Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Troubleshooting Sure Solution 1311380.1 : Sun Enterprise[TM] 10000: Troubleshooting IDN
In this Document
Applies to:Sun Enterprise 10000 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/AInformation in this document applies to any platform. PurposeThis document contains common errors and problems encountered when using Inter-Domain Networking (IDN) on the E10000 server.Last Review DateApril 6, 2011Instructions for the ReaderA Troubleshooting Guide is provided to assist
in debugging a specific issue. When possible, diagnostic tools are included in the document
to assist in troubleshooting.
Troubleshooting Detailsdomain_link reports IDN_NWR_SIZE conflicts with domain id XCheck the value of idn-smr-size in the eeprom image of all domains that are using IDN. This value must be the same across all domains.Also, consult the Sun Enterprise 10000 IDN Error Messages Guide located at http://download.oracle.com/docs/cd/E19065-01/servers.10k/806-5231-10/806-5231-10.pdf domain_link reports IDN state NOT SUPPORTEDSomething similar to the following is reported:ssp0:domain1% domain_link domain1 domain2Assuming the OS of the domain meets the requirements for IDN, and the IDN packages are installed...
When the driver loads it sets a "cookie" in BBSRAM of the bootproc. domain_link examines the BBSRAM and if the cookie is not found the domain is tagged as NOT SUPPORTED. ifconfig'ing the idn interface will automatically load the driver. Referenceshttp://download.oracle.com/docs/cd/E19065-01/servers.10k/806-5231-10/806-5231-10.pdfAttachments This solution has no attachment |
||||||||||||
|