Document Audience: | INTERNAL
Archive
| WARNING:Articles moved into the Archived collection were accurate at the "Last Update" date, but are not maintained from that date forward.
As such, Sun disclaims all implied or express warranties with respect to the information contained in such articles.
Document ID: | I0464-1 |
Title: | A Power Patch is required to operate E10000 2761A System Boards. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Last Updated Date: | 2004-01-07 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by SunService)
FIN #: I0464-1
Synopsis: A Power Patch is required to operate E10000 2761A System Boards.Create Date: Dec/11/98
Keywords:
A Power Patch is required to operate E10000 2761A System Boards.
Top FIN/FCO Report: Yes
Products Reference: E10000 power patch
Product Category: Server / System Board
Product Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
Systems Affected
----------------
E10000 E10000 ALL Ultra Enterprise E10000 Server -
HPC10000 E10000 ALL Sun HPC 10000 Server -
X-Options Affected
------------------
E10000-SW-SSP-3.1 - - System Service Processor 3.1 -
E10000-SW-SSP-3.0 - - System Service Processor 3.0 -
Parts Affected:
Part Number Description Model
----------- ----------- -----
501-4347-0X E10000 System Board -
501-4786-0X E10000 System Board -
501-4903-0X E10000 System Board -
501-5240-0X E10000 System Board -
501-5278-0X E10000 System Board -
501-5279-0X E10000 System Board -
References:
DOC: 805-7188-10 Sun Enterprise 10000 System Power Patch Note
PatchId: 106465-03 (or higher) for SSP 3.1
PatchId: 104846-11 (or higher) for SSP 3.0
Issue Description:
This FIN is intended to provide Important Information concerning
the Enterprise 10000 SSP Power Patch, the 2760A System Board and
the 2761A System Board.
CAUTION - Failure to install this patch will:
o Cause possible system component damage when using 2760A system
boards and processors that are unsupported by the 2760A system
board.
o Preclude the 2761A system board from powering on.
NOTE: The 2761A system board is a replacement for the 2760A system
board and will support future UltraSPARC II processors.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| X | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| | REACTIVE (As Required)
---
Corrective Action:
The installation of the following patches is MANDATORY for SSP
version 3.0 and SSP version 3.1.
1. If using SSP version 3.0 install:
Patch-ID# 104846-12
Keywords: Starfire bringup power DR board domain create remove
arbstop
Synopsis: SSP 3.0: bringup and power fixes
Date: Oct/13/98
Solaris Release: 2.5.1
SunOS release: 5.5.1
Unbundled Product: System Service Processor (SSP)
Unbundled Release: 3.0
Topic: SSP 3.0: power fixes
2. If using SSP version 3.1, install:
Patch-ID# 106465-03
Keywords: Starfire power 400MHz snmpd
Synopsis: SSP 3.1: power command fixes
Date: Oct/13/98
Solaris Release: 2.5.1
SunOS release: 5.5.1
Unbundled Product: System Service Processor (SSP)
Unbundled Release: 3.1
Topic: SSP 3.1: power command fixes
*Be sure to reference to the README file accompanying the patch for
installation instructions.
Comments:
*The revision of the patches (shown above) are subject to change. Refer
to the SunSolve database for the most current version.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of MANDATORY FINs, Enterprise Services will attempt to contact
all affected customers to recommend implementation of the FIN.
ii) For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical sup-
port teams will recommend implementation of the FIN (to their respective
accounts), at the convenience of the customer.
iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the need
arises.
-----------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
______________
* Access the top level URL of http://cte.corp/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
_______________________
* Access the SunSolve Online URL at http://sunsolve.Corp/
* From there, select the appropriate link to browse the FIN or FCO index.
Supporting Documents:
____________________
Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.corp/.
* From there, follow the hyperlink path of "SunService Documentation" and
click on "FIN & FCO attachments", then choose the appropriate folder,
FIN or FCO. This will display supporting directories/files for FINs or
FCOs.
Internet Access:
_______________
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
________
Send questions or comments to [email protected]
---------------------------------------------------------------------------