Solution Type Technical Instruction Sure Solution 1319788.1 : How to Replace a REM Battery in a X6270:ATR:2304:0
In this Document
Applies to:Sun Blade X6270 Server Module - Version: Not ApplicableInformation in this document applies to any platform. GoalHow to remove and replace a RAID Expansion Module Battery in a Sun Blade X6270 Server Module
SolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) Field Engineer skills DELIVERY REQUIREMENT: Schedule with maintenance window Estimate AP Duration = 0.5 hours FIELD ENGINEER INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : WHAT ACTION DOES THE ENGINEER NEED TO TAKE: Replace a REM Battery on the REM Card 1. Remove the cover from the server. 2. Disconnect the REM cable and remove the REM card from the chassis. 3. Remove the REM battery from the REM card by removing the four screws securing the old REM battery to the card. 4. Attach the new battery to the REM card with four screws. 5. Install the cover on the server. Replace a REM Battery on the Motherboard 1. Remove the cover from the server. 2. Remove the two screws securing the battery to the bracket (see FIGURE 3-16). 3. Place the new battery on bracket and attach it using the two screws. 4. Plug the battery cable into the motherboard. 5. Install the cover on the server. OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: PARTS NOTE: REFERENCE INFORMATION: Service Manual: http://download.oracle.com/docs/cd/E19658-01/