Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Troubleshooting Sure Solution 1012984.1 : Troubleshooting Sun Storage [TM] 33x0/351x Power Supply Problems
PreviouslyPublishedAs 217782
Applies to:Sun Storage 3320 SCSI ArraySun Storage 3310 Array Sun Storage 3510 FC Array Sun Storage 3511 SATA Array All Platforms PurposeDescriptionThis document provides hints to better identify the existence of power-supply problems in Sun Storage[TM] 3510 FC Arrays, 3511 SATA Arrays, and 33x0 SCSI Arrays. The Failure symptoms may include any of the following: - "Failed or absent power supply" reported by " - Amber Power Supply LED - Power supply eventlog messages Last Review DateDecember 21, 2010Instructions for the ReaderA Troubleshooting Guide is provided to assist
in debugging a specific issue. When possible, diagnostic tools are included in the document
to assist in troubleshooting.
Troubleshooting DetailsSteps to FollowPlease validate that each troubleshooting step below is true for your environment. Each step will provide instructions via a link to the document, for validating the step and taking corrective action as necessary. The steps are ordered in the most appropriate sequence to isolate the issue and identify the proper resolution. Please do not skip a step.” NOTE: This is a sub-set of 1. Verify the power supply hardware status is OK by issuing the following 2 sccli commands: - sccli> show fru - sccli>show enclosure-status Example for 3510 : sccli> show fru Voltage 0 OK 370-5398 031354 voltage=5.300V 2. Verify the Power Supply LED is green. 3. Verify the eventlog or persistent-event log by issuing the
sccli> show event or sccli> show persistent-event to determine that the array is not reporting failures or absent events. 4. For 35x0 arrays, review For example: Thu Jun 8 18:00:44 2006 [3F3f] #5542: SES Device on StorEdge Array SN#80502xx CH2 ID12: ALERT: PS 0 power supply state changed to critical Thu Jun 8 18:00:44 2006 [3F3f] #5543: SES Device on StorEdge Array SN#80502xx CH2 ID12: ALERT: PS 1 power supply state changed to critical Thu Jun 8 18:01:42 2006 [3Fdf] #5544: SES Device on StorEdge Array SN#80502xx CH2 ID12: NOTICE: PS 0 power supply is no longer critical Thu Jun 8 18:01:42 2006 [3Fdf] #5545: SES Device on StorEdge Array SN#80502xx CH2 ID12: NOTICE: PS 1 power supply is no longer critical 5. Verify the troubleshooting steps in the Power Supply and Fan Module section in the latest revision of the
6. If there are no problems encountered with the power
supplies, refer back to Change History Date: 2010-12-21 User Name: [email protected] Action: Update and Currency Attachments This solution has no attachment |
||||||||||||
|