Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1319791.1 : How to Replace a Fabric Expansion Module in a X6270:ATR:2306:0
In this Document
Applies to:Sun Blade X6270 Server Module - Version: Not ApplicableInformation in this document applies to any platform. GoalHow to remove and replace a Fabric Expansion Module (FEM) in a Sun Blade X6270 Server Module
SolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) Field Engineer skills DELIVERY REQUIREMENT: Schedule with maintenance window Estimate AP Duration = 0.5 hours FIELD ENGINEER INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : WHAT ACTION DOES THE ENGINEER NEED TO TAKE: Replace a FEM Card 1. Power off the server and remove the server from the chassis. Caution - After removing the server from the chassis insert a filler panel into an empty slot to reduce the possibility of a system shutdown. 2. Remove the cover from the server. 3. Perform one of the following: * Remove the existing FEM board. or * Remove protective shipping cap from the FEM connector. 4. Perform the following steps to install the FEM board: a. Slide the FEM board at an angle into the support bracket b. Press the FEM board carefully into the connector. 5. Install the cover on the server. OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: PARTS NOTE: REFERENCE INFORMATION: Service Manual: http://download.oracle.com/docs/cd/E19658-01/