Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1310025.1
Update Date:2011-04-12
Keywords:

Solution Type  Technical Instruction Sure

Solution  1310025.1 :   How to Replace a T5120/T5220 Battery Module on HW RAID PCI Card:ATR:1294:0  


Related Items
  • Sun SPARC Enterprise T5120 Server
  •  
  • Sun SPARC Enterprise T5220 Server
  •  
Related Categories
  • GCS>Sun Microsystems>CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun SPARC Enterprise T5120 Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun SPARC Enterprise T5220 Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Goal

How to remove and replace a T5120/T5220 Battery Module on HW RAID PCI Card

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)

Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner is required.

DELIVERY REQUIREMENT:

Schedule for immediate replacement can be planned within contractual terms.

TIME ESTIMATE: 1H

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:

Battery Module on HW RAID PCI Card Failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The customer should conduct an orderly software system shutdown. Then power down the system and disconnect the Power Cord.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1) Remove a Battery

1. Remove PCIe/XAUI riser 2.

2. Using a No. 1 flat-blade screwdriver, press the latch and remove the battery from the motherboard.

2) Install a Battery

1. Unpack the replacement battery.

2. Press the new battery into the battery holder on the motherboard.

3. Install PCIe/XAUI riser 2.

4. Use the ILOM setdate command to set the day and time.

5. After returning the server to operation, check and reset the Solaris OS date.

OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:

Part location

REFERENCE INFORMATION:

Sun SPARC Enterprise T5120 and T5220 Servers Service Manuals -
http://download.oracle.com/docs/cd/E19839-01/