  Goal
  Solution


Applies to:

Sun Fire X4100 Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun Fire X4100 M2 Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Goal

How To Remove and Replace X4100 LED Switch Board

Solution

*DISPATCH INSTRUCTIONS*

WHAT SKILLS DOES THE ENGINEER NEED

Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner

DELIVERY REQUIREMENT

Schedule within contractual terms

ESTIMATE AP DURATION:

45 Minutes

*FIELD ENGINEER INSTRUCTIONS*

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is a wise precaution
System needs to be shutdown by customer

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Note: LED switch board is known as Front Panel Indicator Board in the Maintenance Manual

1. Power off the server
2. Disconnect all power cables and disconnect any external cables from the front I/O board's USB connectors
3. Remove the top cover
-Press down on the cover release button and, using the indent for leverage, slide the main cover toward the rear of the chassis approximately 0.5 inch
-Grasp the cover by its rear edge and lift it straight up from the chassis
4. Remove the front bezel
-Open the fan bay door and use a No. 2 Phillips screwdriver to unfasten the captive screw that locks the bezel in place
-Pull the bezel away from the chassis
5. Remove the front cover
-Open the door to the fan bay
-While holding the fan bay door open, slide the front cover toward the front of the chassis approximately 0.25 inch
-Raise the rear edge of the cover first, and then lift it off the chassis
6. Remove the front panel indicator board
-Unfasten the two screws that secure the front panel indicator board to the chassis
-While supporting the indicator board with your right hand, use your left hand to gently push the indicator board toward the center of the chassis to disconnect it from the front I/O board
7. Installation is the reverse of this procedure. When reinstalling screws, tighten to 7 in-lbs (0.8 Nm) using an adjustable torque driver

Note: remove disk 2 and 3 if present to re-install front cover

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE

None

PARTS NOTE

N/A