Description
Troubleshooting SCSI Devices from the Operating System

Steps to Follow
Please validate that each troubleshooting step below is true for your environment. The steps will provide instructions or a link to a document, for validating the step and taking corrective action as necessary. The steps are ordered in the most appropriate sequence to isolate the issue and identify the proper resolution. Please do not skip a step.

Step 1 - Identify which device path is not seen by looking at format or /var/adm/messages.This will be needed in step 2.

Example:

     /devices/pci@1f,4000/pci@5/scsi@4

Step 2 - Verify the HBA can be seen from the OS

Refer to < Document: 1005314.1 > Sun StorageTek 33x0 SCSI Array: How to verify SCSI HBA Connectivity

Step 3 - Sun Solaris only supports Veritas DMP for SCSI multipathing, please verify Multipathing is enabled correctly.

Refer to < Document: 1011302.1> "Verifying DMP Health" for VxDMP

Step 4 - Verify StorEdge array hardware and configuration is optimal.

Refer to < Document: 1005313.1 > Troubleshooting Sun StorEdge 33x0/351x Configuration

Step 5 - Verify lun setting within the sd.conf file.

Refer to Editing the sd.conf file , Appendix D2, in the Sun StorEdge 3000 Family Installation, Operation, and Service Manual available from http://www.oracle.com/technetwork/indexes/documentation/index.html/

At this point, if you have validated that each troubleshooting step above is true for your environment, and the issue still exists,
further in-depth troubleshooting is required. Please provide supporting data and open a Service Request.





Product
Sun StorageTek 3310 SCSI Array
Sun StorageTek 3320 SCSI Array

Internal Comments
This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below:

Domain Lead: [email protected]
Feedback Alias: [email protected]



3110, 3120, 3310, 3320, SCSI, normalized
Previously Published As
89050

Change History
Date: 2007-08-23
User Name: 7058
Action: Approved
Comment: Links fixed.
Version: 8
Date: 2007-08-23
User Name: 7058
Action: Update Started
Comment: External sunsolve links pointing to internal sunsolve server.
Version: 0
Date: 2007-07-03
User Name: 7058
Action: Approved
Comment: This doc is finally ready to publish.

Notes for Normalizaton:
Subset of: N/A
Subset Root path: N/A
References: 86532, 89038, 89031
Project: Minnow Normalization
Version: 7



Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.