Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1316491.1
Update Date:2011-04-28
Keywords:

Solution Type  Technical Instruction Sure

Solution  1316491.1 :   How to Remove and Replace a Sun Fire X4470 DVD Drive Filler Panel:ATR:1980:0  


Related Items
  • Sun Fire X4470 Server
  •  
Related Categories
  • GCS>Sun Microsystems>CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Fire X4470 Server - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Goal

How to Remove and Replace a Sun Fire X4470 DVD Drive Filler Panel

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Basic Sun hardware FE skills, familiarity or training for X4470 platform

DELIVERY REQUIREMENT:
Schedule with maintenance window

Estimate AP Duration = 0.5 hours

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

1. Attach an antistatic wrist strap.

When servicing or removing server components, attach an antistatic strap to your wrist and then to a metal area on the chassis.

2. Remove any media from the drive.

3. Power off the server.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Removing DVD Drive

1.1 Push down on the latch on the top left corner of the DVD drive or filler panel.

1.2 Slide the DVD drive or filler panel out of the server.(you should replace with another DVD drive or filler panel; otherwise server might overheat due to improper airflow)

2. Installing DVD Drive

2.1 Unpack the DVD drive or filler panel (If it is a DVD drive, place it on an antistatic mat)

2.2 Slide the DVD drive or filler panel into the front of the chassis until it seats.

3. Return the server to operation

3.1 Power on the server.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Restart system and have the System administrator verify functionality of system.

PARTS NOTE:

REFERENCE INFORMATION:

X4470 Service Manual: 
http://download.oracle.com/docs/cd/E19694-01/E21739-01/z400085b1296702.html
Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.