Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1310082.1 : How to Replace a V445 Crypto Card:ATR:1107:0
In this Document
Applies to:Sun Fire V445 Server - Version: Not ApplicableInformation in this document applies to any platform. GoalHow to remove and replace a Sun Fire V445 Crypto Card
SolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) No specific skills required DELIVERY REQUIREMENT: Schedule for immediate delivery within contractual terms. TIME ESTIMATE: 30 mis FIELD ENGINEER INSTRUCTIONS PROBLEM OVERVIEW: Crypto Card Faulty WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution Customer should conduct an orderly software system shutdown Power down System & disconnect Power Cords WHAT ACTION DOES THE ENGINEER NEED TO TAKE: Follow standard ESD procedures to avoid Electrostatic Discharge 1. Power off the system. Caution - The board must not receive any electrical power while adjusting the jumper. 2. Remove the computer cover to get access to the jumper, which is located at the top middle of the board. 3. Place the jumper on pins 0 and 1 of the jumper block. Pins 0 and 1 are the pins closest to the top of the board. There are three sets of two pins. Place the jumper on the 0 and 1 pin set.This is done for Zeroizing the Hardware card Caution - The board does not function with the jumper on pins 0 and 1.Hardware Jumper Block Pins 4. Power on the system. Caution - When you power on the system after adjusting the hardware jumper, all firmware, key material, and configuration information is deleted. This process returns the board to the factory state and places the board in Failsafe mode. 5. Power off the system. 6. Remove the jumper from pins 0 and 1 of the jumper block and store the jumper in the original location. Note - You can safely store the jumper on pins 3 and 5. This location does not affect any operation of the board 7. Replace the Crypto card with working card 8. Power on the system. 9. Connect to the Sun Crypto Accelerator board with scamgr. scamgr prompts you for a path to upgrade the firmware. 10. Type /opt/SUNWconn/cryptov2/firmware/sca6000fw as the path for installing the firmware. The firmware is automatically installed and you are logged out of scamgr. 11. Reconnect to Sun Crypto Accelerator 6000 board with scamgr. scamgr prompts you to either initialize the board with a new keystore, or initialize the board to use an existing keystore. OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Boot the system and start the application as per the sys admin procedure PARTS NOTE: REFERENCE INFORMATION: Sun Fire V445 Server Service Manual. http://download.oracle.com/docs/cd/E19088-01/ Sun Crypto Accelerator 6000 Board User's Guide for Version 1.1 http://download.oracle.com/docs/cd/E19321-01/ Attachments This solution has no attachment |
||||||||||||
|