Goal

How to Remove and Replace a Sun Fire T2000 Rear Fan Tray


Video - ATR 1174 (4:09)

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner.

DELIVERY REQUIREMENT:
Schedule for immediate delivery within contractual terms.

FIELD ENGINEER INSTRUCTIONS


PROBLEM OVERVIEW:
faulty Rear Blower.

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The rear blower on the server is hot-swappable.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Gain access to the rear of the server where the faulty blower unit is located.

2. Release the cable management arm tab and swing the cable management arm out of the way so you can access the power supply.

3. Unscrew the two thumbscrews that secure the rear blower to the chassis.

4. Grasp the thumbscrews and slowly slide the blower out of the chassis, keeping the blower level as you remove it.

5. Unpackage the replacement blower.

6. Slide the blower into the chassis until it locks into the power connector at the front of the blower compartment

7. Tighten the two thumbscrews to secure the blower to the chassis.

8. Verify that the Rear Blower and Service Required LEDs are not lit.

9. Close the CMA, inserting the end of the CMA into the rear left rail bracket.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
N/A

PARTS NOTE:

Sun Fire T2000 Server Service Manual  , p/n 819-2548:

Sun SPARC Enterprise T2000 Server Service Manual , p/n 819-7989


N/A

TIME ESTIMATE:
1.5 hrs