Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-75-1005248.1
Update Date:2009-09-20
Keywords:

Solution Type  Troubleshooting Sure

Solution  1005248.1 :   Sun Ultra[TM] 40 Workstation Minimum Memory Configuration Testing Guidelines  


Related Items
  • Sun Ultra 40 Workstation
  •  
Related Categories
  • GCS>Sun Microsystems>Desktops>Workstations
  •  

PreviouslyPublishedAs
207347


Description

When troubleshooting a possible memory problem it can be helpful to know what is the least amount of memory that can be installed, and where it can be installed. Testing in a minimum configuration can help isolate a failure that
could be DIMM or system board related.



Steps to Follow
  !!!!NOTE!!!! The information below is strictly for troubleshooting use only
and are NOT supported memory configurations. 

The system can be reduced to one DIMM and still power on and run diagnostics. The location that one DIMM can be installed is any of the four "DIMM0" sockets. They are marked with an "*" in the motherboard diagram below. Note that the format of the DIMM locations in the diagram is:

            silk screened on board/logical name used by diagnostics
              ====================== DIMM7/socket C1_DIMM1, Bank3
              ====================== DIMM6/socket C1_DIMM0, Bank3 *
              ====================== DIMM5/socket C1_DIMM1, Bank2
              ====================== DIMM4/socket C1_DIMM0, Bank2 *
--------------
|            |
|            |
|            |             F
|            | CPU1        A
|            |             N
|            |
--------------             T
R
--------------             A
|            |             Y
|            |
|            |
|            | CPU0
|            |
|            |
--------------
              ====================== DIMM0/socket C0_DIMM0, Bank0 *
              ====================== DIMM1/socket C0_DIMM1, Bank0
              ====================== DIMM2/socket C0_DIMM0, Bank1 *
              ====================== DIMM3/socket C0_DIMM1, Bank1


Product
Sun Ultra 40 Workstation

dimms, ultra, ultra40, diags, memory, troubleshooting
Previously Published As
85116

Change History
Date: 2006-04-13
User Name: 7058
Action: Approved
Comment: Trademarked where needed.
Checked for duplicates - none located.
Corrected 2 spelling errors / 1 typo.
Took indents out of paragraphs so that text does not appear preformatted.
OK to publish.
Version: 3
Date: 2006-04-12
User Name: 7058
Action: Accept
Comment:
Version: 0
Date: 2006-04-12
User Name: 93481
Action: Approved
Comment: this document is accurate and looks good
Version: 0
Date: 2006-04-12
User Name: 35315
Action: Approved
Comment: thanks
Version: 0
Date: 2006-03-28
User Name: 35315
Action: Created
Comment:
Version: 0
Product_uuid
7b070932-47f1-11da-ac39-080020a9ed93|Sun Ultra 40 Workstation

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback