Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Troubleshooting Sure Solution 1020884.1 : How to Collect a Forced Crash Dump of a Hanging Solaris Guest Domain
PreviouslyPublishedAs 266628
Applies to:Sun Netra T5220 Server - Version: Not ApplicableSun Netra T5440 Server - Version: Not Applicable and later [Release: N/A and later] Sun Fire T1000 Server - Version: Not Applicable and later [Release: N/A and later] Sun Netra T2000 Server - Version: Not Applicable and later [Release: N/A and later] Sun Fire T2000 Server - Version: Not Applicable and later [Release: N/A and later] All Platforms PurposeThis Document refers the Steps to collect the crash dump of a hanging Guest domain.Purpose/Scope: ___________ This document refers to steps to collect forced crash dump for a hanging Domain . Symptom: Guest LDOM not responding or Guest LDOM Hanging. Last Review DateFebruary 3, 2011Instructions for the ReaderA Troubleshooting Guide is provided to assist
in debugging a specific issue. When possible, diagnostic tools are included in the document
to assist in troubleshooting.
Troubleshooting DetailsResolution1. ldm panic/panic-domain 2. Another way to do this is through VNTSD options ~# --Send break Debugging requested; hardware watchdog suspended. c)ontinue, s)ync, r)eset? s Once the crash dump is collected please follow 1020212.1 to collect LDOM related logs.
To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community, Oracle Solaris System Administration Community. Product Sun Fire T2000 Server Sun Fire T1000 Server Sun Netra T2000 Server Sun Netra T5220 Server Sun Netra T5440 Server Netra T5220 AC Sun SPARC Enterprise T5220 Server Sun SPARC Enterprise T5240 Server Sun Blade T6300 Server Module Sun Blade T6320 Server Module Sun SPARC Enterprise T5120 Server Sun SPARC Enterprise T5140 Server Sun Blade T6340 Server Module Sun SPARC Enterprise T2000 Server Sun SPARC Enterprise T5440 Server Sun SPARC Enterprise T1000 Server Internal Comments This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the "Document Feedback" alias(es) listed below: Normalization Lead: [email protected] Normalized, ldom, ldm, Hanging Attachments This solution has no attachment |
||||||||||||
|