Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Troubleshooting Sure Solution 1005601.1 : Validating Sun StorEdge[TM] 6920 Remote Replication details and state
PreviouslyPublishedAs 207775 Description This document provides the basic steps to review remote replication state, configuration, and settings information using the Browser or SSCS user interfaces. Use this document if:
For basic administrative tasks on the Sun StorEdge[TM] 6920 System, please reference Steps to Follow Replication A. Validate Replication set and Volume Summary Only the volume type will change, to replicated, when a volume is used for replication. Refer to <Document: 1009974.1> Sun StorEdge[TM] 6920 System: Validating Volume State and Details for volume information. The basic usage for listing all of the replication sets can be gotten by: SSCS sscs list repset
Note that only replication sets that are part of the storage domain specified will be listed. If no domain option is specified, the domain DEFAULT is assumed. BUI
This will display:
For a more detailed view of a replication sets continue to Step B.. For other volume types, return to the table in Step 2 of <Document: 1009915.1> Troubleshooting Sun StorEdge[TM] 6920 Configuration Problems If a replication set cannot be seen, or has a condition other than OK go to Step C. B. Validating Replication Set Details This step details collection for Replication sets SSCS sscs list repset <repset_name> Note that only repsets that are part of the storage domain specified will be listed. If no domain option is specified, the domain DEFAULT is assumed. This will display the following field information:
BUI
This will display 3 sections: Details
Role Properties
Replication Bitmap
NOTE: Replication Progress of Suspended, Replicating, or Synching are all normal states. Suspended means no real-time data is being transmitted. Replicating means that data is being transmitted in real-time. Syncing means that data is being transmitted in real-time, but is also being silvered. Consider the following actions:
C. Data Collection for Missing or Incorrect Replication Sets Information Please Collect the following information from both the primary and secondary arrays:
And contact Sun Support Product Sun StorageTek 6920 System Sun StorageTek 6920 Maintenance Update 2 Sun StorageTek 6920 Maintenance Update 1 Internal Comments Validate service and perform health check of array: This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: [email protected]
Reference <Document: 1007129.1> : Validating Services on a Sun StorEdge 6920 Service Processor
Reference <Document: 1005447.1> : Sun StorEdge[TM] 6920 Health Checklist
Provide the following:
6920, remote replication volume, details, sscs, BUI, size, list, normalized, remote, replication, sets, audited Previously Published As 90711 Change History Date: 2007-09-24 User Name: 71396 Action: Approved Comment: Performed final review of article. No changes required. Publishing. Version: 3 Date: 2007-09-24 User Name: 71396 Action: Accept Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|