Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1319789.1
Update Date:2011-05-06
Keywords:

Solution Type  Technical Instruction Sure

Solution  1319789.1 :   How to Replace a X6270 REM 4620A:ATR:2305:0  


Related Items
  • Sun Blade X6270 Server Module
  •  
Related Categories
  • GCS>Sun Microsystems>CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Blade X6270 Server Module - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Goal

How to remove and replace a RAID Expansion Module 4620A in a Sun Blade X6270 Server Module

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Field Engineer skills

DELIVERY REQUIREMENT:
Schedule with maintenance window

Estimate AP Duration = 45 min

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Replace a REM Card

Note: With the cover off of the server module, determine whether the REM battery is attached directly onto the motherboard or on the REM card 4620A.

Replace a REM Card 4620A When the REM Battery Is Installed on the REM Card

1. Remove the existing REM card by sliding it at an angle out of the support bracket.
2. Swap the REM battery from the existing REM card to the new REM card.
3. Replace the REM card by sliding the new card at an angle into the support bracket, then pressing it carefully into its connector.
4. Install the cover on the server.

Replace a REM Card 4620A When the REM Battery Is Installed on the Motherboard

1. Disconnect the REM card battery cable from the motherboard.
2. Remove the existing REM card by sliding the card at an angle out of the support bracket.
3. Reconnect the battery cable to the motherboard and the new REM card.
4. Replace the REM card by sliding it at an angle into the support bracket, then pressing it carefully into its connector.
5. Install the cover on the server.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

PARTS NOTE:

REFERENCE INFORMATION:

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.