Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1309981.1 : How to replace a V245 HBA Card:ATR:1244:0
In this Document
Applies to:Sun Fire V245 Server - Version: Not ApplicableInformation in this document applies to any platform. GoalHow to replace a V245 HBA CardSolution*DISPATCH INSTRUCTIONS*WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) No specific skills required DELIVERY REQUIREMENT: As scheduled *FIELD ENGINEER INSTRUCTIONS* PROBLEM OVERVIEW: Faulty HBA Card WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. The customer should conduct an orderly software system shutdown. WHAT ACTION DOES THE ENGINEER NEED TO TAKE: 1. Power off the server 2. Remove the rear cover 3. Disconnect any external cables attached to the faceplate and any internal cables connected to the PCI card internal connectors 4. Release the latch securing the PCI card to the chassis 5. Pull the PCI card from its slot Removal of a long PCI card might require you to remove the air baffle 6. Place the PCI card on an antistatic mat 7. Installation is the reverse of this procedure WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Boot and check for full functionality Changing a HBA with an embedded WWN may require SAN re-configuration PARTS NOTE: REFERENCE INFORMATION: Service Manual. http://download.oracle.com/docs/cd/E19088-01/ TIME ESTIMATE: 30 Minutes Attachments This solution has no attachment |
||||||||||||
|