Document Audience: | INTERNAL |
Document ID: | I0527-1 |
Title: | Rebuilding an E10000 SSP boot disk or Upgrading the OS on a SSP. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | 1999-10-21 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by SunService)
FIN #: I0527-1
Synopsis: Rebuilding an E10000 SSP boot disk or Upgrading the OS on a SSP.Create Date: Oct/21/99
Keywords:
Rebuilding an E10000 SSP boot disk or Upgrading the OS on a SSP.
Top FIN/FCO Report: No
Products Reference: SSP disk partition
Product Category: Server / SW Admin ;
Product Affected:
Systems Affected
----------------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
E10000 E10000 - Ultra Enterprise 10000 -
SS5 SPARCstation5 - SPARCstation5 SSP -
A21 Ultra 5 - Ultra 5 SSP -
A26 E250 - Enterprise 250 SSP -
X-Options Affected
------------------
2750A - - E10000 SERVICE PROCESSOR -
2752A - - E10000 SERVICE PROCESSOR -
2751A - - E10000 SERVICE PROCESSOR -
2753A - - E10000 SERVICE PROCESSOR -
2754A - - E10000 SERVICE PROCESSOR -
Parts Affected:
Part Number Description Model
----------- ----------- -----
- - -
References:
MANUAL: 805-4651-10 Sun Enterprise 10000 System Hardware Installation
and De-Installation Guide
MANUAL: 805-0310-11 Sun Enterprise 10000 System Overview Manual
Issue Description:
On page 1 of chapter 2 in the Sun Enterprise 10000 System Overview Manual,
it states that the SSP is built from a SPARCstation 5 with 32 Mbytes of
RAM and a 1-Gbyte disk. However, the FCS'ed SS5 SSP (2750A) was shipped
with a 2.1-Gbyte disk.
Also, the Sun Enterprise 10000 System Hardware Installation and
De-Installation Guide shows the following disk partitioning table:
"Table 10-1 Disk Partition"
----------------------------------------------------
slice 0 / 745 Mbytes
slice 1 swap 256 Mbytes
----------------------------------------------------
The table shown above is based on a 1-Gbyte disk. However, the SS5 SSP
nor any other supported SSP, ever ship with a 1-Gbyte disk. Thus, if
the installer were to rebuild the SSP boot disk from this table, there
is a risk of the SSP running out of disk space. In addition, future
SSP software and OS upgrades would render the SSP "out of disk space"
because 1GB or more of disk space will go unused.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| X | REACTIVE (As Required)
---
Corrective Action:
Authorized Enterprise Field Service Representatives should follow the
recommendation shown below in order to avoid the above mentioned
problem in cases where the SSP boot disk is rebuilt.
NOTE: This corrective action applies to ALL supported systems supported
as an SSP. i.e., SPARCstation 5, Ultra 5 or the E250.
When rebuilding the OS on a SSP boot disk it is recommended to install
the "Full Distribution plus OEM Support". In the "Customize Disk:"
screen, setup the disk partitions for the root disk as shown below:
----------------------------------------------------
slice 0 / remainder of free
slice 1 swap 256 Mbytes
----------------------------------------------------
Comments:
The SPARCstation 5 SSP was last price listed in July 1998. It was re-
placed by the Ultra 5 on the September 1998 price list. Just recently,
the Enterprise 250 was announced as being available as an SSP.
Part Number 806-1502-05 Sun Enterprise 10000 SSP 3.2 Installation Guide
and Release Notes are expected to be released with the Sol 7 11/99
release, the above mentioned corrective action will be included.
--------------------------------------------------------------------------
Implementation Footnote:
i) In case of MANDATORY FINs, Enterprise Services will attempt to
contact all affected customers to recommend implementation of
the FIN.
ii) For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical
support teams will recommend implementation of the FIN (to their
respective accounts), at the convenience of the customer.
iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the
need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
--------------
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/
* From there, select the appropriate link to browse the FIN or FCO index.
Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.corp/.
* From there, follow the hyperlink path of "Enterprise Services Documenta-
tion" and click on "FIN & FCO attachments", then choose the appropriate
folder, FIN or FCO. This will display supporting directories/files for
FINs or FCOs.
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to [email protected]
---------------------------------------------------------------------------