Document Audience:INTERNAL
Document ID:I0515-1
Title:Early shipments of Netra t1 Servers may have been shipped with the second ethernet port disabled.
Copyright Notice:Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved
Update Date:1999-08-14

---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)
FIN #: I0515-1
Synopsis: Early shipments of Netra t1 Servers may have been shipped with the second ethernet port disabled.
Create Date: Aug/13/99
Keywords: 

Early shipments of Netra t1 Servers may have been shipped with the second ethernet port disabled.

Top FIN/FCO Report: No
Products Reference: Disabled Netra t1 second ethernet port
Product Category: Server / Other ; Networking / Ethernet;
Product Affected: 
Mkt_ID   		Platform   Model   Description   Serial Number
------   		--------   -----   -----------   -------------
	
Systems Affected
----------------

N06-UGB1-9S064AH1       Netra        -       ASSY,NETRA,T1,360AC    -                         

X-Options Affected
------------------

       -                -            -        -                     -

Part Number   Description            Model
-----------   -----------            -----
600-6468-01   ASSY,NETRA,T1,360AC     105
540-4317-01   ASSY,GEN,360,NODISK,FJ  105
References: 
N/A
Issue Description: 
By manufacturing default, the Sun Netra t1 Server OBP env parameter
pcib-probe-list was set to 1,2 which means that only devices 1 and 2 
on the bus are probed and enabled, thus, only the ebus and the first
ethernet device are enabled.  The second ethernet port device 3, be-
comes disabled by default.  

The above mentioned problem can be identified on a Sun Netra t1 Server
from the OK prompt, by typing 'show-devs', if the following error is
displayed:

          Unable to find `/pci@1f,0/pci@1,1/network@3,1'

The Netra t1 Server does not recognize the second ethernet device. 

During the manufacturing and testing process the pcib-probe-list is
set to 1,2,3 thus, the second ethernet device is enabled.  Then at
the end of the system test, a script performs a 'set-defaults' on
the obp parameters, which returns the second ethernet device to the
disabled state.  As a result, hme1 is not probed and the second ether-
net port is therefore not added to the device tree.

In response to the above mentioned problem, the Manufacturing test
process has been ammended to NOT 'set-defaults' with pcib-probe-list 
set to 1,2,3.  All subsequent shipments from Aug/11/99 will be cor-
rected.
Implementation: 
---
        |   |   MANDATORY (Fully Pro-Active)
         ---    
         
  
         ---
        |   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
         --- 
         
                                
         ---
        | X |   REACTIVE (As Required)
         ---
Corrective Action: 
Enterprise Customers and Enterprise Field Service Representatives that
receive early shipments of Sun Netra t1 Servers (with ship dates prior 
to Aug/11/99) may correct the above mentioned disabled second ethernet
device by following the recommendation as shown below:

	1. Log in as/su to root

	2. Type the following three lines:

	eeprom pcib-probe-list=1,2,3
	eeprom output-device=ttya
	eeprom input-device=ttya

	3. Reboot
Comments: 
--------------------------------------------------------------------------
Implementation Footnote: 
i)   In case of MANDATORY FINs, Enterprise Services will attempt to    
     contact all affected customers to recommend implementation of 
     the FIN. 
   
ii)  For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical    
     support teams will recommend implementation of the FIN  (to their  
     respective accounts), at the convenience of the customer. 

iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the   
     need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access:
-------------- 
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
  accessed internally at the following URL: http://edist.corp/.
  
* From there, follow the hyperlink path of "Enterprise Services Documenta- 
  tion" and click on "FIN & FCO attachments", then choose the appropriate   
  folder, FIN or FCO.  This will display supporting directories/files for 
  FINs or FCOs.
   
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to [email protected]
---------------------------------------------------------------------------
Statusinactive