FIELD CHANGE ORDER
(For Authorized Distribution by Enterprise Services)
FCO #: A0216-1
Status: inactive
Synopsis: Rail stops on Sun Fire V210/V240 servers may fail when unit is pulled out for servicing.Date: Sep/18/2003
SunAlert: No
Top FIN/FCO Report: Yes
Products Reference: Sun Fire V210 / V240
Product Category: Server / System Component
Product Affected:
Systems Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- N31 ALL Sun Fire V210 -
- N32 ALL Sun Fire V240 -
X-Options Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
N/A
Parts Affected:
Part Number Description Model
----------- ----------- -----
370-5707-01 Rack Sliderail Kit -
(SCSI Devices)
Type Vendor Model SerialNumber(Min) SerialNumber(Max) Firmware
---- ------ ------- ----------------- ----------------- --------
N/A
References:
WWStopShip: P200-20154.A1
ECO: WO_27268
FCO: A0214-2
LEAP: 2349
Issue Description:
When sliding out a Sun Fire V210 or V240 the rail slide stops may not
function properly which could cause the system to fall off it's rails.
Sun Fire V210 and V240 systems that shipped between May 15, 2003 and
July 30, 2003 are impacted by this issue. Systems that shipped on or
after Aug 4, 2003 are not impacted by this issue.
This issue only affects V210/V240 systems that are slid out of the rack;
once the systems are slid into the rack they will remain in place.
The Rack slide stop mechanism spring retainer can fail with the result
that a system could be extended past the outer stop position without
having to operate the rackslide release lever. The design has been
modified and this problem was corrected at the supplier as of August 4,
2003.
In order to help identify customer shipments a Customer List is
available in StarOffice format via the below URL...
http://sdpsweb.central/FIN_FCO/FCO/FCO_A0214-1_Dir/A0214-1_15Aug.sxc
In addition, a Customer Letter has been developed and is available in
plain text via the below URL;
http://sdpsweb.central/FIN_FCO/FCO/FCO_A0216-1_Dir/Customer_Letter
Below is a matrix of Marketing part numbers to manufacturing part numbers to
affected FRU motherboard part numbers as shipped from Sun manufacturing.
SUN FIRE V210 (1U)
--------------
Marketing P/N Manufacturing P/N
----------------------------------------
N31-XUB1-9S-512AV1 602-2307-01
N31-XUB2-9S-204AV2 602-2394-01
N31-XUB1-512AV1-IP 602-2307-01
N31-XUB2-204AV2-IP 602-2394-01
N31-XUB1-9S-512ADE 602-2307-01
SUN FIRE V240 (2U)
-------------
Marketing P/N Manufacturing P/N
----------------------------------------
N32-XUB1-9S-512AV1 602-2396-01
N32-XUB2-9S-204AV2 602-2397-01
N32-XUB1-512AV1-IP 602-2396-01
N32-XUB2-204AV2-IP 602-2397-01
N32-XUB2-9S-204ADE 602-2397-01
The system serial number can be read as shown in the below example;
HN31540241
||||||||||
|||||\\\\\
||||| ----- unique serial number identifier
||\\\
|| ----- date code - 315 = year 2003, week 15
\\
----- HM = V210 / HN = V240
Corrective action was made available in manufacturing by dash rolling the
370-5707 rail kit from -01 to -02 via ECO# WO_27268 as of August 13, 2003.
Corrective action was made available in Sun Services by releasing the inner
rail kit (Sun p/n 370-6181-01) via ECO# WO_27268 as of August 13, 2003.
In addition, the MAL (minimal acceptable level) changed from -01 to -02
via LEAP 2349 which was released on August 21, 2003.
Parts Affected:
December 31, 2003
Implementation:
---
| X | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| | UPON FAILURE
---
Replacement Time Estimate:
0.25 hours
Special Considerations:
Plan on implementing this FCO at the same time as FCO A0214-2
in order to limit system downtime.
No onsite service should be provided for the Rail only FCO
implementation as rails are customer installable.
Corrective Action:
Replace the INNER SLIDERAILS in all Sun Fire V210/V240 systems,
identified in the Customer list above, with Sun p/n 370-6181-01.
Detailed Instructions for replacing the Inner Sliderails:
--------------------------------------------------------
1. Disconnect all cables from the rear of the system
2. Carefully slide out the system from the rack with caution in case
the rail stops are not working correctly
3. Place the system on a suitable work surface and remove the screws
securing the two INNER GLIDE rails from either side of the chassis. See
the "Sun Fire V210 and V240 Server Installation Guide (816-4825-11),
Chapter 2, pages 10,11 and 12 for a description and diagram of the rails.
4. Fit the replacement INNER GLIDE rails (F370-6181-01) to either side
of the chassis as described in the "Sun Fire V210 and V240 Server
Installation Guide (816-4825-11), Chapter 2, pages 10,11 and 12.
NOTE: It is not necessary to replace the other parts of the SLIDE
ASSEMBLY or the CABLE MANAGEMENT ARM. Only the INNER GLIDE rails need
to be replaced.
5. Slide the system back into the rack and reconnect all cables.
6. The Sun Fire V210/V240 should be marked using a permanent pen or
marker write "ECO# WO_27268" on the back of the sytstem.
7. The defective INNER GLIDE rails should be scrapped.
Comments:
Billing Type:
Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on how the
system was initially installed.
Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.
Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of Mandatory FCOs, Sun Services will attempt to contact
all known customers to recommend the part upgrade.
ii) For controlled proactive swap FCOs, Sun Services mission critical
support teams will initiate proactive swap efforts for their respective
accounts, as required.
iii) For Replace upon Failure FCOs, Sun Services partners will implement
the necessary corrective actions as and when they are required.
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
______________
* Access the top level URL of http://sdpsweb.Central/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
_______________________
* Access the SunSolve Online URL at http://sunsolve.Central/
* From there, select the appropriate link to browse the FIN or FCO index.
Internet Access:
_______________
* Access the top level URL of https://spe.sun.com
--------------------------------------------------------------------------
General:
________
Send questions or comments to [email protected]
---------------------------------------------------------------------------