 Fixes hex parsing of IP address BugID 4129194
-10 Adds tape drive boot support
-12 Adds 450:112 ÷4 mode. Fix max memory hang during POST.
-13 Adds NVRAM variables for the Enterprise 220R
-15 Supports MAC address 00:03:BA:xx:xx:xx
-15 Supports Blaze UltraSPARC II


Ultra 80 / E420R / Netra t 1400/1405

1M × 8 (Patch 109082)

Sun Enterprise 420R Server Patch Readmes and Downloads
Sun Netra T1400 Server Server Patch Readmes and Downloads
Sun Netra T1405 Server Server Patch Readmes and Downloads

U3007 Flash PROM Revision
525-1780-06 OBP 3.23 Version 0 + POST 1.2.7 + OBDIAG 1.0
109082-01 OBP 3.25 Version 0 + POST 1.2.7 + OBDIAG 1.0 (not ECO released)
109082-02 OBP 3.27 Version 0 + POST 1.2.8 + OBDIAG 1.0 (not ECO released)
525-1780-09 OBP 3.29 Version 0 + POST 1.2.8 + OBDIAG 1.0 1 (109082-03/04)
109082-05 OBP 3.31 Version 0 + POST 1.2.8 + OBDIAG 1.0 (not ECO released) 3
525-1780-10 OBP 3.33 Version 0 + POST 1.2.10 + OBDIAG 1.0 2 (109082-06)
  1. Supports MAC address 00:03:BA:xx:xx:xx and Blaze UltraSPARC II.
  2. Adds support for Micron memory in the Netra t 1400/1405. (WO_27767)
  3. Not ECO released. Not structured to the board. Also available in Flash Update 2.5.


Enterprise 250

1M × 8 (Patch 106503)

Patch Readmes and Downloads

U2703 Boot Flash PROM Revision
525-1718-05 OBP 3.7 Version 1
525-1718-06 OBP 3.7 Version 2
525-1718-07 OBP 3.7 Version 3 + POST 6.0.2 + OBDIAG 3.17.1
525-1718-08 OBP 3.7 Version 7 + POST 6.0.4 + OBDIAG 3.19.1
525-1718-09 OBP 3.12 Version 10 + POST 6.0.8 + OBDIAG 4.5.1
525-1718-10 OBP 3.12 Version 11 + POST 6.0.8 + OBDIAG 4.5.1
525-1718-11 OBP 3.12 Version 12 + POST 6.0.8 + OBDIAG 4.5.1
525-1718-13 OBP 3.16 Version 1 + POST 6.0.9 + OBDIAG 4.5.1
525-1718-14 OBP 3.20 Version 0 + POST 6.1.0 + OBDIAG 4.5.1
525-1718-15 OBP 3.22 Version 0 + POST 6.1.0 + OBDIAG 4.5.1
Update 2.6 OBP 3.26 Version 0 + POST 6.1.0 + OBDIAG 4.5.1 (not ECO released)
106503-07 OBP 3.26 Version 0 + POST 6.1.0 + OBDIAG 4.5.1 (not ECO released)
106503-08 OBP 3.28 Version 0 + POST 6.1.0 + OBDIAG 4.5.1 (not ECO released)
106503-09 OBP 3.30 Version 0 + POST 6.1.0 + OBDIAG 4.5.1 (not ECO released)
U4401 Remote System Control Flash PROM Revision
525-1724-04 RSC main b0.22
525-1724-05 RSC main b0.22 m0.25
525-1724-06 RSC main b0.22 m0.28
525-1724-07 RSC main b1.1 m1.12 (not released)
525-1724-08 RSC main b1.3 m1.14

Enterprise 250 Boot PROM Changes
DASH DESCRIPTION
-09 Adds 400MHz support - Not used
-10 Adds 400MHz support
-11 Fixes SCMP timing problem with 400MHz BugID 4212155
-13 Adds 501-5440 support. Adds 5:1 clock ratio support.
-14 Adds Blaze module and DHCP boot support.
-14 Enables UE/CE Error checking on slave processors.
-15 Supports MAC address 00:03:BA:xx:xx:xx
2.6 4644899, 4472109, 4191694, 4213915, 4621868, 4109428, 4155723, and 4114057

Enterprise 250 RSC PROM Changes
DASH DESCRIPTION
-08 Required if System Board has 64MB DRAM at U4405
The 501-4681-09 and 501-5440-01 use 64MB DRAM.


Enterprise 450 / Ultra 450

1M × 8

Sun Enterprise 450 Server Patch Readmes and Downloads

U3101
U3101
501-2996 Flash PROM Revision (Patch 106122)
501-5028 Flash PROM Revision (Patch 106122)
525-1672-01 Pre-FCS
525-1672-02 Pre-FCS
525-1672-03 Pre-FCS
525-1672-04 P1.4
525-1672-05 P2 (525-1672-05, 525-1672-06, and 525-1672-07)
525-1672-06 P2
525-1672-07 P2
525-1672-08 OBP 3.5 Version 105 + POST 4.0.6
525-1672-09 Not used
525-1672-10 OBP 3.7 Version 107 + POST 5.0.8 + OBDIAG 3.9.2
Required for Solaris 7 64-Bit Operating System

Enterprise 450 - 1M × 8 (Patch 106122)

Sun Enterprise 450 Server Patch Readmes and Downloads

U3101 501-5270 Flash PROM Revision
525-1776-01 OBP 3.12 Version 1 + POST 6.0.6 + OBDIAG
525-1776-02 OBP 3.12 Version 2 + POST + OBDIAG
525-1776-03 OBP 3.12 Version 3 + POST + OBDIAG
525-1776-04 OBP 3.14 Version 1 + POST 6.0.9 + OBDIAG 4.4.1
525-1776-05 OBP 3.16 Version 2 + POST 6.0.9 + OBDIAG 4.4.1

Enterprise 450 - 1M × 8

Sun Enterprise 450 Server Patch Readmes and Downloads

U3101
U3101
501-5672 Flash PROM Revision (Patch 106122)
501-5673 Flash PROM Revision (Patch 106122)
525-1776-05 OBP 3.16 Version 2 + POST 6.0.9 + OBDIAG 4.4.1
525-1776-06 OBP 3.18 Version 0 + POST 6.1.0 + OBDIAG 4.4.1
525-1776-07 OBP 3.20 Version 0 + POST 6.1.0 + OBDIAG 4.5.1
525-1776-08 OBP 3.22 Version 0 + POST 6.1.0 + OBDIAG 4.5.1
Update 2.6 OBP 3.26 Version 0 + POST 6.1.0 + OBDIAG 4.5.1 (not ECO released)
106122-10 OBP 3.26 Version 0 + POST 6.1.0 + OBDIAG 4.5.1 (not ECO released)
106122-11 OBP 3.30 Version 0 + POST 6.1.0 + OBDIAG 4.5.1 (not ECO released)

525-1776 PROM Changes
DASH DESCRIPTION
-03 Fixes CPU2 timeout error during POST BugID 4195116
-05 Enable slave CPU error reporting BugID 4302752
-06 Adds support for 480MHz UltraSPARC II
-07 Adds DHCP boot support and Blaze UltraSPARC II support
-08 Supports MAC address 00:03:BA:xx:xx:xx
2.6 4644899, 4472109, 4191694, 4213915, 4621868, 4109428, 4155723, and 4114057


E3000/4000/5000/6000 / E3500/4500/5500/6500

CPU/Memory Board - 512K × 8 (Patch 103346)

Sun Enterprise 3500 Server Patch Readmes and Downloads
Sun Enterprise 4500 Server Patch Readmes and Downloads
Sun Enterprise 5500 Server Patch Readmes and Downloads
Sun Enterprise 6500 Server Patch Readmes and Downloads

U2501 Boot PROM Revision
525-1387-01 Pre-fcs
525-1387-02 Pre-fcs
525-1387-03 Not released
525-1387-04 Released by ECO (WO_09136)
525-1387-05 OBP 3.2 Version 4 + POST 3.2.2 (FCS release)
525-1387-06 OBP 3.2 Version 5 + POST 3.2.3
525-1387-07 OBP 3.2 Version 6 + POST 3.4.1
525-1387-08 OBP 3.2 Version 7 + POST 3.5.1
525-1387-09 OBP 3.2 Version 8 + POST 3.6.1
525-1387-10 OBP 3.2 Version 9 + POST 3.6.1
525-1387-11 OBP 3.2 Version 10 + POST 3.7.2
525-1387-12 OBP 3.2 Version 11 + POST 3.7.3
525-1387-13 OBP 3.2 Version 12 + POST 3.8.4 (first release for Ex500)
525-1387-14 OBP 3.2 Version 13 + POST 3.9.2 (ecr 12877 cancelled)
525-1387-15 OBP 3.2 Version 14 + POST 3.9.2
525-1387-16 OBP 3.2 Version 15 + POST 3.9.3
525-1387-17 OBP 3.2 Version 16 + POST 3.9.4
525-1387-18 OBP 3.2 Version 17 + POST 3.9.6 (WO_13965 cancelled)
525-1387-19 OBP 3.2 Version 18 + POST 3.9.4
525-1387-20 OBP 3.2 Version 19 + POST 3.9.8
525-1387-21 OBP 3.2 Version 21 + POST 3.9.10
not ECO released OBP 3.2 Version 22 + POST 3.9.22 (Patch 103346-22)
525-1387-22 OBP 3.2 Version 23 + POST 3.9.23
525-1387-23 OBP 3.2 Version 24 + POST 3.9.24
525-1387-24 OBP 3.2 Version 25 + POST 3.9.25 (WO_17418 cancelled)
525-1387-25 OBP 3.2 Version 26 + POST 3.9.26
525-1387-26 OBP 3.2 Version 27 + POST 3.9.27
525-1387-27 OBP 3.2 Version 28 + POST 3.9.28
525-1387-28 OBP 3.2 Version 29 + POST 3.9.29 (Patch 103346-29)
not ECO released OBP 3.2 Version 30 + POST 3.9.30 (Patch 103346-30)

E3000/4000/5000/6000 E3500/4500/5500/6500
CPU/Memory Board PROM Changes

DASH DESCRIPTION
-07 Adds 250MHz UltraSPARC support
Adds 256MB SIMMs support
Sets UltraSPARC I to run at 168MHz
Deconfigures Modules not compatible with master system board
POST runs checksum on plug-in card FCode
-08 Adds 250MHz UltraSPARC with 4MB Cache
Adds SOC+ I/O and I/O Graphics Cards support
-09 Adds PCI I/O Board support
-10 Adds FFB2 support
-11 Adds SOC AL WorldWideNumber support
-12 Fixes BugIDs 4018294, 4045138, 4086435, and 4092765.
Older versions are compatible with AMD AM29F040 but are
not compatible with SGS Thompson AM29F040
-13 Adds support for 300MHz - 400MHz UltraSPARC, 100MHz
Clock and System boards, and 90-100MHz Centerplanes
-14
-15
Fixes BugID 4116452 where a DIMM failure detected during
POST prevents booting with versions 3.7.2, 3.7.3, and 3.8.4.
Adds FC-AL disk display capability to OBP probe-scsi-all.
Oldest OBP supported in systems with 83 and 100mhz boards.
Oldest OBP supported in E3500-E6500.
-16 Fixes BugIDs 4105947, 4120409, 4126710, and 4123660.
Adds CPU DR support. Introduces BugID 4131463 where
POST fails connecting to a slot lower than first CPU board.
-17 Fixes OBP BugID 4115981 and POST BugID 4132713.
Required for Solaris 7 64-bit operating system.
-18 Fixes OBP BugID 4166670 where 400MHz module comes up at 200MHz.
Fixes POST BugID 4131463. Required for 400MHz 4MB Cache.
Release ECO WO_13965 was cancelled.
-19 Fixes OBP BugID 4166670 where 400MHz module comes up at 200MHz.
Required for 400MHz.
-21 Fixes .speed OBP command BugID 4168353.
Supports 5:1 clock board. Required for 400MHz 8MB Cache.
None Patch 103346-22 fixes mixed cache module BugID 4224994.
-22 Adds 256MB DIMM support.
-23 Fixes BugIDs 4276401, 4276722, and 4298992.
-25 Fixes 2GB memory bank BugID 4323635.
-27 Supports MAC address 00:03:BA:xx:xx:xx
-29 Required for 464MHz. Recommended for MSRAM modules BugID 4427581.
v30 Fixes BugID 4546501.


Sun Blade 100

1M × 8 (Patch 111179 or 119235 or 119238)
U40 Flash PROM Revision
370-4116-01 OBP 4.0 Version 31
370-4116-02 OBP 4.0 Version 34
370-4116-03 OBP 4.0 Version 37
111179-01 OBP 4.0 Version 4 + POST 1.2.6
370-4116-04 OBP 4.0 Version 41 (MAC address 00:03:BA support)
370-4116-05 OBP 4.0 Version 45 + POST 1.2.6
None OBP 4.2 Version 0 (19" flat-screen 365-1403 jitter fix
and improved flat panel monitor programming)
111179-02 OBP 4.2 Version 2 + POST 1.2.6 (-06 was not released)
370-4116-07 OBP 4.3 Version 2 + POST 1.2.6
111179-03 OBP 4.5 Version 0 + POST 2.0.1
370-4116-09 OBP 4.5 Version 9 + POST 2.0.1 (-08 was not released)
111179-05 OBP 4.6 Version 5 100/150 + POST 2.0.1 (not ECO released)
111179-06 OBP 4.6 Version 9 100/150 + POST 2.0.1 (not ECO released)
111179-07 OBP 4.10 Version 3 + POST 2.0.1 (not ECO released)
111179-08 OBP 4.10 Version 6 + POST 2.0.1 (not ECO released)
111179-09 OBP 4.13 Version 4 + POST 2.0.1 (not ECO released)
111179-10 OBP 4.16 Version 2 + POST 2.0.1 (not ECO released)
119238-01 OBP 4.15 Version 7 + POST 2.0.1 (not ECO released)
119235-01 OBP 4.17 Version 1 + POST 2.0.1 (not ECO released)


Sun Blade 150

1M × 8 (Patch >= 111179-05 or 119235 or 119238)
375-3088

Patch Readmes and Downloads

U40 Flash PROM Revision
370-5209-01 OBP 4.6 Version 7
370-5209-02 OBP 4.6 Version 5 + POST 2.0.1 (111179-05)
370-5209-03 OBP 4.6 Version 9 + POST 2.0.1 (111179-06) (BugID 4776410)
111179-07 OBP 4.10 Version 3 + POST 2.0.1 (not ECO released)
111179-08 OBP 4.10 Version 6 + POST 2.0.1 (not ECO released)
111179-09 OBP 4.13 Version 4 + POST 2.0.1 (not ECO released)
111179-10 OBP 4.16 Version 2 + POST 2.0.1 (not ECO released)
119238-01 OBP 4.15 Version 7 + POST 2.0.1 (not ECO released)
119235-01 OBP 4.17 Version 1 + POST 2.0.1 (not ECO released)

Sun Blade 150 - 1M × 8 (Patch >= 111179-05 or 119235 or 119238)
375-3152

Patch Readmes and Downloads

U40 Flash PROM Revision
370-6070-02 OBP 4.10 Version 6 + POST 2.0.1
111179-09 OBP 4.13 Version 4 + POST 2.0.1 (not ECO released)
111179-10 OBP 4.16 Version 2 + POST 2.0.1 (not ECO released)
119238-01 OBP 4.15 Version 7 + POST 2.0.1 (not ECO released)
119235-01 OBP 4.17 Version 1 + POST 2.0.1 (not ECO released)


Sun Fire V100

Patch Readmes and Downloads

258-7883-19 OBP 4.0 Version 14 Binary Code for 500MHz (111952-02)
259-3963-04 * OBP 4.0 Version 18 Binary Code for 550/650MHz (111952-03)
258-7871-17 LOMLITE2 3.11 Binary Code (110208-14)
258-7871-18 LOMLITE2 3.12 Binary Code (110208-15)
110208-18 LOMLITE2 3.13 Binary Code
110208-19 LOMLITE2 3.14 Binary Code
110208-20 LOMLITE2 3.14 Binary Code
110208-21 LOMLITE2 3.14 Binary Code
110208-22 LOMLITE2 3.14 Binary Code
254-0029-09 LOM EEPROM Version 1.4 Binary Code
254-0029-10 LOM EEPROM Version 1.5 Binary Code
* Do Not install Patch 111952-02 on Sun Fire V100 with 550/650MHz CPU.


Netra 120 / Sun Fire V120

(Patch 111991)

Sun Netra 120 Server Patch Readmes and Downloads

258-7887-20 OBP 4.0 Version 12 Binary Code
111991-04 OBP 4.0 Version 14 (not ECO released)
111991-05 OBP 4.0 Version 15 (not ECO released)
111991-06 OBP 4.0 Version 16 (not ECO released)
111991-07 OBP 4.0 Version 17 (not ECO released)
258-7887-21 OBP 4.0 Version 17 Binary Code
258-7871-17 LOMLITE2 3.11 Binary Code
258-7871-18 LOMLITE2 3.12 Binary Code
110208-18 LOMLITE2 3.13 Binary Cod
110208-19 LOMLITE2 3.14 Binary Cod
110208-20 LOMLITE2 3.14 Binary Cod
110208-21 LOMLITE2 3.14 Binary Cod
110208-22 LOMLITE2 3.14 Binary Cod
254-0031-07 LOM Version 1.2 EEPROM Binary Code
254-0031-08 LOM Version 1.3 EEPROM Binary Code


Netra t1 Model 100 / Netra t1 Model 105

1M × 8 (Patch 108673)

Sun Netra t1 model 100 Server Patch Readmes and Downloads
Sun Netra t1 model 105 Server Patch Readmes and Downloads

U1403* Flash PROM Revision
525-1768-11 OBP 3.10 Version 24
108673-01 OBP 3.10 Version 25 (not ECO released)
525-1768-13 OBP 3.10 Version 27 (Patch 108673-02) (SDRAM memory support)
525-1768-14 OBP 3.10 Version 30 (EDO + SDRAM memory support)
Added in March 2000 (WO_19934) . Removed in June 2001 (WO_20890) .
* This OBP is not the same as the Netra ct 400/800 or CP1500.


Netra T1 AC200 / Netra T1 DC200

258-7887-10 OBP 4.0 Version 1 Binary Code
258-7887-11 OBP 4.0 Version 3 Binary Code
258-7887-12 OBP 4.0 Version 4 Binary Code
258-7887-20 OBP 4.0 Version 12 Binary Code (Patch 111991-02)
111991-04 OBP 4.0 Version 14 (not ECO released)
111991-05 OBP 4.0 Version 15 (not ECO released)
111991-06 OBP 4.0 Version 16 (not ECO released)
111991-07 OBP 4.0 Version 17 (not ECO released)
258-7871-12 LOMLITE2 3.6 Binary Code
258-7871-13 LOMLITE2 3.7 Binary Code
258-7871-14 LOMLITE2 3.8 Binary Code (Patch 110208-08)
258-7871-16 LOMLITE2 3.10 Binary Code (Patch 110208-09)
258-7871-18 LOMLITE2 3.12 Binary Code (Patch 110208-15)
110208-18 LOMLITE2 3.13 Binary Code
110208-19 LOMLITE2 3.14 Binary Code
110208-20 LOMLITE2 3.14 Binary Code
110208-21 LOMLITE2 3.14 Binary Code
110208-22 LOMLITE2 3.14 Binary Code
258-7884-06 LOM Version 1.2 EEPROM Binary Code
258-7884-07 LOM Version 1.3 EEPROM Binary Code


Netra ct 400 / Netra ct 800

1M × 8

Sun Netra CT400 Server Patch Readmes and Downloads
Sun Netra CT800 Server Patch Readmes and Downloads

U1403* Flash PROM Revision
525-1849-04 OBP 3.14 Version 1 + POST 1.17
525-1849-05 OBP 3.14 Version 3 + POST 1.17
525-1849-06 OBP 3.14 Version 5 (SDRAM + MAC 00:03:BA support)
525-1849-07 OBP 3.14 Version 7 (Dual SCSI/Ethernet CPU LED fix)
* This OBP is not the same as the Netra t1 100/105 or CP1500.


Netra X1

Patch Readmes and Downloads

258-7883-10 OBP 4.0 Version 5 Binary Code
258-7883-11 OBP 4.0 Version 6 Binary Code
258-7883-14 OBP 4.0 Version 9 Binary Code
258-7883-19 OBP 4.0 Version 14 Binary Code (111952-02)
111952-03 OBP 4.0 Version 18 Binary Code
258-7871-14 LOMLITE2 3.8 Binary Code (110208-08)
258-7871-16 LOMLITE2 3.10 Binary Code (110208-09)
258-7871-18 LOMLITE2 3.12 Binary Code (110208-15)
110208-18 LOMLITE2 3.13 Binary Code
110208-19 LOMLITE2 3.14 Binary Code
258-7893-08 LOM EEPROM Version 1.3 Binary Code
258-7893-09 LOM EEPROM Version 1.4 Binary Code
258-7893-10 LOM EEPROM Version 1.5 Binary Code


  Copyright � 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback