Solution Type Troubleshooting Sure Solution 1012423.1 : Sun StorEdge [TM] L25/L100 Tape Library: I added a new tape drive, why can't I use it?
PreviouslyPublishedAs 217125
Applies to:Sun Storage L100 Tape LibrarySun Storage L25 Tape Library All Platforms PurposeCustomer added another tape drive to an L25/L100, but Solstice Backup fails to add the drive to the backup configuration.Likely error message... "this robot can only be configured for 4 drives" Last Review DateAugust 25, 2010Instructions for the ReaderA Troubleshooting Guide is provided to assist
in debugging a specific issue. When possible, diagnostic tools are included in the document
to assist in troubleshooting.
Troubleshooting DetailsSteps to FollowThe operating system can see the tape drive. /dev/rmt has been built. Problem basically is the tape drive has not been configured into the library from either the front panel or via the Prism Management board. This has to be done before the system can use the new tape drive. Reference the L25/L100 install guide that came with the library. If the guide is not available, an electronic copy can be found here...
https://support.oracle.com/handbook_private/Systems/L25_shared/docs.html Here you will find two pdf files, one is the users guide and the other is the install guide. In the users guide, chapter 3, page 69, will take you through the process of making changes to the library, ie. adding or removing a tape drive. Adding/disabling/enabling a tape drive can also be accomplished using the Prism Management board/interface card. This is a web enabled interface to the library itself. (if it was purchased with the library) The PMC has an ip address that the customer supplied, and should be accessed like this from a browser... http:// There you will see the Prism gui, on the left you will see some menu picks, pick ALERT-Library Management, there you will see more picks, ie. Library Status Pick Library Configuration, then you will see ... Library N/A SCSI 0 There will be some pull downs available for the BUS ID and the New BUS ID pull downs. From here you can change the scsi id of a tape drive or robot and change/add a tape drive. Click "Apply" to save the changes you wish to make. Then reboot the library from the PMC card and you will be ready to go. Make the changes to your backup software and you should be done. This can all be found in the reference manual that came with the PMC card, or please contact Sun for an electronic pdf copy. This process is found on page 35 and is very detailed with illustrations and examples. Product Sun StorageTek L25 Tape Library Sun StorageTek L100 Tape Library Internal Comments Internally, please go to ... http://tape.central/Products/L100/index.html And click on the appropriate manuals, including the
PMC300 user docs. This is the Prism Management Card documents This document about the PMC card, is not available outside of our internal
webpages. You will have to download this manual for your customer should they
SBU, EBS, NBU, Solstice Backup, Net Backup, Veritas, Legato, L25, L100, L25/L100, PMC, Prism Management Card Change History Unarchived 01/12/10 by Joey Sobeck, requested by Glen Foley Date: 2005-04-21 User Name: 7058 Action: Approved Comment: Doc OK as is. Updated link OK. Attachments This solution has no attachment |
||||||||||||
|