Solution Type Technical Instruction Sure Solution 1319385.1 : SL500 - How to Change CAP From I/O to Storage Cell Function
In this Document
Applies to:Sun StorageTek SL500 Modular Library System - Version: Not ApplicableInformation in this document applies to any platform. GoalSL500 - How to Change CAP From I/O to Storage Cell FunctionSolutionTo change the function of the CAP (Cartridge Access Port) from I/O (Input/Output) operation to Storage cells, the following must be done:Log in to CLI port. Enter the command: cap x io or storage (x = module number) Example: cap 1 storage cap 1 io A reboot of the SL500 is needed to enable the change. The default of the CAP is I/O. A Field Service Representative is required to enable this function. It is not available via SL Console. Refer to the SL500 Installation Manual, Chapter 4, Configuring the Library, for command information. Attachments This solution has no attachment |
||||||||||||
|