Document Audience: | INTERNAL |
Document ID: | I0560-1 |
Title: | Webpage created detailing known problems with Dynamic |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | 2000-02-11 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by SunService)
FIN #: I0560-1
Synopsis: Webpage created detailing known problems with DynamicCreate Date: Feb/11/00
Keywords:
Webpage created detailing known problems with Dynamic
Top FIN/FCO Report: Yes
Products Reference: Enterprise 10000 Dynamic Reconfiguration fixes
Product Category: Server / SW Admin;
Product Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
Systems Affected
----------------
- UE10000 All Ultra Enterprise 10000 -
X-Options Affected
------------------
- - - - -
Parts Affected:
Part Number Description Model
----------- ----------- -----
- - -
References:
URL: http://hes.west/dhpg/#dr
Issue Description:
Due to various bugs discovered with Dynamic Reconfiguration affecting
the Enterprise 10000 Server, a website has been created to list both
problem and resolution of the bugs encountered. At this point, most
bugs have been resolved with fixes in the latest Kernel Update patch
but there are a few still outstanding which could potentially impact
production.
http://hes.west/dhpg/#dr
A website was chosen to ensure information is current and to address
the Dynamic Reconfiguration related issues in 2.5.1 and 2.6 OS
releases. The site will be updated as bugs are fixed and/or any new
bugs found.
As with any feature, customers are encouraged to test Dynamic
Reconfiguration prior to implementing it in a production environment.
Consideration should be given to efficiency of the kernel when Dynamic
Reconfiguration is enabled as well as the Dynamic Reconfiguration
operation itself. Enabling Dynamic Reconfiguration may have
performance implications and depending on Kernel Update may impact
stability.
In addition, there are inherent risks to introducing new Kernel Update
patches and these should be tested in conjunction with Dynamic
Reconfiguration in a non-production environment whenever possible. It
is essential to test Dynamic Reconfiguration under a representative
workload and comparable configuration in order to qualify successful
Dynamic Reconfiguration operations. This should include all third
party applications and drivers. Consult the Dynamic Reconfiguration
Users Guide for more details on proper configurations.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| X | REACTIVE (As Required)
---
Corrective Action:
This FIN serves as INFORMATION ONLY. On the web site referenced above,
a corrective action is listed for each bug identified. If a patch is
not available for a problem experienced, the appropriate workaround
should be exercised until such time that the patch is available and
can be installed.
Comments:
--------------------------------------------------------------------------
Implementation Footnote:
i) In case of MANDATORY FINs, Enterprise Services will attempt to
contact all affected customers to recommend implementation of
the FIN.
ii) For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical
support teams will recommend implementation of the FIN (to their
respective accounts), at the convenience of the customer.
iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the
need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
--------------
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/
* From there, select the appropriate link to browse the FIN or FCO index.
Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.corp/.
* From there, follow the hyperlink path of "Enterprise Services Documenta-
tion" and click on "FIN & FCO attachments", then choose the appropriate
folder, FIN or FCO. This will display supporting directories/files for
FINs or FCOs.
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to [email protected]
---------------------------------------------------------------------------