Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1320584.1 : KMS/OKM - How to Pull ELOM Event Logs
In this Document
Applies to:Oracle Key Manager - Version: 2.0.0Information in this document applies to any platform. GoalHow to pull ELOM event logs.SolutionKMS ELOM report event logs errors under GUI, System Monitoring/Event log Tab.If errors/warnings exists and require detail analysis they must be pulled off ELOP using ipmitool utility. Download ipmitool from MOS patches - patch number 10319932. Tool runs on Windows and Solaris. Once installed run the following to extract event logs: # ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> sel elist # ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> fru # ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> sensor # ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> sunoem led get all # ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> sunoem sbled get # ipmitool -I lan -H <ILOM IP address> -U <ILOM Username> sdr elist Attachments This solution has no attachment |
||||||||||||
|