Solution Type Troubleshooting Sure Solution 1003642.1 : Diagnosing Netra [TM] CT Alarm Card issues
PreviouslyPublishedAs 205143 Description In some situations an alarm card in a Netra CT system may hang. The following steps can be used to diagnose the situation. Steps to Follow In order to run APOST and alarmdiag, connect to the alarm card, and type the following command: cli> diagconf -d which display the parameter (like OBP parameter, but it is for the alarm card only). And use: cli> diagconf -s <commnd value> to set the following parameters: diag-switch=true verb-mode=true stop-on-error=true diag-level=max Then, power-cycle the alarm card, it will execute the APOST. alarm2test is part of the SUNWvts. You can run alarm2test from the VTS menu or directly from the command line. Both alarm2test and alarmtest can be found in /opt/SUNWvts/bin. To run POST, set the OBP parameter to the following: diag-switch?=true diag-level=max and power-cycle the system. At OBP, type: ok> obdiag to execute the OBDiag. There is a menu for OBDiag that you could slect specific tests to run. For more references on netra CT troubleshooting, please refer to: Netra CT Server Service Manual (PN: 816-2482) Part II Troubleshooting the System 4.3 Troubleshooting the System Using Diagnostic Software 4.4 Troubleshooting the system Using the Power-On-Self Test Product Netra ct 400 Server Netra CT 410 Server Netra ct 800 Server Netra CT 820 Server Netra CT 810 Server netra CT, alarm card, AC Previously Published As 80845 Change History Date: 2005-10-13 User Name: 31620 Action: Approved Comment: Verified Metadata - ok Verified Keywords - ok Verified still correct for audience - currently set to contract Audience left at contract as per FvF http://kmo.central/howto/FvF.html Checked review date - currently set to 2006-03-22 Checked for TM - added [TM] to title for Netra Publishing under the current publication rules of 18 Apr 2005: Version: 3 Date: 2005-10-12 User Name: 31620 Action: Accept Comment: Version: 0 Date: 2005-10-12 User Name: 77342 Action: Approved Comment: Ready to go Version: 0 Date: 2005-10-06 User Name: 77342 Action: Accept Comment: Version: 0 Date: 2005-10-06 User Name: 45570 Action: Approved Comment: we need more info on the Netra CTs for our OEM customers. Hanging ACs have beome an issue at Lucent. Version: 0 Date: 2005-03-22 User Name: 45570 Action: Created Comment: Version: 0 Product_uuid 299bd26e-0a18-11d6-85ae-b00895a52321|Netra ct 400 Server bf89fb96-99cf-4e7b-8681-152c788171f7|Netra CT 410 Server 29a04d1c-0a18-11d6-8e54-e4fcf1214b85|Netra ct 800 Server 3e7ab78e-277b-11d8-8845-080020a9ed93|Netra CT 820 Server a70f8b46-058a-4c49-b283-9709eb6ef37d|Netra CT 810 Server Attachments This solution has no attachment |
||||||||||||
|