WARNING:Articles moved into the Archived collection were accurate at the "Last Update" date, but are not maintained from that date forward.
As such, Sun disclaims all implied or express warranties with respect to the information contained in such articles.
Document Audience:INTERNAL Archive
Document ID:I0331-2
Title:UPDATED FIN. E10000 Domain unbootable if the value for dr-max-mem is set too large.)
Copyright Notice:Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved
Last Updated Date:2004-01-07

---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)
FIN #: I0331-2
Synopsis: UPDATED FIN. E10000 Domain unbootable if the value for dr-max-mem is set too large.)
Create Date: Sep/28/99
Keywords: 

UPDATED FIN. E10000 Domain unbootable if the value for dr-max-mem is set too large.)

Product Category: Server / System CPU Firmware

PRODUCT_REFERENCE:  dr-max-mem
Product Affected: 
Mkt_ID    Platform   Model    Description               Serial Number
------    --------   -----    -----------               -------------
Systems Affected
------- ---------

  -       E10000     ALL      Ultra Enterprise 10000          -
 
 
X-Options Affected
------------------
Parts Affected: 
Part Number       Description          Model
-----------       -----------          -----
SSP Version 3.0
References: 
BugId: 4049092
Issue Description: 
From FIN# I0331-1
 
Depending on system configuration and the value for the system
parameter "dr-max-mem", a domain can become unbootable if OBP runs out
of its own memory and goes into UFSBOOT text/data space.  The result is
UFSBOOT crashes.  Typically, this occurs when the value for
"dr-max-mem" is 16 GB.


Below are two examples of the failure:

 -----
 <#0 ok boot -v disk
 Boot device: /sbus@41,0/QLGC,isp@0,10000/sd@0,0:a  File and args: -v
 disk
 Size: 307265+87152+474340 Bytes
 cpu0: SUNW,UltraSPARC (upaid 0 impl 0x11 ver 0x11 clock 250 MHz)
 cpu1: SUNW,UltraSPARC (upaid 1 impl 0x11 ver 0x11 clock 250 MHz)
 cpu2: SUNW,UltraSPARC (upaid 2 impl 0x11 ver 0x11 clock 250 MHz)
 cpu3: SUNW,UltraSPARC (upaid 3 impl 0x11 ver 0x11 clock 250 MHz)
  .
  .
  .
 cpu18: SUNW,UltraSPARC (upaid 18 impl 0x11 ver 0x11 clock 250 MHz)
 cpu19: SUNW,UltraSPARC (upaid 19 impl 0x11 ver 0x11 clock 250 MHz)
 DR: reserving 20960 pages for caged kernel
 SunOS Release 5.5.1 Version Generic [UNIX(R) System V Release 4.0]
 Copyright (c) 1983-1996, Sun Microsystems, Inc.
 Illegal instruction
 <#0 ok
 -----
 
 OR
 
 -----
 <#0 ok boot -v disk
 Boot device: /sbus@41,0/QLGC,isp@0,10000/sd@0,0:a  File and args: -v
 disk
 Size: 307265+87152+474340 Bytes
 cpu0: SUNW,UltraSPARC (upaid 0 impl 0x11 ver 0x11 clock 250 MHz)
 cpu1: SUNW,UltraSPARC (upaid 1 impl 0x11 ver 0x11 clock 250 MHz)
 cpu2: SUNW,UltraSPARC (upaid 2 impl 0x11 ver 0x11 clock 250 MHz)
 cpu3: SUNW,UltraSPARC (upaid 3 impl 0x11 ver 0x11 clock 250 MHz)
  .
  .
  .
 cpu10: SUNW,UltraSPARC (upaid 10 impl 0x11 ver 0x11 clock 250 MHz)
 cpu11: SUNW,UltraSPARC (upaid 11 impl 0x11 ver 0x11 clock 250 MHz)
 DR: reserving 20960 pages for caged kernel
 SunOS Release 5.5.1 Version Generic [UNIX(R) System V Release 4.0]
 Copyright (c) 1983-1996, Sun Microsystems, Inc.
 Fast Data Access MMU Miss
 <#0 ok
 ------


IMPLEMENTATION: 
 
         ---
    	|   |  	MANDATORY (Fully Pro-Active)
  	 ---    
  	 
  
         ---
    	|   | 	CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
  	 --- 
  	 
  	   			
         ---
    	| X | 	REACTIVE (As Required)
  	 ---
Corrective Action: 
*Addition for FIN# I0505-2;
 
Install Patch-ID# 104853-02 or higher on the SSP associated with
the E10K domain, making sure to follow the installation instructions 
associated with the patch.  If SSP is version 3.1 or higher, this 
patch does not apply.
Comments: 
--------------------------------------------------------------------------
Implementation Footnote:

i)   In case of MANDATORY FINs, Enterprise Services will attempt to    
     contact all affected customers to recommend implementation of 
     the FIN. 
   
ii)  For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical    
     support teams will recommend implementation of the FIN  (to their  
     respective accounts), at the convenience of the customer. 

iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the   
     need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access:
-------------- 
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
  accessed internally at the following URL: http://edist.corp/.
  
* From there, follow the hyperlink path of "Enterprise Services Documenta- 
  tion" and click on "FIN & FCO attachments", then choose the appropriate   
  folder, FIN or FCO.  This will display supporting directories/files for 
  FINs or FCOs.
   
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to [email protected]
---------------------------------------------------------------------------
Statusinactive