Document Audience:INTERNAL
Document ID:A0188-1
Title:The 3.3V DC-DC Converter on Sun Fire V880 CPU/Mem Boards may cause the system to shutdown and start reboot process around the failed CPU/Mem Board.
Copyright Notice:Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved
Update Date:Tue Feb 05 00:00:00 MST 2002

---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                               FIELD CHANGE ORDER
                  (For Authorized Distribution by SunService)

 
FCO #: A0188-1
Status: inactive
Synopsis: The 3.3V DC-DC Converter on Sun Fire V880 CPU/Mem Boards may cause the system to shutdown and start reboot process around the failed CPU/Mem Board.
Date: Feb/05/2002
Keywords: 

The 3.3V DC-DC Converter on Sun Fire V880 CPU/Mem Boards may cause the system to shutdown and start reboot process around the failed CPU/Mem Board.

SunAlert: Y
Top FIN/FCO Report: Yes
Products Reference: Sun Fire V880 CPU/Mem Board
Product Category: Server / System Component
Product Affected: 
Mkt_ID   Platform   Model     Description       Serial Number
------   --------   -----     -----------       -------------
Systems Affected:
------- --------
-         A30       ALL       Sun Fire V880      < 205xxxxxx

X-Options Affected
--------- -------
X7047A    A30        -        CPU/Mem Module         -
Parts Affected: 
Part Number              Description                  Model
-----------              -----------                  -----
501-5818-05(Or Less)     CPU/Mem Module V880            -
References: 
ECO: WO_23128        
 ECO: WO_23160        
 ECO: WO_23124        
 LEAP: 1906            
 LEAP: 1911 
 Sun Alert: 42977
Issue Description: 
On a Sun Fire V880 (Daktari), the 3.3V DC-DC Converter (located on the CPU/Mem
Board) can fail causing the system to shutdown and start a reboot process around
the failed CPU/Mem Board.  After the system reboots it will experience a
performance degradation due to the lost CPU/Mem Board.

Failed CPU/Mem Boards can be identified by inspecting the CPU Status Panel
located inside the right panel door.  A failed CPU/Mem Board would not have
the Green (power) light illuminated for that slot.

A root cause analysis has determined the problem to be related to a faulty
design of the 3.3V DC-DC Converter board FAB which is a socketed board on the
CPU/Mem Board.  The 1.5V DC-DC Converter is not affected.  Corrective action
has been taken in the form of a new board layout design which will eliminate
the quality issue as well as process improvements at the manufacturer.

All SunFire V880 systems were placed on StopShip as of January 29th, 2002.
Good systems began shipping as of February 8, 2002.

Corrective Action was made available in Worldwide Operations by dash rolling the
3.3V DC-DC Converter from 300-1437-03 to 300-1437-04 via ECO# WO_23124 on
January 13, 2002, and by dash rolling the CPU Module from 501-5818-05 to
501-5818-07 via ECO# WO_23128 on February 1, 2002.  Corrective action was made
available in Enterprise Services by issuing LEAP 1906 on February 6, 2002 and by
releasing a 3.3V DC-DC Converter FCO Kit (560-2681-01) via ECO# WO_23160, and by
issuing LEAP 1911 on February 7, 2002.

The below link to a Sun Alert has a "Restricted" Distribution.  Please print
and use this Sun Alert instead of the customer letter.  Communicate to your
*affected* customers only.  Typically, Sun Alerts have a wider distribution
on Contract and Free SunSolve but we have enhanced the Sun Alert program to
include what is known as "Targeted Sun Alerts" for affected customers only.

  http://sdpsweb.EBay/FIN_FCO/FCO/FCO_A0188-1_Dir/42977_public.html

Note: If you have questions please contact the Sun Alert Program Office.
      Ref;  http://sunalert.ebay/progorg.html

Please reference the below Customer Letter which has already been communicated
to some customers by Sun's Global Sales Operations (GSO) group;

  http://sdpsweb.EBay/FIN_FCO/FCO/FCO_A0188-1_Dir/Customer_Letter
Parts Affected: 
May 31, 2002
Implementation: 
---
| X |   MANDATORY (Fully Pro-Active)
 ---

 ---
|   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
 ---

 ---
|   |   UPON FAILURE
 ---
Replacement Time Estimate: 
0.5 hours
Special Considerations: 
All Sun Fire V880 systems shipped prior to February 1, 2002 may be affected.
Therefore, any Sun Fire V880 system with a serial number of 205xxxxx or later
can be presumed good, with the exception of systems from Reseller Channels
where a affected CPU/Mem Board may have been added by the Reseller prior
to shipment to their end-user.

To help identify affected customers the following URL provides a record of
all affected Daktari systems and xoptions shipped out of Manufacturing;

  http://sdpsweb.EBay/FIN_FCO/FCO/FCO_A0188-1_Dir/Customer_List
Corrective Action: 
Proactively contact all affected customers and replace the 3.3V DC-DC Converter
(Sun p/n 300-1437-03 or below) with DC-DC Converter FCO Kit (Sun p/n
560-2681-01).  Affected DC-DC Converters can be found on the CPU/Mem Board (Sun
p/n 501-5818-05 or below) not having an ECO rework lable as listed below.

Reference the following chart to determine if a CPU/Mem Board has an affected
DC-DC Converter:
 _______________________________________________________________
|   Part Number    |     ECO Label      |       Part Status     |
|__________________|____________________|_______________________|
|   501-5818-05    |                    |   Bad/Replace DC-DC   |
|    or below      |      None          |       Converter       |
|__________________|____________________|_______________________|
|   501-5818-05    |                    | Good DC-DC Converter  |
|    or below      |    WO_23160        |   Replaced in Field   |
|__________________|____________________|_______________________|
|   501-5818-05    |                    | Good DC-DC Converter  |
|    or below      |    WO_23128        |   Replaced in Depot   |
|__________________|____________________|_______________________|
|                  |                    | Good DC-DC Converter  |
|  501-5818-07     |      None          |   Replaced in Depot   |
|__________________|____________________|_______________________|
|                  |                    | Good DC-DC Converter  |
|  501-6360-XX     |      None          |  newer CPU/Mem Board  |
|__________________|____________________|_______________________|

NOTE: The 501-5818-06 was never released.  Check for ECO# WO_23128 label
      which will be located next to the system serial number (on the left
      side of the sytem).  If this ECO label is present, the system was
      updated with a new DC-DC Converter prior to shipment from the
      factory and is not affected.  Reference the following picture that
      shows the where these ECO labels are affixed in the factory.

        http://sdpsweb.EBay/FIN_FCO/FCO/FCO_A0188-1_Dir/MVC-013F.JPG

Please note that all CPU/Mem Boards below -07 have no dash or revision labels
applied to the CPU/Mem Board face plate.  Only the CPU/Mem Board part number
and serial number barcode is present.  If no dash/revision label is seen,
and there is no rework label applied (WO_23128 or WO_23160), rework is
required.  Part number 501-6360 is a newer version of the CPU/Mem Board
and is not impacted by this issue.

Instructions (in English) for installing the kit will be included in each kit.
These instructions may also be found at the below URL;

  http://sdpsweb.EBay/FIN_FCO/FCO/FCO_A0188-1_Dir/dc2dc.pdf

NOTE: These instructions contain an error in that it states rework is
      required if ECO label WO_23160 is not found on the faceplate of the
      CPU/Mem Board.  However, rework is not required if either of the
      following ECO labels are located on the CPU/Mem Board faceplate;

             WO_23160  or  WO_23128

Once the DC-DC Converter Kit is installed ensure that the ECO Label (included
in the kit) is applied to the CPU/Mem Board per the rework instructions
contained in the Kit.
Comments: 
This FCO must be implemented as quickly as possible, as Sun has communicated
to our customers that we will target implementation completion for no later
than March 29, 2002.
Billing Type: 
Warranty: Sun will provide parts at no charge under Warranty
           Service. On-Site Labor Rates are based on how the
           system was initially installed.

 Contract: Sun will provide parts at no charge. On-Site Labor Rates
           are based on the type of service contract.

 Non Contract: Sun will provide parts at no charge. Installation by
               Sun is available based on the On-Site Labor Rates
               defined in the Price List.

--------------------------------------------------------------------------
Implementation Footnote: 
________________________

i)   In case of Mandatory FCOs, Enterprise Services will attempt to contact
      all known customers to recommend the part upgrade.

ii)  For controlled proactive swap FCOs, Enterprise Services mission critical
     support teams will initiate proactive swap efforts for their respective
     accounts, as required.

iii) For Replace upon Failure FCOs, Enterprise Services partners will implement

     the necessary corrective actions as and when they are required.

--------------------------------------------------------------------------

All released FINs and FCOs can be accessed using your favorite network
browser as follows:

SunWeb Access:
______________

* Access the top level URL of http://sdpsweb.EBay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.

SunSolve Online Access:
_______________________

* Access the SunSolve Online URL at http://sunsolve.Central/

* From there, select the appropriate link to browse the FIN or FCO index.