WARNING:Articles moved into the Archived collection were accurate at the "Last Update" date, but are not maintained from that date forward.
As such, Sun disclaims all implied or express warranties with respect to the information contained in such articles.
Document Audience:INTERNAL Archive
Document ID:I0502-1
Title:Visual identification of -02 and -03 GBICs without physically removing from system.
Copyright Notice:Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved
Last Updated Date:1999-06-18

---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)
FIN #: I0502-1
Synopsis: Visual identification of -02 and -03 GBICs without physically removing from system.
Create Date: Jun/17/99
Keywords: 

Visual identification of -02 and -03 GBICs without physically removing from system.

Top FIN/FCO Report: Yes
Products Reference: -02 and -03 GBIC Identification
Product Category: Storage / A5000
Product Affected: 
Mkt_ID   Platform   Model    Description   Serial Number
------   --------   -----    -----------   -------------
Systems Affected
----------------

  -       A14          -       Ultra Enterprise 2        -
  -       E450         -       Ultra Enterprise 450      -
  -       E3000        -       Ultra Enterprise 3000     -
  -       E3500        -       Ultra Enterprise 3500     -
  -       E4000        -       Ultra Enterprise 4000     -
  -       E4500        -       Ultra Enterprise 4500     -
  -       E5000        -       Ultra Enterprise 5000     -
  -       E5500        -       Ultra Enterprise 5500     -
  -       E6000        -       Ultra Enterprise 6000     -
  -       E6500        -       Ultra Enterprise 6500     -
  -       E10000       -       Ultra Enterprise 10000    -            

X-Options Affected
------------------  
Sun StorEdge A5000 14-Drive FC-AL Arrays
  
SG-XARY513A-764G   A5000    -    A5000, 764GB 84 Drive 72" Exp Rack  -
SG-XARY012A-509G   A5000    -    A5000, 509GB 56 Drive 56" Exp Rack  -
SG-XARY012A-254G   A5000    -    A5000, 254GB 28 Drive 56" Exp Rack  -
SG-XARY513A-254G   A5000    -    A5000, 254GB 28 Drive 72" Exp Rack  -
SG-XARY010A-45G    A5000    -    A5000, 45GB 5 Drive TableTop        -
SG-XARY510A-45G    A5000    -    A5000, 45GB 5 Drive TableTop        -
SG-XARY010A-127G   A5000    -    A5000, 127GB  14 Drive TableTop     -
SG-XARY510A-127G   A5000    -    A5000, 127GB  14 Drive TableTop     -
SG-XARY011A-127G   A5000    -    A5000, 127GB  14 Drive Rackmount    -
SG-XARY511A-127G   A5000    -    A5000, 127GB  14 Drive Rackmount    -
SG-XARY512A-127G   A5000    -    A5000, 127GB  14 Drive Rackmount    -
X2652A             E3500    -    FC-AL Interface Board               -
X6731A              -       -    FC-AL GBIC Module 100MB/s           -


  
Sun StorEdge A5100 14-Drive FC-AL Arrays  
  
SG-XARY533A-509G   A5100    -    A5100, 509GB  84 Drive 72" Exp Rack  -
SG-XARY533A-1019G  A5100    -    A5100, 1019GB 56 Drive 72" Exp Rack  -
SG-XARY533A-1528G  A5100    -    A5100, 1528GB 28 Drive 72" Exp Rack  -
SG-XARY531A-254G   A5100    -    A5100, 254GB 14 Drive 72" Rack Mnt, no skins -
SG-XARY532A-254G   A5100    -    A5100, 254GB 14 Drive 56/68" Rack Mnt,no skins-
SG-XARY530A-91G    A5100    -    A5100, 91GB  5 Drive TableTop        -
SG-XARY530A-254G   A5100    -    A5100, 254GB 5 Drive TableTop        -

Sun StorEdge A5200 22-Drive FC-AL Arrays
  
SG-XARY523A-1200G  A5200    -    A5200, 1200GB Exp Rack  -
SG-XARY523A-800G   A5200    -    A5200,  800GB Exp Rack  -
SG-XARY523A-400G   A5200    -    A5200,  400GB Exp Rack  -
SG-XARY520A-200G   A5200    -    A5200,  200GB TableTop  -
SG-XARY521A-200G   A5200    -    A5200,  200GB Rackmount for StorEDGE cab   -
SG-XARY522A-200G   A5200    -    A5200,  200GB Rackmount for Enterprise Sys -
SG-XARY520A-63G    A5200    -    A5200,  127GB TableTop  -
Parts Affected: 
Part Number   Description                 Model
-----------   -----------                 -----
370-2303-02   OE Module, GBIC, TRIDENT      - 
370-3975-01   OE Module, GBIC, TRIDENT IBM  -
370-2303-03   OE Module, GBIC, TRIDENT      -
References: 
FCO: A0144-2
URL: http://storageweb.eng/techmark_site/aces/aces.list.html
URL: http://storageweb.eng/techmark_site/tiger/index.html
Issue Description: 
INFORMATIONAL ONLY 


The Factory phased in shipments of -03 GBICS beginning early April 1999.
A5X00s with chassis s/n greater than 9917 will have the -03 GBIC, or an 
IBM -02 CD GBIC.  These modules appear physically identical to the -02 
modules.  Field personnel cannot differentiate between module revisions 
without physically removing them to read the revision level on the connector 
label.  This would require an unacceptable maintenance downtime for host 
systems.

FCO A0144-2 provides for proactive replacement of Vixel GBICs revision -02 and
below to address an early wear out of the laser component observed on some 
parts in their second year of operation.  The Vixel -03 GBIC incorporates
a new, longer life laser technology.  The -03 GBICs are reliable and 
acceptable for use.  All IBM GBIC revisions have proven reliable in the field.

This FIN documents field identification of Vixel -03 GBICs.

The Vixel -03 Vertical cavity GBICS can be identified as follows:

	Parts are marked as a -03; this marking can be found on the
	GBIC connector (system interface connector) as "03a" for
	-03 revision a.
	
	The inside if the cable connector housing will be silver
	in color on the Vixel vertical cavity (-03) parts; black on
	the -02 cd lazer versions.
	
	ON A LIMITED QUANTITY ONLY (aprox 3-5K of aprox 20k shipped)
	of -03 vertical cavity vixel GBICS, the lettering on the 
	cable connector (visible from the outside of the system with 
	the cables installed) will be red or rust in color.
Implementation: 
---
        |   |   MANDATORY (Fully Pro-Active)
         ---    
         
  
         ---
        |   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
         --- 
         
                                
         ---
        | X |   REACTIVE (As Required)
         ---
Corrective Action: 
No action is required by Enterprise Services Support Reps or Enterprise
Customers.  This FIN serves as information only.
Comments: 
--------------------------------------------------------------------------
Implementation Footnote: 
i)   In case of MANDATORY FINs, Enterprise Services will attempt to    
     contact all affected customers to recommend implementation of 
     the FIN. 
   
ii)  For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical    
     support teams will recommend implementation of the FIN  (to their  
     respective accounts), at the convenience of the customer. 

iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the   
     need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access:
-------------- 
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
  accessed internally at the following URL: http://edist.corp/.
  
* From there, follow the hyperlink path of "Enterprise Services Documenta- 
  tion" and click on "FIN & FCO attachments", then choose the appropriate   
  folder, FIN or FCO.  This will display supporting directories/files for 
  FINs or FCOs.
   
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to [email protected]
---------------------------------------------------------------------------
Statusinactive