In order to provide you the most accurate fix, please validate that each statement under the symptoms below is true for your environment. These symptoms will hyperlink you into a relevant content that will 1) tell you how to validate the listed symptom and 2) how to fix the symptom if it is true for your environment. The listed symptoms are ordered in the most appropriate sequence to isolate the issue and be certain about the related fix. Please do not skip a step.

Applies to:

Sun Storage 3310 Array
Sun Storage 3320 SCSI Array
All Platforms

Purpose


Symptoms:


This document will assist with troubleshooting 33x0/3120 Arrays with one or more of the following symptoms:

- Cannot see all or some of my devices in format or from OBP

- Data phase parity

- SCSI transport errors

- SCSI bus resets

- Audible alarms

- Component alarms in event logs

- Speed of host channel showing as ASYNC

- Amber / No LED

Examples:

scsi: [ID 107833 kern.warning] WARNING:/pci@1c,600000/scsi@2,1 (glm1):
Connected command timeout for Target 0.0
genunix: [ID 408822 kern.info] NOTICE: glm1: fault detected in device;
service still available
genunix: [ID 611667 kern.info] NOTICE: glm1:Connected command timeout for Target 0.0
glm: [ID 280919 kern.warning] WARNING:ID[SUNWpd.glm.cmd_timeout.6017]
scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2,1 (glm1):
Target 0 disabled wide SCSI mode
glm: [ID 681974 kern.warning] WARNING:ID[SUNWpd.glm.sync_wide_backoff.6012]
scsi: [ID 107833 kern.warning] WARNING:/pci@1c,600000/scsi@2,1 (glm1):
Target 0 reverting to async. Mode
glm: [ID 802533 kern.warning] WARNING:ID[SUNWpd.glm.sync_wide_backoff.6013]
scsi: [ID 107833 kern.warning] WARNING:/pci@1c,600000/scsi@2,1 (glm1):
got SCSI bus reset
sccli> show channels
Ch  Type    Media   Speed   Width  PID / SID
--------------------------------------------
0 Drive SCSI 80M Wide 6 / 7
1 Host SCSI 80M Wide 0 / N/A
2 Drive SCSI 80M Wide 6 / 7
3 Host SCSI ASYNC Narrow N/A / 1
6 RCCOM FC(L) 1G Narrow N/A / N/A
7 Host LAN N/A Serial N/A / N/A


Last Review Date

January 31, 2011

Instructions for the Reader

A Troubleshooting Guide is provided to assist in debugging a specific issue. When possible, diagnostic tools are included in the document to assist in troubleshooting.

Troubleshooting Details

Steps to Follow:

NOTE :  This document is linked from :Troubleshooting Sun StorEdge[TM] 33x0/351x Hardware 

The steps below will help to understand some of the common problems that occur when cabling 33x0 arrays.

Troubleshooting Steps:

Note: Even though the following links appear to be the same they are not, they point to different sections and chapters in the manuals that cover proper cabling of the arrays.

Sun Cluster 3.1 - 3.2 With Sun StorEdge 3310 or 3320 SCSI RAID Array Manual for Solaris OS
  1. Check I/O Module LEDs for any clues:

    33x0:

     Section 6.1 :  Sun StorEdge 3000 Family Installation, Operation, and Service Manual, Sun StorEdge 3310 SCSI Array.

    3120 :

      Section 6.1: Sun StorEdge 3000 Family Installation, Operation, and Service Manual, Sun StorEdge 3120 SCSI Array.

  2. Physically inspect cables for any bent pins or damaged cables.  If hardware problems are encountered with the cables, replace as needed.  Reference supported cable type links in earlier step for part numbers.

  3. If connecting a 3310 array to an Ultra320 HBA please reference  Resolving SCSI bus reset & transport errors on Sun StorEdge[TM] 3310 SCSI array with Ultra320 SCSI HBA.

  1. If no problems found during the course of this document please refer back to :   Troubleshooting Sun StorEdge[TM] 33x0/351x Hardware .

     



Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback