Solution Type Troubleshooting Sure Solution 1219543.1 : VSM - Troubleshooting FSC7C54 Proc Copy Switch
Troubleshooting notes for TSC Support In this Document
Applies to:Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0Information in this document applies to any platform. PurposeSteps to take to determine cause and next steps when receiving FSC7C54 (Proc copy switch) alert.Last Review DateSeptember 29, 2010Instructions for the ReaderA Troubleshooting Guide is provided to assist
in debugging a specific issue. When possible, diagnostic tools are included in the document
to assist in troubleshooting.
Troubleshooting Details1. Pull VTSS logs and crunch them (see Doc id #1232935.1)2. Review hic_stat.dia and determine if proc copy switch was manual due to CSE maintenance or hardware issue. A. Search for "CSE Entering Maintenance Menus" prior to MIM with FSC7C54, and see if CSE performed maintenance. For example, non-disruptive code upgrade requires proc copy switch to apply code on ISPs to non-master. Or if ISP is IML'ed for a GSR (Guided Service Repair) a proc copy switch may be required. In these cases, no further action is required. B. If not CSE induced, review logs for other causes and take appropriate action. Attachments This solution has no attachment |
||||||||||||
|