Applies to:Sun SPARC Enterprise T2000 ServerSun SPARC Enterprise T5120 Server Sun SPARC Enterprise T5140 Server Sun SPARC Enterprise T5220 Server Sun SPARC Enterprise T5240 Server All Platforms PurposeDescriptionThis document would explain the details of troubleshooting LDOM Guest domain network issues Symptoms: One of more of the following are observed or described when one have issue binding VCPU/MAU:
This document describe in the context during guest domain creation. Adding of resources to an active domain can also fail due to lack of additional resources to be assigned to a domain. The corrective actions are the same as described here. Last Review DateJanuary 28, 2011Instructions for the ReaderA Troubleshooting Guide is provided to assist
in debugging a specific issue. When possible, diagnostic tools are included in the document
to assist in troubleshooting.
Troubleshooting DetailsRelated Documents:For more information on creation of LDoms guest domains, please refer to following references: - Beginners Guide to LDOMs (820-0832) availabe at http://www.sun.com/blueprints. - Logical Domains (LDoms) X.X.X Administration Guides, which are available on http://www.oracle.com/technetwork/documentation/vm-sparc-194287.html . Additional information specific to the software release is available on http://www.oracle.com/technetwork/documentation/vm-sparc-194287.html as: - LDOMs Release Notes. - Release Notes for the specific Solaris release. Up to date information on LDoms is available at http://www.sun.com/ldoms/ . Steps to Follow Please validate that each troubleshooting step below is true for your environment. The steps will provide instructions or a link to a document, for validating the step and taking corrective action as necessary. The steps are ordered in the most appropriate sequence to isolate the issue and identify the proper resolution. Please do not skip a step Before attempting the following steps, please ensure the user account used has the appropriate RBAC profiles for LDOMs Management. The user either has to have to "LDoms Management" profile or just login as root. For more information on user authorization, please refer to the Security chapter of the LDoms Administration Guide. Step 1. Verify link configuration and vnet settings in LDOM. See 1020016.1 Verify link configuration and vnet settings in LDOM. Step 2. Network configuration issue. See 1020018.1 Confirm network settings are correct. At this point, if you have validated that each troubleshooting step above is true for your environment, and the issue still exists, further troubleshooting is required. Provide an Explorer output and open a Service Request. See 1020212.1 Data Collection for troubleshooting LDom issues. Product Logical Domain Manager 1.0.1 Sun Fire T2000 Server Sun Fire T1000 Server Sun Netra T2000 Server Sun Netra T5220 Server Sun Netra T5440 Server Netra T5220 AC Sun SPARC Enterprise T5220 Server Sun SPARC Enterprise T5240 Server Sun Blade T6300 Server Module Sun Blade T6320 Server Module Sun SPARC Enterprise T5120 Server Sun SPARC Enterprise T5140 Server Sun Blade T6340 Server Module Sun SPARC Enterprise T2000 Server Sun SPARC Enterprise T5440 Server Sun SPARC Enterprise T1000 Server Internal Comments This document contains normalized content and is managed by the the Domain Lead (s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the "Document Feedback" alias(es) listed below: Domain Lead: Normalization Lead: [email protected] Normalized, ldom, ldm, guest , domain, network, issues, vnet, vsw, vswitch, virtual network interface, hyrbrid I/O, DHCP, audited Attachments This solution has no attachment |
||||||||||||
|