Document Audience:INTERNAL
Document ID:A0235-1
Title:System fans issues on Netra t 1400/1405 (LW3) may result in "low fan speed" alarms or other system errors.
Copyright Notice:Copyright © 2007 Sun Microsystems, Inc. All Rights Reserved
Update Date:Wed Jun 30 00:00:00 MDT 2004

----------------------------------------------------------------------------

             - Sun Proprietary/Confidential: Internal Use Only -
----------------------------------------------------------------------------

                             FIELD CHANGE ORDER
            (For Authorized Distribution by Enterprise Services)
            
FCO #: A0235-1
Status: inactive
Synopsis: System fans issues on Netra t 1400/1405 (LW3) may result in "low fan speed" alarms or other system errors.
Date: June/30/2004
SunAlert: No
Top FIN/FCO Report: No
Products Reference: Netra t1400/1405 System Fans
Product Category: Server / System Component
Product Affected: 
Systems Affected:

Mkt_ID   Platform   Model    Description        
------   --------   -----    -----------        
-        N15        ALL      Netra t1400       
-        N14        ALL      Netra t1405        


X-Options Affected:

Mkt_ID      Platform    Model    Description       
------      --------    -----    -----------	
N/A
Parts Affected: 
Part Number	          Description             	     
-----------	          -----------	
370-3976-02 (or below)    System Fan Assembly
References: 
BugID: 4989154        
   Radiance:  10403815, 36511310, 36577516       
   LEAP: 2450  
   ECO:  WO_27578
Issue Description: 
Degraded Netra t1400/1405 system cooling could result in "low fan speed" alarms
and possible system errors.  A failing fan might result in alarms for either of
the two system cooling fans.  These fans are redundant so the loss of one fan
does not cause other issues.

Root cause has determined that the current fans may have shorter than expected
life due to heating of voltage regulator components in the fan motor.  The
voltage regulators protect themselves from over heating by reducing the current
delivered to the fan motor.  Continuous operation at their upper temperature
limit causes the voltage regulators to fail in a low current state.  This results
in the fan operating at a lower than acceptable speed.  The internal heating of
the regulators is highest at normal room temperatures when the fans are operating
at their lowest speed.

Manufacturing has qualified a second source for these fans and has dash rolled
the FRU/CRU part number to reflect this change.  Thes replacement fan uses
digital control of the motor drive to regulate speed.  This is more efficient
and eliminates the need for a voltage regulator.

Corrective action was made available by Sun manfacturing via ECO# WO_27578
released October 20, 2003.

Corrective action was made available by Sun Services via LEAP# 2450.A
released December 19, 2003.
Implementation: 
---
|   |   MANDATORY (Fully Pro-Active)
 ---

 ---
|   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
 ---

 ---
| X |   UPON FAILURE
 ---
Replacement Time Estimate: 
1 hour
Special Considerations: 
All TZ GEOs are ready to implement this FCO except for APAC and Japan.
APAC and Japan will be materially ready to support this FCO:

   APAC/Japan    End of August, 2004

This FCO authorizes the replacement of both system fans only when
one has failed.  Multiple issues with this fan at one customer site
should be escalated to ensure proper handling of customer situation.
Corrective Action: 
Upon failure replace BOTH system fans as follows:

   - replace 370-3976-02 (or less) with 370-3976-03 (or above)
Comments: 
Billing Type: 
Warranty: Sun will provide parts at no charge under Warranty
           Service. On-Site Labor Rates are based on how the
           system was initially installed.

 Contract: Sun will provide parts at no charge. On-Site Labor Rates
           are based on the type of service contract.

 Non Contract: Sun will provide parts at no charge. Installation by
               Sun is available based on the On-Site Labor Rates
               defined in the Price List.

--------------------------------------------------------------------------
Implementation Footnote: 
________________________

i)   In case of Mandatory FCOs, Sun Services will attempt to contact
      all known customers to recommend the part upgrade.

ii)  For controlled proactive swap FCOs, Sun Services mission critical
     support teams will initiate proactive swap efforts for their respective
     accounts, as required.

iii) For Replace upon Failure FCOs, Sun Services partners will implement
     the necessary corrective actions as and when they are required.

--------------------------------------------------------------------------

All released FINs and FCOs can be accessed using your favorite network
browser as follows:

SunSolve Internal Access:
_______________________

* Access the SunSolve Online URL at http://sunsolve.Central/

* From there, select the appropriate link to browse the FIN or FCO index.

Internet Access:
_______________

* Access the top level URL of  https://spe.sun.com

FIN/FCO Homepage Access:
_________________________

* Access the top level URL of http://sdpsweb.Central/FIN_FCO/index.html

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.

To submit either a FIN or FCO refer to the following URLs for templates
and instructions;

*  For FCO: http://pronto.central/fco.html
*  For FIN: http://pronto.central/fin.html

--------------------------------------------------------------------------
General:
________

Send questions or comments to [email protected]

---------------------------------------------------------------------------
Statusinactive