Document Audience: | INTERNAL |
Document ID: | A0186-1 |
Title: | SunPCi II and SunPCi IIpro cards may not respond after rapid/successive power cycling. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | Mon Dec 03 00:00:00 MST 2001 |
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD CHANGE ORDER
(For Authorized Distribution by SunService)
FCO #: A0186-1
Status: active
Synopsis: SunPCi II and SunPCi IIpro cards may not respond after rapid/successive power cycling.Date: Dec/03/2001
Keywords:
SunPCi II and SunPCi IIpro cards may not respond after rapid/successive power cycling
SunAlert: N
Top FIN/FCO Report: No
Products Reference: SunPCi II and SunPCi IIpro cards
Product Category: Server / Other
Product Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
Systems Affected
------- --------
- A33 - Enterprise 420R -
- A25 - Enterprise 450 -
- A28 - Sun Blade 1000 -
- A26 - Enterprise 250 -
- A35 - Sun Fire 280R -
- A21 - Ultra 5 -
- A22 - Ultra 10 -
- A23 - Ultra 60 -
- A27 - Ultra 80 -
- A36 - Sun Blade 100 -
- E450 - Ultra Enterprise 450 -
- A34 - Enterprise 220R -
X-Options Affected
------------------
X2131A - - SunPCi II 600MHz, 64MB -
X2132A - - SunPCi IIpro 733MHz -
Parts Affected:
Part Number Description Model
----------- ----------- -----
375-3051-01 SunPCi IIpro 733MHz -
375-0131-04 SunPCi II 600MHz, 64MB -
(SCSI Devices)
Type Vendor Model SerialNumber(Min) SerialNumber(Max) Firmware
---- ------ ------- ------------------ ------------------ --------
N/A
References:
WWStopShip: P001-20001
Manual: 806-4788-12 SunPCI(tm) II Installation Guide
DPCO: 265
Manual: 806-4787-10 SunPCI(tm) Users Guide
FIN: I0739-1 Replacing Sun PCi 11 boards
Issue Description:
The OBP may not detect the SunPCi II or SunPCi IIpro card in the PCI
slot following rapid, successive power cycling of the system making
these cards inaccessible. Any applications that are dependent on these
cards and/or their associated devices will become unavailable.
During rapid power cycling, the Voltage Regulator on the card can
overheat, resulting in a card failure.
A limited number of SunPCi II and SunPCi IIpro cards shipped between
April 23rd 2001 and May 18th, 2001 are affected.
Root cause analysis at Sun's manufacturing vendor isolated the source
of the failures to a bad batch of voltage regulators. There is no
correlation between a board's serial number or date code. The only way
to determine if a board is affected is as follows. The affected
voltage regulators have a datecode of "0038". This regulator can be
found at board location U6. In order to check the datecode of the
voltage regulator the heat sink that covers this component must be
loosened. If this Semtech voltage regulator has a datecode of "0038"
it could experience this failure mode.
Corrective action was put in place within Sun Manufacturing on August
1, 2001 via Worldwide StopShip/Purge P001-20001, and Enterprise
Services on November 7, 2001 via DPCO 265.
Implementation:
---
| | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| X | UPON FAILURE
---
Replacement Time Estimate:
0.5 hours
Special Considerations:
Corrective Action:
Upon Failure replace 375-0131-04 with 375-0131-04 (with stopship label
P001-20001).
Upon Failure replace 375-3051-01 with 375-3051-01 (with stopship label
P001-20001).
Reworked spares will have DPCO Label on FRU Carton.
Identification of Suspect Part
------------------------------
Affected SunPCi II cards (Sun p/n 375-0131-04) will have a serial
number between 011957 and 016784, and will have a Semtech voltage
regulator with date code 0038. This regulator can be found at board
location U6.
Affected SunPCi IIpro cards (Sun p/n 375-3051-01) will have a serial
number between 000267 and 001043, and will have a Semtech voltage
regulator with date code 0038. This regulator can be found at board
location U6.
For detailed Card replacement procedures please refer Sun System
Handbook for instructions on Removing and Replacing the Cards.
Comments:
Billing Type:
Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on how the
system was initially installed.
Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.
Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of Mandatory FCOs, Enterprise Services will attempt to contact
all known customers to recommend the part upgrade.
ii) For controlled proactive swap FCOs, Enterprise Services mission critical
support teams will initiate proactive swap efforts for their respective
accounts, as required.
iii) For Replace upon Failure FCOs, Enterprise Services partners will implement
the necessary corrective actions as and when they are required.
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
______________
* Access the top level URL of http://sdpsweb.EBay/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
_______________________
* Access the SunSolve Online URL at http://sunsolve.Central/
* From there, select the appropriate link to browse the FIN or FCO index.
Supporting Documents:
____________________
Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.Central/.
* From there, follow the hyperlink path of "SunService Documentation" and
click on "FIN & FCO attachments", then choose the appropriate folder,
FIN or FCO. This will display supporting directories/files for FINs or
FCOs.
Internet Access:
_______________
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
________
Send questions or comments to [email protected]
---------------------------------------------------------------------------