Document Audience: | INTERNAL |
Document ID: | A0197-1 |
Title: | Ultra 10 Systems within an affected serial number range may not pass EMI. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | Fri Jun 28 00:00:00 MDT 2002 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD CHANGE ORDER
(For Authorized Distribution by SunService)
FCO #: A0197-1
Status: active
Synopsis: Ultra 10 Systems within an affected serial number range may not pass EMI.Date: June/28/2002
Keywords:
Ultra 10 Systems within an affected serial number range may not pass EMI
SunAlert: No
Top FIN/FCO Report: No
Products Reference: Ultra 10 / Cable Kit
Product Category: DeskTop / System Component
Product Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- A22 Ultra 10 - xx101xxxxx to xx214xxxxx
X-Options Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
References:
ECO : W0_23179
LEAP : 2009.A
BugID : 446866
ESC : 534635
Manual : 805-7764 Sun Ultra 10 Service Manual
Issue Description:
Ultra 10 Systems within the above affected serial number range,
and having either 400MHz or 440MHz CPU modules, may not pass
Electro Magnetic Interference (EMI). Only systems installed in
Medical Facilities, where strict EMI standards must be maintained
to avoid interference with other equipment, are impacted.
Root cause has been found to be excessive EMI from the 400MHz or 440MHz
CPU module clock generation circuitry. Emission variance between sample
modules were found to be quite high.
Corrective action was made available in Manufacturing via ECO W0_23179
on May 1, 2002 by releasing part number 370-4995-01. Corrective action
was made available in Enterprise Services via LEAP #2009.A on May 15,
2002.
Parts Affected:
June 28, 2003
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| X | UPON FAILURE
---
Replacement Time Estimate:
.5 hours
Corrective Action:
Upon Failure or customer need add EMI retrofit Cable Kit (P/N 370-4995-01).
Installation instructions included with Kit.
Comments:
Billing Type:
Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on how the
system was initially installed.
Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.
Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of Mandatory FCOs, Enterprise Services will attempt to contact
all known customers to recommend the part upgrade.
ii) For controlled proactive swap FCOs, Enterprise Services mission critical
support teams will initiate proactive swap efforts for their respective
accounts, as required.
iii) For Replace upon Failure FCOs, Enterprise Services partners will implement
the necessary corrective actions as and when they are required.
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
______________
* Access the top level URL of http://sdpsweb.EBay/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
_______________________
* Access the SunSolve Online URL at http://sunsolve.Central/
* From there, select the appropriate link to browse the FIN or FCO index.
Internet Access:
_______________
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
________
Send questions or comments to [email protected]
---------------------------------------------------------------------------