Document Audience:INTERNAL
Document ID:I0554-1
Title:Support of hubs with A5x00 and Veritas Volume Manager version
Copyright Notice:Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved
Update Date:2000-02-18

---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                            FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)
FIN #: I0554-1
Synopsis: Support of hubs with A5x00 and Veritas Volume Manager version
Create Date: Feb/18/00
Keywords: 

Support of hubs with A5x00 and Veritas Volume Manager version

Top FIN/FCO Report: No
Products Reference: A5x00 and Veritas Volume Manager 3.0.2
Product Category: Software / Unbundled;  Storage / SW Admin
Product Affected: 
Mkt_ID   Platform   Model   Description   Serial Number
------   --------   -----   -----------   -------------

Systems Affected
----------------

Mkt_ID            Platform   Model   Description              Serial Number
------            --------   -----   -----------              -------------

   -               A14         -     Ultra Enterprise 2             -
   -               E450        -     Ultra Enterprise 450           -
   -               E3000       -     Ultra Enterprise 3000          -
   -               E3500       -     Ultra Enterprise 3500          -
   -               E4000       -     Ultra Enterprise 4000          -
   -               E4500       -     Ultra Enterprise 4500          -
   -               E5000       -     Ultra Enterprise 5000          -
   -               E5500       -     Ultra Enterprise 5500          -
   -               E6000       -     Ultra Enterprise 6000          -
   -               E6500       -     Ultra Enterprise 6500          -
   -               E10000      -     Ultra Enterprise 10000         -


X-Options Affected
------------------
SG-XARY510A-45G      A5000     -     1X5X9.1GB Drive TableTop            - 
SG-XARY510A-127G     A5000     -     1X14X9.1GB Drive TableTop           -
SG-XARY511A-127G     A5000     -     1X14X9.1GB Drives Exp Cabinet       - 
SG-XARY512A-127G     A5000     -     1X14X9.1GB Sys Cabinet              -
SG-XARY513A-254G     A5000     -     2X14X9.1GB Drive 72" Exp Rack       - 
SG-XARY513A-764G     A5000     -     4X14X9.1GB Drive 72" Exp Rack       - 
SG-XARY533A-1528G    A5000     -     6X14X18.2GB Drive 72" Exp Rack      -
SG-XARY533A-509G     A5000     -     2X14X18.2GB Drive 72" Exp Rack      -
SG-XARY530A-91G      A5000     -     1X14X18.2GB Drive                   -
SG-XARY530A-91G      A5000     -     1X5X18.2GB Drive                    -
SG-XARY531A-254G     A5000     -     1X14X18.2GB Drive  72" Exp Rack     -
SG-XARY532A-254G     A5000     -     1X14X18.2GB Drive  Sys Cabinet      -
SG-XARY523A-1200     A5000     -     6X22X9.1GB Drives  72" Exp Rack     -
SG-XARY523A-800A     A5000     -     4X22X9.1GB Drives  72" Exp Rack     -
SG-XARY523A-400G     A5000     -     2X22X9.1GB Drives  72" Exp Rack     -
SG-XARY520A-200G     A5000     -     1X22X9.1GB Drives                   -
SG-XARY520A-63G      A5000     -     1X7X9.1 GB Drives                   -
SG-XARY521A-200G     A5000     -     1X22X9.1GB Drives  72" Exp Rack     -
SG-XARY522A-200G     A5000     -     1X22X9.1GB Drives  72" Sys Cabinet  -
Parts Affected: 
Part Number   Description                                        Model
-----------   -----------                                        -----

798-2205-01   Veritas Volume Manager for Solaris Version 3.0.2     -
References: 
BugId: 4289060, 4288750, 4276324
DOC:   Veritas Volume Manager Hardware Application Note Release 3.0.2
Issue Description: 
There is confusion with regard to supporting the A5x00 products with hubs 
attached and the use of Volume Manager version 3.0.2.  This confusion came 
from the Veritas Volume Manager Hardware Application Note Release 3.0.2, 
which states on page 12...

  "Dynamic Multi Pathing (DMP) does not support hub-attached A5000, 
  A5100, and A5200 arrays at this time.  See your sales representatives 
  for details about DMP support plans for this configuration." 

If the above recommendation is not followed, then the system could encounter 
catastrophic results.

The purpose of this FIN is to clarify the support restrictions relating
to Volume Manager 3.0.2 and use of hubs with A5X00 product line.
Implementation: 
---
        |   |   MANDATORY (Fully Pro-Active)
         ---    
         
  
         ---
        |   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
         --- 
         
                                
         ---
        | X |   REACTIVE (As Required)
         ---
Corrective Action: 
The following recommendation is provided as a guideline for authorized
Enterprise Services Field Representatives and Enterprise Customers to
clarify and emphasize the support restrictions for A5X00 configurations
and VxVM release 3.0.2;
   
VxVM supports configurations with multiple A5x00 disk arrays,
only if each of them is connected directly to the host (whether
in single or multipathed fashion).

VxVM does not support configurations with multiple A5x00 disk arrays 
connected to the host through one or more hubs or in a daisy chained 
manner.  

In case a customer has daisy chained configuration, the recommendation
is to reconfigure to a direct connect to the host if daisy chained
configuration.  At such time as fix is available, devices can be
reconfigured back to daisy chain configuration with the use of hubs.
 
The above support restrictions regarding A5X00 and VxVM 3.0.2 release 
WILL be removed when Veritas releases VxVM Volume Manager version 3.0.4.
Comments: 
--------------------------------------------------------------------------
Implementation Footnote: 
i)   In case of MANDATORY FINs, Enterprise Services will attempt to    
     contact all affected customers to recommend implementation of 
     the FIN. 
   
ii)  For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical    
     support teams will recommend implementation of the FIN  (to their  
     respective accounts), at the convenience of the customer. 

iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the   
     need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access:
-------------- 
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
  accessed internally at the following URL: http://edist.corp/.
  
* From there, follow the hyperlink path of "Enterprise Services Documenta- 
  tion" and click on "FIN & FCO attachments", then choose the appropriate   
  folder, FIN or FCO.  This will display supporting directories/files for 
  FINs or FCOs.
   
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to [email protected]
---------------------------------------------------------------------------
Statusinactive