In this Document
Purpose
Last Review Date
Instructions for the Reader
Troubleshooting Details
Applies to:
Sun Storage 6780 Array - Version: Not Applicable and later [Release: NA and later ] Sun Storage 6580 Array - Version: Not Applicable and later [Release: NA and later] Sun Storage Common Array Manager (CAM) - Version: 6.2 to 6.5 [Release: 6.2 to 6.5] Information in this document applies to any platform.
Purpose
This document is intended to provide a basic overview on how to troubleshoot faults with the array RAID controller cache backup device.
Please validate that each troubleshooting step below is true for your
environment. Each step will provide instructions via a link to a
document, for validating the step and taking corrective action as
necessary. The steps are ordered in the most appropriate sequence to
isolate the issue and identify the proper resolution. Please do not
skip a step.
Symptoms:
- Critical Fault for Cache Backup Device Failed(xx.66.1251)
- Array Log Events for Cache Backup Device (Event 0x7500)
- Cache Backup device shows as Failed in the user interface
- Cache Backup device shows as Unknown in the user interface
- Controller Seven Segment Display shows OS+ CF+ F#+ blank-
Last Review Date
June 9, 2010
Instructions for the Reader
A Troubleshooting Guide is provided to assist
in debugging a specific issue. When possible, diagnostic tools are included in the document
to assist in troubleshooting.
Troubleshooting Details
Step 1) Verify the existence of a critical fault for Cache Backup Device Failed Critical Fault
Reference <Document: 1021057.1> Verify Sun StorageTek[TM] 2500 and Sun Storage[TM] 6000 Critical Faults via the User Interface
- If there is no critical fault, it is unlikely that a backup device has completely failed, but may require additional checks. Continue to Step 2.
- If there is a critical fault, go to Step 5.
Step 2) Verify the 7-segment display on the array controller module.
Another indicator of a Cache Backup Device fault is the 7-Segment Display on the Array RAID Controller. This display also serves as the array controller module Tray ID indicator. It is located in the rear(cable side) of the tray. For more information on the 7-segment display:
Reference <Document: 1021110.1> Sun Storage[TM] 6180, 6580, and 6780 Array Controller 7-Segment Display.
- If the display shows a repeating pattern:
OS+ CF+ F#+ blank-
Note: The hash(#) symbol represents a number 1 through 4 which represents the faulty cache backup device slot.
Go to Step 5.
- If the display shows another repeating pattern other than that shown above, the problem is not a Cache Backup Problem, but something else with the controller. Please reference <Document: 1021113.1> Troubleshooting Sun StorageTek[TM], Sun StorEdge[TM], and Sun Storage[TM] RAID Controller Failures
- If the display shows the tray ID(defaults to 99) of the module, OR you are unable to confirm the display, continue to Step 3.
Step 3) Verify the state/status of the Cache Backup Device on your controller
Follow the instructions below to look at the state and status of your Cache Backup Devices, based on your user environment:
Sun StorageTek Common Array Manager:
Browser:
- Expand Storage Arrays in the left menu pane
- Expand your storage array name in the left menu pane
- Expand Troubleshooting in the left menu pane
- Click on FRUs
- In the right display pane, click on Cache Backup Device
SSCS CLI:
sscs list -d array_name -t cacheBackup fru
Sun StorageTek SANtricity Storage Manager:
GUI:
- Launch SANtricity
- Double Click on your array name to open the Array Management Window
- In the left pane click on the controller icon for the controller DIMMs you want to view.
- In the right pane the Cache Backup Device status, for each slot, will be listed after the base controller information.
SMcli:
SMcli -n <array name> -c "show storageArray profile;"
NOTE: The Cache Backup Device information will be listed in the CONTROLLERS section of the resultant SMcli output.
- If your Backup Device is in an Enabled/OK/Optimal state/status, continue to Step 4
- If your Backup Device is in a Failed state or status, go to Step 5.
- If your Backup Device is in an Unknown status, and the Controller is ONLINE, go to Step 6.
NOTE: The Cache Backup Device information will be Unknown or Unavailable if the controller it resides on is currently OFFLINE. This applies for all management software.
Step 4) Verify existence of Cache Backup Device Failed messages in array event logs
The Cache Backup Device can have a handful of messages
Sun StorageTek Common Array Manager:
Browser
- Expand Storage Arrays in the left menu pane
- Expand your storage array name in the left menu pane
- Expand Troubleshooting in the left menu pane
- Click on Events
- In the right pane, click on the -|-> icon. If you mouse over it it will state Advanced Filter.
- Set Event to Log Events
- Set Event Type to Component
- Set Read the last X Kbytes From Log File to 100
- Set String Filter to CacheBackupDevice
- Click on the Details of any alarm that is shown.
- Review the Description Field
- Get the value of the array log event ID from the description
Note: The filter in item "9." above is case sensitive.
Example:
Description : Apr 08 21:31:31 6780-array Tray.99.Controller.A.CacheBackupDevice.USB3: [ID 0x1901] NOTICE: Cache memory dimm is missing
SSCS CLI:
Get the list of events:
sscs list -d array_name -t LogEvent -f CacheBackupDevice event
Note: The -f option's argument is case sensitive. Get the event details:
sscs list -d array_name event event_id
Get the value of the array log event ID from the description:
Example:
Description : Apr 08 21:31:31 6780-array Tray.99.Controller.A.DIMM01: [ID 0x7500] NOTICE: Persistent cache backup device has failed
SANtricity Storage Manager
GUI
- Launch SANtricity
- Double Click on your array name to open the Array Management Window
- Click on the Advanced Menu
- Click on the Troubleshooting Sub-Menu
- Click on View Event Log
- Un-Check View Only Critical Events
- Click on the Component Type field header to sort the events
- Look for Cache Backup in the list of events
- For any Cache DIMM event, highlight it, and check the View Details box
- Get the value of the Event type field for each DIMM event.
SMcli
Get the list of events by saving off the event log.
SMcli -n array_name -c "save storageArray allEvents file=\"some/file/path/log.txt\";"
Open a text viewing application to look at the individual events. Get the value of the Event type field for each Cache Backup event.
Example Event
Date/Time: 6/8/10 21:52:00 ET Sequence Number: 12345 Event Type: 7500 Description: Persistent cache backup device has failed
- If there is the existence of an event log ID of 0x7500, go to Step 5.
- If there are no 0x7500 Event ID's, and your array controller is Online/OK, you have verified that the Cache Backup Device is working optimally. No further work is required.
Step 5) Open a Service Call with Oracle to have the Cache Backup Device indicated replaced
The Cache Backup Device slot for the controller is indicated in either the 0x7500 Event, the Seven Segment Display, or the critical fault, is failed, and requires replacement. No further troubleshooting is necessary.
Please open a service call with Oracle with:
Reference <Document: 1002514.1> Collecting Support Data for Arrays Using Sun StorageTek[TM] Common Array Manager
Reference <Document: 1014074.1> Collecting Support Data for Arrays Using Sun StorageTek[TM] SANtricity Storage Manager
OR
- Cache Backup Slot location
- Array Critical Faults
- Array Event Log
- Seven Segment Display Code cited.
Step 6) Open a Service Call with Oracle to for further research
Please provide a Support Data Collection:
Reference <Document: 1002514.1> Collecting Support Data for Arrays Using Sun StorageTek[TM] Common Array Manager
Reference <Document: 1014074.1> Collecting Support Data for Arrays Using Sun StorageTek[TM] SANtricity Storage Manager
Attachments
This solution has no attachment
|